Page 148 of 816
1482-2. Charging
Prius Plug-in Hybrid_OM_OM47D72E_(EE)
NOTICE
■When inserting the charging connector
Observe the following precautions. Failure to do so may cause a malfunc-
tion in the charging connector locking system.
● Check that the charging connector is compatible with this vehicle
A charging connector of the different type or a charging connector with
damaged or deformed insertion part may not be locked.
● Do not operate the charging connector lock switch before the charging
connector is connected
● Do not apply excessive force to the charging connector after the charging
connector is inserted
When removing the charging connector, make sure to unlock the charging
connector.
Page 149 of 816

149
2
2-2. Charging
Plug-in hybrid system
Prius Plug-in Hybrid_OM_OM47D72E_(EE)
Power sources that can be used
●Connect to an AC 220 V - 240 V socket with a Residual Current Cir-
cuit-Breaker (RCCB) and a circuit breaker. Use of a 13A individual
circuit is strongly recommended to ensure charging cable will oper-
ate properly.
● We strongly recommend that you use an exclusive connection from
the junction box for charging.
If you connect on a socket that is on a shared circuit, and other
electrical appliances are used on other sockets on the same circuit,
then the circuit breaker might trip.*
● Ensure that the junction box is equipped with a Residual Current
Circuit-Breaker (RCCB). If it is not, have one installed by a duly
qualified professional.
● When charging outdoors, make sure to connect to a rain-tight
socket that is certified for outdoor use.
Checking Residual Current Circuit-Breaker (RCCB) operation
before its use is recommended.
● Check whether there are any local EV-charging regulations in
place, and adhere to them.
*: For detailed information, consult an electrician.
An external power source that fulfills the following criteria is
necessary for charging this vehicle. Confirm this before
charging.
WARNING
■ Warnings for electrical faults
Make sure to observe the precautions in this Owner’s Manual when
charging the vehicle.
Failure to use a power source that fulfills the requirements, or failure to
observe regulations while charging could lead to an accident, possibly
resulting in death or serious injury.
Power sources
Page 150 of 816

1502-2. Charging
Prius Plug-in Hybrid_OM_OM47D72E_(EE)
■The charging environment
For safe charging, the following charging equipment and settings are recom-
mended.
●Rain-tight socket
When charging outdoors, connect the plug to a rain-tight socket, and ensure
that the plug remains waterproof while the plug is connected.
●Dedicated circuit
• To reduce the risk of fire, connect only to an at least 13A branch circuit
with an over-current protection.
• To reduce the risk of electric shock when working with the plug, connect
to a socket that has a Residual Current Circuit-Breaker (RCCB) installed.
●Remote switch
Allows the electricity from the socket to be interrupted by operating a switch,
thus allowing safe removal and insertion of the plug on rainy days.
■When your circuit breaker trips during charging
The upper limit of the charging current can be changed in the “Vehicle Set-
tings” settings on the multi-information display.
Press or of the meter control switches to select (“Vehicle
Settings”) in the screen, and then press .
Press or of the meter control switches to select “Charge Settings”,
and then press .
The “Charge Settings” screen will display.
Press or of the meter control switches to select “Charge Current”,
and then press .
The “Charge Current” screen will display.
Press or of the meter control switches to select “8A”, and then
press .
The maximum charging current during charging will be restricted to 8A.
*
If the breaker still trips while charging, even after changing the upper limit of
the charging current, check if the connected power source meets the speci-
fied charging conditions. (P. 149)
*: Restricting the charging current will lengthen the charging time.
1
2
3
4
Page 151 of 816

1512-2. Charging
2
Plug-in hybrid system
Prius Plug-in Hybrid_OM_OM47D72E_(EE)
WARNING
■Power sources precautions
Observe the following precautions.
If you do not follow them, fire, electrical shock and/or damages may occur,
possibly resulting in death or serious injury.
● Connect to an AC 220 V - 240 V socket with a Residual Current Circuit-
Breaker (RCCB) and supplied by a circuit breaker in line with local regula-
tions. Use of an individual circuit provi ded with at least 13A is strongly rec-
ommended.
● Use of a block heater socket which fails to meet the requirements is pro-
hibited for charging.
● Make sure to connect the charging connector and charging inlet directly.
Do not connect a converting adaptor or extension cord between the
charging connector and charging inlet.
● Do not connect the charging cable to a
multi-socket adaptor, multi-plugs, or
conversion plug.
● Connecting the charging cable to an
extension cord is strictly prohibited. The
extension cord may overheat and does
not contain a Residual Current Circuit-
Breaker (RCCB).
The leakage detection function of the
CCID (Charging Circuit Interrupting
Device) may not operate correctly.
● Do not connect to a power strip.
Page 152 of 816

