Page 22 of 56

Powering Down the High-voltage System
The
high-voltage system can be shut down with any 1 of the following procedures:• Turn OFF the power switch and disconnect the 12-volt battery. Refer to Primary Procedure
(DG–22) .
•
Remove the fuse for the high-voltage control system and disconnect the 12-volt battery.
Refer to Alternate Procedure 1 (Disconnect Underhood Fuse Panel) (DG–25).
•
Remove the service plug and disconnect the 12-volt battery. Refer to Alternate Procedure 2
(Remove
Service Plug) (DG–28) .
Primary
Procedure
NOTE:
Before disconnecting the 12-volt battery terminal, if necessary, lower the windows, adjust
the steering column, adjust the seats, unlock the doors, etc. Once 12-volt battery is
disconnected, power controls will not operate.
1. If possible, check the READY indicator status in the instrument cluster. If it is on, the high-
voltage
system is active.
2. Place the shift selector in the Park (P) position.
3. Push the ignition switch once to turn OFF the high- voltage system. Verify that the READY indicator is off
and then continue to the next steps to open the trunk
for 12-volt battery negative cable access.
If the READY indicator does not turn off, refer to
Alternate Procedure 1 (Disconnect Underhood Fuse
Panel)
(DG–25)
4. If possible, keep the Infiniti Intelligent Key at least 5
meters (16 feet) away from the vehicle (except to
open the trunk as noted below) . AAYIA0191ZZ
LOCK
ACC
(OFF)
ON
AAYIA0192ZZ
AAYIA0068ZZ
DG–22
Page 24 of 56
NOTE:
If
the electrical release does not work, the trunk will have to be forced open.
6. Open the 12-volt battery service access cover.
7. Disconnect negative (-) battery cable and cover it withinsulated tape.
8. Wait approximately ten (10) minutes for complete discharge of the high-voltage capacitor
after the battery cable has been disconnected.
9. Perform the dismantling operation. Refer to 6. Dismantling Information (DG–42). AAYIA0195ZZ
AAYIA0196ZZ
DG–24
Page 25 of 56
Alternate Procedure 1 (Disconnect Underhood Fuse Panel)
NO
TE:
Before disconnecting the underhood fuse panel and the negative (-) battery cable,
if necessary, lower the windows, adjust the steering column, adjust the seats, unlock the
doors, etc. Once the underhood fuse panel and negative (-) battery cable are disconnected,
power controls will not operate.
1. Pull release handle (1) and pull up release lever (2) to open the hood.
2. Remove clips (A) and RH hood ledge cover (1) .NOTE: : Arrow in illustration depicts vehicle front
direction.
3.
Remove clips (A) and RH cowl cover (1) . TGAAYIA0009ZZ
AAYIA0207ZZ
AAYIA0208ZZ
DG–25
Page 27 of 56
b. trunk button on the Infiniti Intelligent Key
[press for longer than one (1) second].
c. trunk open request switch (located above license plate)*.
* You must have the Infiniti Intelligent Key within
approximately 1 meter (3 feet) range of trunk
request switch to use the trunk open
request switch function.
NOTE:
If the electrical release does not work, the
trunk will have to be forced open.
8. Open the 12-volt battery service access cover.
9. Disconnect negative (-) battery cable and cover it with insulated tape.
10. Wait approximately ten (10) minutes for complete discharge of the high-voltage capacitor
after the fuse panel and battery cable have been disconnected.
11. Perform the dismantling operation. Refer to 6. Dismantling Information (DG–42). AAYIA0068ZZ
AAYIA0194ZZ
AAYIA0195ZZ
AAYIA0196ZZ
DG–27
Page 28 of 56

Alternate Procedure 2 (Remove Service Plug)
DANGER
• Do not remove the service plug without always wearing appropriate Personal
Protective Equipment (PPE) to help protect the dismantler from serious injury or death
by electrical shock.
• Immediately cover the service plug socket with insulated tape. The high-voltage
battery
retains high-voltage power even when the service plug is removed. To avoid
electric shock, NEVER touch the terminals inside the socket. To avoid unintended reinstallation and risk of electrical shock and severe personal injury
or
death, the dismantler should carry the service plug on his/her person while work is in
progress.
NOTE: Before disconnecting the 12-volt battery terminal, if necessary, lower the windows, adjust
the steering column, adjust the seats, unlock the doors, etc. Once 12-volt battery is
disconnected, power controls will not operate.
1. If possible, check the READY indicator status in the instrument cluster. If it is on, the high-
voltage
system is active.
2. Place the shift selector in the Park (P) position.
3. Push the ignition switch once to turn OFF the high- voltage system. Then verify whether the READY indicator
is off.
If the READY indicator does not turn off, continue to
step 4. AAYIA0191ZZ
LOCK
ACC
(OFF)
ON
AAYIA0192ZZ
DG–28
Page 30 of 56
c. trunk open request switch (located above
license plate)*. Method
Shift Selector Position Ignition Switch Status
a
P or N Any
b POFF
c* Any Any
* You must have the Infiniti Intelligent Key within approximately 1 meter (3 feet) range of trunk request switch
to use the trunk open request switch function.
NOTE:
If the electrical release does not work, the trunk will have to be forced open.
6. Open the 12-volt battery service access cover.
7. Disconnect negative (-) battery cable and cover it withinsulated tape. AAYIA0194ZZ
AAYIA0195ZZ
AAYIA0196ZZ
DG–30
Page 32 of 56

3-4.2 Cutting the Vehicle Body
DANGER
• Do not cut into high-voltage related areas to avoid severe personal injury or death.
• Do not cut into the high-voltage battery to avoid severe personal injury or death.
• When removing parts, NEVER touch the high-voltage parts or the insides of the
exposed orange-colored high-voltage cables to avoid severe personal injury or
death. Appropriate Personal Protective Equipment (PPE) must always be worn when
touching or working on high-voltage components. To avoid unintended reinstallation and risk of electrical shock and severe personal injury or
death,
the dismantler should carry the fuses or service plug on his/her person while work
is in progress. Do not cut air bag parts to avoid unintended deployment of the air bags and the risk of
severe
personal injury or death.
If approximately (10) minutes have passed since the dismantler shut down the high-voltage system
[refer to 3-4.1 High-voltage System Shut-Down Procedure (DG–21)], then the dismantler can cut the
vehicle
except for the high-voltage battery. DO NOT cut the high-voltage battery due to possible electrocution risk and electrolyte solution
leakage.
DG–32
Page 33 of 56

SRS Air Bag System Components Location
The
SRS air bag system must not be cut as there is a risk of short circuit and unintentional deployment of
the SRS However, the vehicle can be cut (except inflators) under the following conditions: • The front, side and curtain air bags have deployed.
• At least three (3) minutes have passed after the 12-volt battery negative (-) cable has beendisconnected and the high-voltage system has been shut down.
1. Crash zone sensor (located
underhood near hood latch) 2. Supplemental front air bag
modules (Infiniti Advanced Air
Bags)3. Front seat-mounted side-
impact supplemental air bags
4. Roof-mounted curtain side-
impact supplemental air bags 5. Roof-mounted curtain side-
impact supplemental air bag
inflators6. C-pillar satellite sensors
(LH shown, RH similar)
7. Seat belt buckle pretensioners 8. Seat belts with pretensioners 9. B-pillar satellite sensors
10. Air bag control unit (ACU) 11. Front door satellite sensors (LH shown, RH similar) 21
10 4 53
8 7 6
9
11
AAYIA0189ZZ
DG–33