
Chevrolet VOLT Owner Manual (GMNA-Localizing-U.S./Canada/Mexico-
9807421) - 2017 - CRC - 11/18/15
Instruments and Controls 117
Lamps On Reminder
This light comes on when the
exterior lamps are in use. See
Exterior Lamp Controls0149.
Cruise Control Light
The cruise control light is white
when the cruise control is on and
ready, and turns green when the
cruise control is set and active.
See Cruise Control 0194.
Adaptive Cruise Control Light
This light comes on when the
Adaptive Cruise Control (if
equipped) is active. See Adaptive
Cruise Control 0196.
Door Ajar Light
This light comes on when a door is
open or not securely latched.
Information Displays
Power Flows
To view the Power Flow screens,
touch Energy on the infotainment
display and then touch Power Flow
at the bottom of the touch screen.
The Power Flow screens indicate
the current system operating
condition. The screens show the
energy flow between the engine,
electric drive unit, and high voltage
battery. These components will be
highlighted when they are active.
Battery Power - Battery is active
with energy flowing to the wheels.

Chevrolet VOLT Owner Manual (GMNA-Localizing-U.S./Canada/Mexico-
9807421) - 2017 - CRC - 11/18/15
118 Instruments and Controls
Battery Power - Vehicle is stationary
in electric mode and no power is
flowing to the wheels.
Engine Power - Engine is active
with energy flowing to the wheels.
Engine Power - Vehicle is stationary
in Extended Range Mode and no
power is flowing to the wheels.
Engine Power - Engine is active
with energy flowing to the wheels.
Engine is charging the battery.
Engine Power - Vehicle is stationary
and no power is flowing to the
wheels. Engine is charging the
battery.
Engine and Battery Power - Both
the engine and battery are active
with energy flowing to the wheels.

Chevrolet VOLT Owner Manual (GMNA-Localizing-U.S./Canada/Mexico-
9807421) - 2017 - CRC - 11/18/15
Instruments and Controls 119
Engine and Regen Power Recovery
- Engine is active. Power from the
wheels returns to the battery during
regenerative braking or coasting.
Regen Power Recovery - Power
from the wheels returns to the
battery during regenerative braking
or coasting.
Power Off - No power is flowing to
the wheels.
Programmable Charging
Important Information About
Portable Electric Vehicle Charging
.Charging an electric vehicle can
stress a building’ s electrical
system more than a typical
household appliance.
. Before you plug into any
electrical outlet, have a qualified
electrician inspect and verify the
electrical system (electrical
outlet, wiring, junctions, and
protection devices) for
heavy-duty service at a 12 amp
continuous load. .
Electrical outlets may wear out
with normal usage or be
damaged over time, making
them unsuitable for electric
vehicle charging.
. Check the electrical outlet/plug
while charging and discontinue
use if the electrical outlet/plug is
hot, then have the electrical
outlet serviced by a qualified
electrician.
. When outdoors, plug into an
electrical outlet that is
weatherproof while in use.
. Mount the charging cord to
reduce strain on the electrical
outlet/plug.
{Danger
Improper use of portable electric
vehicle charge cords may cause
a fire, electrical shock, or burns,
and may result in damage to
property, serious injury, or death.
(Continued)

Chevrolet VOLT Owner Manual (GMNA-Localizing-U.S./Canada/Mexico-
9807421) - 2017 - CRC - 11/18/15
120 Instruments and Controls
Danger (Continued)
.Do not use extension cords,
multi-outlet power strips,
splitters, grounding
adaptors, surge protectors,
or similar devices.
. Do not use an electrical
outlet that is worn or
damaged, or will not hold
the plug firmly in place.
. Do not use an electrical
outlet that is not properly
grounded.
. Do not use an electrical
outlet that is on a circuit with
other electrical loads.
Programmable Charge Modes
This vehicle has three
programmable charge modes. To
view the current charge mode status
in the center stack display, touch
Energy in the infotainment display
and then touch Charging at the
bottom of the touch screen. The Charge Start and Charge
Complete time estimates are also
displayed on the screen. These
estimates are most accurate when
the vehicle is plugged in and in
moderate temperature conditions.
Charge Mode Status
Immediately :
The vehicle starts
charging as soon as it is connected
to an electrical outlet. See Plug-In
Charging 0215.
Delayed Based on Departure
Time : The vehicle estimates the
charging start time considering the
programmed departure time for the
current day of the week. Charging
begins at the start time and is
complete by the departure time only
if sufficient time is allowed after the
charge cord is plugged in.

Chevrolet VOLT Owner Manual (GMNA-Localizing-U.S./Canada/Mexico-
9807421) - 2017 - CRC - 11/18/15
Instruments and Controls 121
Delayed (Electric Rate and
Departure Time) :The vehicle
estimates the charging start time
based on the utility rate schedule,
utility rate preference, and the
programmed departure time for the
current day of the week. The vehicle
will charge during the least
expensive rate periods to achieve a
full battery charge by the departure
time. Electrical rate information from
the utility company for the charging
location is required for this mode.
Also, if the selected electric rate
settings result in a very long charge
completion time, the vehicle will
start charging immediately upon
plug-in. For example, if the electric
rate table is set up with all “Peak”
rates and the rate preference is to
charge during “Off-Peak”rates only,
then the vehicle will start charging
immediately upon plug-in.
Charge Limit Preference Selection
The Charge Limit Preference setting
allows the customer to select their
vehicle’s charge level so it matches
the capability of their charging
location. If the vehicle consistently stops charging after plugging in, or if
a circuit breaker continues to trip,
reducing to a lower Charge Limit
Preference may resolve the issue.
The Charge Limit Preference should
be configured to match the electrical
current rating for the electrical outlet
that the charge cord is connected
to. The Charge Limit Preference
settings are:
.
Maximum: Limits AC current to
12 amps
. Reduced: Limits AC current to
8 amps
Exact current levels may vary from
the values shown in this manual.
Check the vehicle for the current
available levels. The Charge Limit Preference setting
resets to the Reduced 8 amp setting
each time the vehicle is driven.
Location Based Charging can be
enabled to maintain Maximum
12 amp setting at a specified Home
location. See
“Location Based
Charging” later in this section.
The Charge Limit Preference setting
can be changed at any time while
the center stack display is operable.
{Warning
Using a charge level that exceeds
the electrical circuit or electrical
outlet capacity may start a fire or
damage the electrical circuit. Use
the lowest charge level until a
qualified electrician inspects the
electrical circuit capacity. Use the
lowest charge level if the
electrical circuit or electrical outlet
capacity is not known.