1522-2. Charging
Prius Plug-in Hybrid_OM_OM47D72E_(EE)
Charging methods
◆Charging from an external power source (P. 165)
This is a charging method used when charging from an AC socket
(220 V-240 V) with the charging cable equipped to the vehicle or
charging at a public charging station.
The charging start time (or departure time) and day can be set to carry
out charging using the charging schedule at the desired date and time.
(P. 176)
◆Using the hybrid battery (traction battery) charge mode
(P. 9 9 )
The plug-in hybrid system can be switched to hybrid battery (trac-
tion battery) charge mode to charge the hybrid battery (traction bat-
tery) using electricity generated by gasoline engine operation.
The maximum charge amount in the hybrid battery (traction battery)
charge mode is approximately 80% of the fully charged capacity for the
charging from an external power source.
◆Solar charging system (if equipped) (P. 188)
In certain conditions, when the vehicle is parked, the hybrid battery
(traction battery) can be charged by using electricity generated by
the solar panel equipped to the roof of the vehicle.
The maximum charge amount of the solar charging system is approxi-
mately 90% of the fully charged capacity for the charging from an exter-
nal power source. (This does not mean the battery can be fully charged
in one day.)
The following methods can be used to charge the hybrid battery
(traction battery).
Page 153 of 816
1532-2. Charging
2
Plug-in hybrid system
Prius Plug-in Hybrid_OM_OM47D72E_(EE)
The time required to charge the hybrid battery (traction battery) differs
according to the charging voltage and charging current.
*1: The charging voltage may differ depending on the target region.
*2: This is the maximum value. Furthermore, the upper limit of the charging
current can be changed in the “Vehicle Settings” settings. (P. 150)
*3: The time required for charging to complete depends on conditions such as
the remaining charge of the hybrid battery (traction battery), the outside
temperature and specifications of a charger (charging station).
Estimated charging time
Connected power
sourceCharging
station
Home power source
Except for
France,
Finland and
SwitzerlandFor France,
Finland and
Switzerland
Charging voltage*1AC 230 VAC 230 VAC 230 V
Charging current*216A10A8A
Estimated charging
time
*3Approximately
2 hoursApproximately
3 hours 10 min-
utesApproximately
3 hours 50 min-
utes
Page 154 of 816

1542-2. Charging
Prius Plug-in Hybrid_OM_OM47D72E_(EE)
■Charging time may increase
In the following situations, charging time may become longer than normal:
●In very hot or very cold temperatures.
●The vehicle is consuming a lot of electricity, for example, when the head
light switch is on etc.
●There is a power outage during charging.
●There is an interruption in the electrical supply.
●There is a drop in the voltage of external power source.
●The charge in the 12-volt battery is low, for example due to the vehicle being
left unused for a long period of time.
●The maximum charging current is set to 8A through the “Vehicle Settings”
settings. (P. 150)
●When the “Traction Battery Heater” operates.
●When the “Traction Battery Cooler” is operated before charging. (if
equipped) (P. 155)
●When the plug generates heat due to a loose socket connection etc.
■Using a DC Charger
DC Chargers cannot be used with this vehicle.
This vehicle is equipped with several functions that are linked with
charging.
■“Traction Battery Heater”
When the outside temperature is low and the charging cable is con-
nected to the vehicle, this function automatically warms the hybrid
battery (traction battery) until it reaches or exceeds a certain tem-
perature.
●When the charging cable is removed from the vehicle or remains
connected to the vehicle for approximately 3 days, the system
automatically stops.
●When the charging schedule is used (P. 176), this function will
operate according to the charging schedule.
Charging-linked functions
Page 155 of 816

1552-2. Charging
2
Plug-in hybrid system
Prius Plug-in Hybrid_OM_OM47D72E_(EE)
■“Traction Battery Cooler” (if equipped)
When the hybrid battery (traction battery) is hot, this function pro-
tects it by using the vehicle air conditioning to cool it before
charging is carried out.
When the hybrid battery (trac-
tion battery) is above a certain
temperature and the power
switch is turned off, a check
screen is displayed on the
multi-information display that
indicates whether “Traction Bat-
tery Cooler” is implemented.
When “No” is selected, the hybrid battery (traction battery) cooling sys-
tem does not operate.
■“Traction Battery Heater”
●“Traction Battery Heater” may operate when charging is not being per-
formed.
●When “Traction Battery Heater” is operating, the charging indicator illumi-
nates.
●When “Traction Battery Heater” is operating during charging, the charging
time may be longer than normal.
●If the outside temperature becomes high while “Traction Battery Heater” is
operating, charging may complete earlier than the “Departure” time set.
(P. 176)
●“Traction Battery Heater” can be turned on and off in the “Vehicle Settings”
settings on the multi-information display. (P. 782)
●“Traction Battery Heater” may operate even when the hybrid battery (trac-
tion battery) is fully charged depending on the temperature of the hybrid bat-
tery (traction battery).
• The remaining charge of the hybrid battery (traction battery) decreases
when “Traction Battery Heater” operates. The charging operation may
start again to charge the hybrid battery (traction battery).
• “Charging Stopped Due to Pulled Charging Connector” may be shown
when the charging connector is removed while recharging. (P. 197)