\003
A/C C O M PR ESSO R O IL C HEC KIN G
1988 J e ep C hero ke e
A/C General Servicing
COMPRESSOR OIL CHECK
* PLEASE READ THIS FIRST *
CAUTION: When discharging air conditioning system, use only approved
refrigerant recovery/recycling equipment. Make every attempt
to avoid discharging refrigerant into the atmosphere.
ISOLATING COMPRESSOR - GRAND WAGONEER ONLY
1) Connect service gauge set to the compressor service valves
and open compressor valves slightly (turn clockwise). Start engine and\
operate air conditioning. Slowly turn compressor suction valve
clockwise toward closed (front-seated) position.
2) When suction pressure is reduced to zero or less, turn off
engine and compressor and quickly turn suction valve stem in to full
front-seated position. Suction pressure should be slightly above zero.
Turn discharge valve into front-seated position.
3) To check oil lever, slowly open crankcase plug to relieve
any remaining pressure. After oil level is correct, cap service gauge
parts on both valves. Back-seat suction service valve to allow
refrigerant to enter compressor. Open discharge valve halfway.
4) Loosen discharge service valve cap, allowing refrigerant
pressure to force air out of compressor. Back-seat service valve and
tighten cap. Compressor is now ready for operation.
REFRIGERANT OIL
Only new, pure, moisture-free refrigerant oil should be used
in the air conditioning system. This oil is highly refined and
dehydrated to a point where moisture content is less than 10 parts per
million. The oil container must be tightly closed at all times when
not in use, or moisture will be absorbed from the air and introduced
into the refrigeration system.
DISCHARGING SYSTEM
CAUTION: When discharging air conditioning system, use only approved
refrigerant recovery/recycling equipment. Make every attempt
to avoid discharging refrigerant into the atmosphere.
If compressor has stem-type service valves, it can be
isolated and removed without discharging entire system. Otherwise,
discharge system completely using approved refrigerant
recovery/recycling equipment before loosening any fittings.
DISCONNECTING LINES & FITTINGS
After system is discharged, carefully clean area around all
fittings to be opened. Always use 2 wrenches when tightening or
loosening fittings to avoid twisting or distorting lines. Cap or plug
all openings as soon as lines are removed. Do not remove caps until
immediately before connections are made. This will keep entry of air
and moisture to a minimum, reducing the chance of damage to
components.
\003
A/C -H EA TE R S YSTE M - M AN UAL
1988 J e ep C hero ke e
1988 Manual A/C-Heater Systems
JEEP
* PLEASE READ THIS FIRST *
CAUTION: When discharging air conditioning system, use only approved
refrigerant recovery/recycling equipment. Make every attempt
to avoid discharging refrigerant into the atmosphere.
DESCRIPTION
On Cherokee, Comanche and Wagoneer, the Climate Control
System is an integral assembly combining air conditioning, heating and
ventilating capabilities for models with air conditioning. The A/C
registers are built into instrument panel.
On Wrangler models, a dual flow unit with the capability of
recirculating air or drawing air from outside is used. It incorporates
under-dash registers and uses a blend-air type system.
The A/C components include a compressor, condenser, receiver-
drier, a sight glass (in the receiver-to-evaporator line) and
evaporator housing. Evaporator housing contains evaporator core,
expansion valve, thermostat, wiring and drain tube. Blower motor and
fan are located in blower housing, which is attached to evaporator
housing.
Vents provided in evaporator housing are adjustable to direct
air to different positions in vehicle's interior. System controls
include fan and temperature control knobs built into lower evaporator
housing assembly or temperature and mode levers on control panel
integrated with instrument panel.
OPERATION
A/C SYSTEM CONTROLS
Temperature & Fan Control Knobs
(Wrangler)
The right rotary control knob allows selection of desired
temperature. Knob has "OFF" "1", "2" and "3" positions for different
levels of cooling. The left rotary fan switch (knob) controls blower
motor speed. Knob has "OFF", "LOW", "MED" and "HI" positions. Fan will
operate unless mode control lever is in "OFF" position.
The A/C fan switch is a 3-speed unit used in conjunction with
a blower motor resistor. Fan switch controls low, medium and high
speed operation. Switch may be serviced by removing access plate
located on lower evaporator core housing, below control panel.
