2018 INFINITI Q50 HYBRID battery

[x] Cancel search: battery

Page 14 of 44

INFINITI Q50 HYBRID 2018  First responder´s Guide The following warning label is applied to the high-voltage battery located inside the luggage compartment.
2-5
High-voltage Safety System
The high-voltage safety system is intended to help keep vehicl

Page 15 of 44

INFINITI Q50 HYBRID 2018  First responder´s Guide • The high-voltage system and high-voltage capacitor may remain powered for up to
approximately 10 minutes after the vehicle is shut off. Personal Protective Equipment
(PPE) must always be worn when

Page 16 of 44

INFINITI Q50 HYBRID 2018  First responder´s Guide 2-6 High-voltage Circuit Shut-Off System
This
vehicle is equipped with a system to shut off the current from the high-voltage battery by the following
methods: Service plug
Positioned in the center ar

Page 18 of 44

INFINITI Q50 HYBRID 2018  First responder´s Guide Preparation Items
SpecificationPurpose
Leather
gloves Must be able to fasten tight
around

the wrist. (Worn over
insulated gloves) To protect insulated gloves.
Wrenches Size:10mm
To remove the 12-volt

Page 20 of 44

INFINITI Q50 HYBRID 2018  First responder´s Guide 3-3 How to Handle a Damaged Vehicle at an Accident Scene
NO
TE:
If any air bags have deployed in the following 3 situations, the high-voltage (HV) system has
been designed to automatically shut off at

Page 21 of 44

INFINITI Q50 HYBRID 2018  First responder´s Guide 3-3.1 High-voltage System Shut-Down Procedure
Any
of the following procedures can shut down the high-voltage system. The first response operation
should only begin after shutting down the high-voltage

Page 22 of 44

INFINITI Q50 HYBRID 2018  First responder´s Guide Powering Down the High-voltage System
The
high-voltage system can be shut down with any 1 of the following procedures:• Turn OFF the power switch and disconnect the 12-volt battery. Refer to Primary

Page 24 of 44

INFINITI Q50 HYBRID 2018  First responder´s Guide 6. Open the 12-volt battery service access cover.
7.
Disconnect negative (-) battery cable and cover it with
insulated tape.
8. Wait approximately ten (10) minutes for complete discharge of the high-v