Fig. 24: Main Bearing Cap Bolt Tightening Sequence
Courtesy of Mitsubishi Motor Sales of America, Inc.
CONNECTING ROD BEARINGS
1) Mark bearing cap and connecting rod for location. Remove
connecting rod cap and bearing. Install replacement bearing.
2) Ensure reference marks on rod cap and connecting rod are
aligned. Check bearing clearance using Plastigage method. Ensure
connecting rod moves freely on crankshaft. Check connecting rod side
play. See CONNECTING RODS table under ENGINE SPECIFICATIONS at end of
article.
CRANKSHAFT END PLAY
If end play is not within specification, inspect thrust
bearings and crankshaft. Replace thrust bearing or crankshaft to
obtain correct end play. See CRANKSHAFT, MAIN & CONNECTING ROD
BEARINGS table under ENGINE SPECIFICATIONS at end of article.
ENGINE OILING
ENGINE LUBRICATION SYSTEM
Oil pressure is provided by a rotor-type pump driven by
crankshaft. Pressure relief valve is located in oil pump body.
CRANKCASE CAPACITY
Montero & Pick-up oil capacity is 5.0 qts. (4.7L). Add .5 qt.\
(.4L) with filter replacement. Add .5 qt. (.4L) with oil cooler.
3000GT oil capacity is 4.2 qts. (4.0L). Add .5 qt. (.4L) with filter\
replacement. Add .5 qt. (.4L) with oil cooler.
\003
A/C -H EA TE R S YSTE M - M AN UAL
1991 M it s u bis h i M onte ro
1991 MANUAL A/C-HEATER SYSTEMS
Chrysler Motors, Mitsubishi
Chrysler Motors: Colt Vista, Ram-50
Mitsubishi: Montero, Pickup
* PLEASE READ THIS FIRST *
CAUTION: When discharging air conditioning system, use only approved
refrigerant recovery/recycling equipment. Make every attempt
to avoid discharging refrigerant into the atmosphere.
A/C SYSTEM SPECIFICATIONS
SPECIFICATIONS TABLE \
\
\
\
\
\
\
Compressor Type
Colt Vista & Montero .................... Nippondenso 10-Cyl.
Pickup & Ram-50 ............................... Sanden Scroll
Compressor Belt Deflection
Colt Vista ............................ 11/32-7/16" (8-11 mm)
Montero ............................. 21/64-3/8" (8.5-9.5 mm)
Pickup & Ram-50 .................... 21/64-25/64" (8.5-10 mm)
Compressor Oil Capacity
Colt Vista & Montero ............................... 2.7 ozs.
Pickup & Ram-50 .................................... 5.0 ozs.
Refrigerant (R-12) Capacity
Colt Vista & Montero ................................ 32 ozs.
Pickup & Ram-50 ..................................... 30 ozs.
System Operating Pressures (1)
Colt Vista, Pickup & Ram-50
High Side .................... 130-220 psi (9.1-15.5 kg/cm
)
Low Side ........................ 20-26 psi (1.4-1.8 kg/cm)
Montero
Dual Unit
High Side .................. 142-199 psi (9.9-14.0 kg/cm
)
Low Side ...................... 16-30 psi (1.1-2.1 kg/cm)
Single Unit
High Side ................... 102-142 psi (7.1-9.9 kg/cm
)
Low Side ...................... 18-32 psi (1.3-2.2 kg/cm)
(1) - With ambient temperature at least 80
F (27C). \
\
\
\
\
\
\
DESCRIPTION
Slight variations exist among the manual A/C-heater systems
used. Either Sanden Scroll or Nippondenso 10-cylinder compressor is
used. Cycling of the compressor clutch is controlled by switches which
monitor temperatures and pressures.
Compressors will only operate within the normal operating
temperatures and pressures set for each model. An electric condenser
fan operates whenever A/C system is operating. System components used
vary depending upon model. Most systems include an A/C compressor
control unit, fan switch, evaporator, temperature sensor, high and low
(or dual) pressure switch, engine coolant temperature switch,
compressor, condenser, receiver-drier and various pipes and hoses.
system is in operation. This high pressure could rupture can
or fitting at safety can valve, resulting in damage and
personal injury.
CONNECTING LINES & FITTINGS
A new "O" ring should be used in all instances when
connecting lines and fittings (dip "O" ring in clean refrigeration oil
and make certain it is not twisted during installation). Always use
two wrenches to avoid twisting or distorting lines and fittings,
tighten coupling nuts securely.
PLACING SYSTEM IN OPERATION
After component replacement and/or system servicing has been
completed and all connections have been made, proceed as follows:
1) Evacuate the system using a vacuum pump.
2) Charge the system with new R-12 (refrigerant) according t\
o
each individual vehicle as outlined in the
GENERAL COOLING SYSTEM SERVICING article. Also see Refrigerant
Capacity in this Section.
3) Leak test the system, with particular attention to all new
connections and components.
4) Make a performance test of the system. Never assume that a
recharging has automatically corrected a problem.
COMPRESSOR REMOVAL INFORMATION - ISOLATION METHOD
On systems which have compressors equipped with stem-type
service valves (Tecumseh), it is possible to isolate the compressor
for removal.
Isolating
Turn both high and low pressure manual valves to extreme
clockwise (front seat) position. Loosen cap on high pressure manual
valve connection to compressor and allow gas to escape until
compressor is relieved of pressure.
COMPRESSOR REMOVAL INFORMATION - DISCHARGE METHOD
This procedure is to be used on vehicles which have
compressor equipped with Schrader service valves. In these cases, the
compressor cannot be isolated and the system must be discharged, using
approved refrigerant recovery/recycling equipment, prior to compressor
removal.