The A/C temperature control switch has a thermostat unit
built-in. Cooling adjustment is done by turning knob in a clockwise
rotation. For fast, efficient system operation in hot weather, vehicle
should be purged of hot air by driving about 2-3 city blocks with at
least one window open. During this time, temperature control knob
should be rotated clockwise to "MAX" position and fan control knob
placed in "HI" position. This allows evaporator to pre-cool and avoid
typical first blast of warm air.
Temperature Control Panel
(Cherokee, Comanche & Wagoneer)
The upper temperature control (mode) lever includes "MAX",
"NORM", "BI-LEVEL", "VENT", "HEAT" and "OFF" positions. At the far end
Bracket broken, affecting
performance ............ A ............ Require replacement.
Bracket broken, not
affecting performance .. .. ........ No service suggested or
required.
Bracket corroded,
affecting performance .. A .. Require repair or replacement.
Bracket corroded, not
affecting performance .. 2 .. Suggest repair or replacement.
Bracket cracked, affecting
performance ............ A .. Require repair or replacement.
Bracket cracked, not
affecting performance .. 1 .. Suggest repair or replacement.
Bracket holes elongated,
affecting performance .. A .. Require repair or replacement.
Bracket holes elongated,
not affecting
performance ............ .. ........ No service suggested or
required.
Bracket loose, affecting
performance ............ A .. Require repair or replacement.
Bracket loose, not
affecting performance .. 1 .. Suggest repair or replacement.
Bracket missing ......... C ............ Require replacement.
Housing broken, affecting
performance ............ A .. Require repair or replacement.
Housing broken, not
affecting performance .. .. ........ No service suggested or
required.
Housing cracked, affecting
performance ............ A .. Require repair or replacement.
Housing cracked, not
affecting performance .. 1 .. Suggest repair or replacement.
Inoperative ............. A ........... (1) Require repair or
replacement.
Leaking ................. A .. Require repair or replacement.
Noisy ................... 2 ........... ( 2) Suggest repair or
replacement.
Threads damaged ......... A .. Require repair or replacement.
Threads stripped (threads
missing) ............... A ............ Require replacement.
Tubing connection
leaking ................ A .. Require repair or replacement.
( 1) - Inoperative includes intermittent operation or out of
OEM specification.
( 2) - Compressor noise can also be caused by low oil level,
state of charge, air contamination, or type of
refrigerant.
\
\
\
\
\
\
\
CONDENSER AIR SEALS
CONDENSER AIR SEAL INSPECTION \
\
\
\
\
\
\
Condition Code Procedure
Leaking ................. A . Require repair or replacement.
Missing ................. C ........... Require replacement.
\
\
\
\
\
\
\
CONDENSER FAN MOTORS
missing ................ C .......... Require replacement of
hardware.
Attaching hardware not
functioning ............ A ... Require repair or replacement
of hardware.
Contaminated, affecting
performance ............ A ............ Require replacement.
Dessicant bag
deteriorated ........... A ........ (1) Require replacement.
Further inspection required.
Dessicant at the end of
its useful life (saturated
with moisture) ......... 1 .. Suggest repair or replacement.
Fusible plug leaking .... A .... Require replacement of plug.
Leaking ................. A ............ Require replacement.
Pressure relief device
leaking ................ A . Require replacement of pressure
relief device.
Restricted .............. A .. Require repair or replacement.
Sight glass no longer
transparent ............ 2 ... Suggest replacement of drier.
Threads damaged ......... A .. Require repair or replacement.
Threads stripped (threads
missing) ............... A ............ Require replacement.
Tubing connection
leaking ................ A .. Require repair or replacement.
( 1) - Inspect system to determine effects of dessicant bag
deterioration.
\
\
\
\
\
\
\
REFRIGERANT
NOTE: Refrigerants include any SNAP (Significant New Alternative
Policy)-approved blends.
REFRIGERANT INSPECTION
\
\
\
\
\
\
\
Condition Code Procedure
Contaminated (other than
refrigerant blends) .... B ........ Require service to remove
contamination.
Different types of
refrigerants in the same
system (other than
refrigerant blends) .... B ................. Require repair.
Overcharged ............. B ................. Require repair.
Refrigerant type
does not match
fittings and label ..... B ................. Require repair.
Undercharged ............ B ................. Require repair.
\
\
\
\
\
\
\
REFRIGERANT OIL
REFRIGERANT OIL INSPECTION \
\
\
\
\
\
\
Condition Code Procedure
Contaminated ............ 1 .. Require repair or replacement.
Overfilled .............. B ................. Require repair.