INFINITI Q50 HYBRID 2017  Dismantling Guide • The high-voltage system and high-voltage capacitor may remain powered for up to
approximately 10 minutes after the vehicle is shut off. Personal Protective Equipment
(PPE) must always be worn when

Page 16 of 55

INFINITI Q50 HYBRID 2017  Dismantling Guide 3. Preparation for Dismantling
DANGER
• Failure to properly shut down the high-voltage electrical system before the
Dismantling Procedures are performed will result in serious injury or death from
e

Page 17 of 55

INFINITI Q50 HYBRID 2017  Dismantling Guide 3-1 Preparation Items
Preparation Items
SpecificationPurpose
PPE
(personal protective equipment): Up to 1,000V For protection from high-
voltage electrical shock.
Insulated gloves Insulated shoes
–

Page 18 of 55

INFINITI Q50 HYBRID 2017  Dismantling Guide 3-2 Personal Protective Equipment (PPE) and Insulated Tools
3-2.1
Personal Protective Equipment (PPE) Protective Wear Control
Perform an inspection of the Personal Protective Equipment (PPE) items bef

Page 19 of 55

INFINITI Q50 HYBRID 2017  Dismantling Guide NOTE:
The
engine must not be running at this time. If the engine has restarted, repeat the
previous steps.
9. Release the parking brake.
10. Unbuckle the seat belt and open the driver door. The READY

Page 20 of 55

INFINITI Q50 HYBRID 2017  Dismantling Guide 3-4 How to Handle a Damaged Vehicle
3-4.1
High-voltage System Shut-Down Procedure
Any of the following procedures can shut down the high-voltage system. The dismantling operation canonly
begin after s

Page 21 of 55

INFINITI Q50 HYBRID 2017  Dismantling Guide Powering Down the High-voltage System
The
high-voltage system can be shut down with any 1 of the following procedures:• Turn OFF the power switch and disconnect the 12-volt battery. Refer to Primary

Page 23 of 55

INFINITI Q50 HYBRID 2017  Dismantling Guide NOTE:
If
the electrical release does not work, the trunk will have to be forced open.
6. Open the 12-volt battery service access cover.
7. Disconnect negative (-) battery cable and cover it withinsula