2018 INFINITI Q50 HYBRID ignition

[x] Cancel search: ignition

Page 16 of 44

INFINITI Q50 HYBRID 2018  First responder´s Guide 2-6 High-voltage Circuit Shut-Off System
This
vehicle is equipped with a system to shut off the current from the high-voltage battery by the following
methods: Service plug
Positioned in the center ar

Page 22 of 44

INFINITI Q50 HYBRID 2018  First responder´s Guide Powering Down the High-voltage System
The
high-voltage system can be shut down with any 1 of the following procedures:• Turn OFF the power switch and disconnect the 12-volt battery. Refer to Primary

Page 28 of 44

INFINITI Q50 HYBRID 2018  First responder´s Guide Alternate Procedure 2 (Remove Service Plug)
DANGER
• Do not remove the service plug without always wearing appropriate Personal
Protective Equipment (PPE) to help protect the responder from serious

Page 31 of 44

INFINITI Q50 HYBRID 2018  First responder´s Guide 9. Remove the service plug (A) by pulling the locking lever (B) , then pressing the locking tab (C)
and rotating the handle (D) fully outward. Using the handle, pull the service plug (E) completely
ou

Page 32 of 44

INFINITI Q50 HYBRID 2018  First responder´s Guide 3-3.3 Vehicle Fire
• Always utilize full Personal Protective Equipment (PPE) and self-contained breathing
apparatus during fire fighting operations. Smoke from a Q50 HYBRID vehicle fire is
similar t