SPECIFICATIONS
Dimensions:Overall length:2070 mm (81.5 in)
Overall width: 1230 mm (48.4 in) (YFM70GPAK, YFM70GPHK,
YFM70GPXK)
1250 mm (49.2 in) (YFM70GPLK)
Overall height: 1253 mm (49.3 in) (YFM70GPAK, YFM70GPHK,
YFM70GPXK)
1270 mm (50.0 in) (YFM70GPLK)
Seat height:
918 mm (36.1 in) (YFM70GPAK, YFM70GPHK,
YFM70GPXK)
930 mm (36.6 in) (YFM70GPLK)
Wheelbase: 1250 mm (49.2 in)
Ground clearance:
288 mm (11.3 in) (YFM70GPAK, YFM70GPHK,
YFM70GPXK)
300 mm (11.8 in) (YFM70GPLK)
Minimum turning radius: 3.7 m (12.14 ft)
Maximum water depth:
35 cm (14 in)
Weight:Curb weight:313.0 kg (690 lb) (YFM70GPXK)
318.0 kg (701 lb) (YFM70GPAK, YFM70GPHK)
342.0 kg (754 lb) (YFM70GPLK)Loading:Maximum loading limit:240.0 kg (530 lb)
(Total weight of rider, cargo, accessories, and tongue)Noise and vibration level:Noise level (77/311/EEC):78.0 dB(A) at 3125 r/min (YFM70GPAK,
YFM70GPHK_EUR/FRA/GBR,
YFM70GPXK_EUR/FRA/GBR)
79.0 dB(A) at 3125 r/min (YFM70GPLK)
Uncertainty of measurement:
0.5 dB(A) (YFM70GPLK)
0.6 dB(A) (YFM70GPAK, YFM70GPHK_EUR/FRA/GBR,
YFM70GPXK_EUR/FRA/GBR)
Vibration on seat (EN1032, ISO5008): Will not exceed 0.5 m/s² (YFM70GPAK,
YFM70GPHK_EUR/FRA/GBR, YFM70GPLK,
YFM70GPXK_EUR/FRA/GBR)
Uncertainty of measurement: 0.0 m/s² (YFM70GPAK, YFM70GPHK_EUR/FRA/GBR,
YFM70GPLK, YFM70GPXK_EUR/FRA/GBR)
UB4F60E0.book Page 1 Thursday, June 7, 2018 10:42 AM
10-6
10
Battery voltage warning light:LEDFuses:Main fuse:
40.0 A
Headlight fuse: 10.0 A
Signaling system fuse: 10.0 A
Ignition fuse:
10.0 A
Auxiliary DC jack fuse: 10.0 A
Fuel injection system fuse: 15.0 A
Four-wheel-drive motor fuse:
10.0 A
Radiator fan motor fuse: 20.0 A
EPS fuse: 40.0 AEBU30403Noise and vibration levels statement (for Eu-
rope)
The figures quoted are emission levels and are not
necessarily safe working levels. Whilst there is a
correlation between the emission and exposure
levels, this cannot be used reliably to determine whether or not further precautions are required.
Factors that influence the actual level of exposure
of work-force include the characteristics of the
work room, the other sources of noise, etc. i.e. the
number of machines and other adjacent process-
es, and the length of time for which an operator is
exposed to the noise. Also the permissible expo-
sure level can vary from country. This information,
however, will enable the user of the machine to
make a better evaluation of the hazard and risk.UB4F60E0.book Page 6 Wednesday, April 25, 2018 11:52 AM