2017 INFINITI Q50 HYBRID lock

[x] Cancel search: lock

Page 20 of 43

INFINITI Q50 HYBRID 2017  First responder´s Guide 3-3.1 High-voltage System Shut-Down Procedure
Any
of the following procedures can shut down the high-voltage system. The first response operation
should only begin after shutting down the high-voltage

Page 21 of 43

INFINITI Q50 HYBRID 2017  First responder´s Guide Powering Down the High-voltage System
The
high-voltage system can be shut down with any 1 of the following procedures:• Turn OFF the power switch and disconnect the 12-volt battery. Refer to Primary

Page 24 of 43

INFINITI Q50 HYBRID 2017  First responder´s Guide Alternate Procedure 1 (Disconnect Underhood Fuse Panel)
NO
TE:
Before disconnecting the underhood fuse panel and the negative (-) battery cable, if
necessary, lower the windows, adjust the steering co

Page 27 of 43

INFINITI Q50 HYBRID 2017  First responder´s Guide Alternate Procedure 2 (Remove Service Plug)
DANGER
• Do not remove the service plug without always wearing appropriate Personal
Protective Equipment (PPE) to help protect the responder from serious

Page 30 of 43

INFINITI Q50 HYBRID 2017  First responder´s Guide 9. Remove the service plug (A) by pulling the locking lever (B) , then pressing the locking tab (C)
and rotating the handle (D) fully outward. Using the handle, pull the service plug (E) completely
ou

Page 36 of 43

INFINITI Q50 HYBRID 2017  First responder´s Guide 3-3.5 High-voltage Battery Damage And Fluid Leaks
The high-voltage battery contains electrolyte solution. To avoid exposure to electrolyte
solution
and serious personal injury, always wear appropriate

Page 37 of 43

INFINITI Q50 HYBRID 2017  First responder´s Guide 3. Adjust steering wheel and front seat position (if necessary) as shown below:
4.
Remove front seat head restraint (if necessary) .
The front seat head restraint can be removed by
pressing the lock k