Chevrolet VOLT Owner Manual (GMNA-Localizing-U.S./Canada/Mexico-
9807421) - 2017 - CRC - 11/18/15
122 Instruments and Controls
Charge Mode Selection
From the main charging screen,
touch Charge Mode.
Select one option:
.Immediately Upon Plug In
. Delayed Based on
Departure Time
. Delayed (Electric Rate and
Departure Time)
Departure Time Entry
From the main charging screen,
touch Next Planned Departure.
1. Touch the day to change.
2. Touch
yorzto change the
hours and minutes.
3. Touch
yorzto change AM
or PM.
4. Touch
Sto store changes and
return to the previous screen.
Charge Rate Information
From the Delayed Charge Mode
Status screen, touch Charge Rate
Information.
Select one of the following:
. Charge Completion: Earliest
Possible/Latest Possible.
. Electric Rate Schedule.
. Charge Rate Preference.
Earliest or Latest Completion Time
If the vehicle calculates that the cost
would be the same for various
charge modes based on the charge
rates selected, select to finish the
charge at the earliest possible time
or the latest possible time. Use the
Earliest setting to charge as soon as
possible if there is a planned
departure prior to the scheduled
departure time. Use the Latest
setting to optimize energy usage.

Chevrolet VOLT Owner Manual (GMNA-Localizing-U.S./Canada/Mexico-
9807421) - 2017 - CRC - 11/18/15
Instruments and Controls 123
Charge Rate Preference Selection
From the main charging screen,
touch Charge Rate Information and
then touch Charge Rate Preference.
Touch one of the following options
to select the Charge Rate
Preference:
.Charge during Peak, Mid-Peak,
and Off-Peak Rates: The vehicle
can charge during any rate
period to satisfy the next
planned departure time.
However, it will select when to
charge to minimize the total cost
of the charge.
. Charge during Mid-Peak and
Off-Peak Rates: The vehicle will
charge during Off-Peak and/or
Mid-Peak rate periods only and will select when to charge to
minimize the total cost of the
charge.
. Charge during Off-Peak Rates:
The vehicle will only charge
during Off-Peak rate periods.
Charging begins at the start time
and is complete by the departure
time only if sufficient time is allowed
after the charge cord is plugged in.
For example, if the vehicle is
plugged in for only one hour prior to
the departure time, and the battery
is completely discharged, the
vehicle will not be fully charged by
the departure time regardless of the
rate selection.
Also, if the selected electric rate
settings result in a very long charge
completion time, the vehicle will
start charging immediately upon
plug-in. For example, if the electric
rate table is set up with all Peak
rates and the rate preference is to
charge during Off-Peak rates only,
then the vehicle will start charging
immediately upon plug-in. Electric Rate Plan Selection
Electric rates, or cost per unit, may
vary based on time, weekday/
weekend, and season. During the
day when the demand for electricity
is high, the rates are usually higher
and are called Peak rates. At night
when the demand for electricity is
low, the rates are usually lower and
are called Off-Peak rates. In some
areas, a Mid-Peak rate is offered.
Contact the utility company to obtain
the rate schedule for your area. The
summer and winter start dates must
be established to use a summer/
winter schedule.
From the Charge Rate Information
screen, touch Electric Rate
Schedule.

Chevrolet VOLT Owner Manual (GMNA-Localizing-U.S./Canada/Mexico-
9807421) - 2017 - CRC - 11/18/15
124 Instruments and Controls
To edit the Summer/Winter
Schedule:1. Select Summer/Winter for the Rate Schedule Type.
2. Touch Edit Electric Rate Schedule.
To edit the Yearly Schedule: 1. Select Yearly for the Rate Schedule Type.
2. Touch Edit Electric Rate Schedule.
Summer/Winter Schedule Start
Date Entering
To toggle between a yearly
schedule or a summer/winter
schedule, touch Rate
Schedule Type.
To edit the Rate Schedule Season
Start Dates: 1. Touch Edit Electric Rate Schedule on the Electric Rate
Schedule Screen.
2. Touch the summer icon.
3. Touch
yorzto set the
month and day for the start of
summer.
4. Touch the winter icon.
5. Touch
yorzto set the
month and day for the start of
winter.
6. Touch
Sto save changes.
Electric Rate Schedule Editing
From the Charge Rate Information
Screen touch Electric Rate
Schedule. Select the season you
wish to edit if summer/winter rates
are selected. If yearly rate schedule
is selected no summer/winter icon
will appear. 1. Touch Weekday or Weekend
Rates
2. Touch the rate time window tobe changed.
.Weekdays are Monday
through Friday and use the
same rate schedule.
. Weekends are Saturday
and Sunday and use the
same rate schedule.
Both weekday and weekend
schedules must be set. The rate
schedule only applies for a 24-hour
period, starting at 12:00 AM and
ending at 12:00 AM. There can be
five rate changes for each day; not
all must be used.