c. The charge connector can be unlocked by
pushing the charge connector unlock button on
the Nissan Intelligent Key® for more than
1 second. The charge connector will temporarily
unlock for 30 seconds.
d. Press the charge connector release button and pull the charge connector to remove it.
3. If the Trickle or Normal Charge Connector Cannot Unlock
a. Place power switch in OFF position.
b. Open the hood.
c. Using a flat head screwdriver (or suitable tool) , insert into the screw located through the access
hole near the front of the hood lock.
d. Rotate screw clockwise to release the charge connector lock.
e. Press the charge connector release button and pull the charge connector to remove it. HOLD
NISSAN
AAYIA0153ZZ
AAYIA0091ZZ
AAYIA0145ZZ
AAYIA0353ZZ
FRG–20
Powering Down the High-voltage System
The
high-voltage system can be shut down with any 1 of the following procedures:• Turn OFF the power switch anddisconnect the 12-volt battery.
Refer to Primary Procedure (FRG–22) .
•
Remove the fuses for the high-voltage control system and disconnect the 12-volt battery.
Refer to Alternate Procedure 1 (Remove Fuses) (FRG–23).
•
Remove the service plug and disconnect the 12-volt battery.
Refer to Alternate Procedure 2 (Remove Service Plug) (FRG–26).
Primary
Procedure
1. Check the READY indicator status. If it is ON, the high-voltage system is active.
2.
Place the selector lever in the Park (P) position.
3. Press the power switch once to turn OFF the high- voltage system. Then verify whether the READY indicator is OFF and continue to the next steps to
open
the hood for 12-volt battery negative cable access.
If the READY indicator does not turn off, refer
to Alternate Procedure 1 (Remove Fuses) (FRG–23)
4. If possible, keep the Nissan Intelligent Key® at least 5
meters (16 feet) away from the vehicle.
5. Open the hood. AAYIA0091ZZ
HOLD
AAYIA0144ZZ
AAYIA0145ZZ
FRG–22