INFINITI QX60 HYBRID 2016  First Responder´s 2-5 High-Voltage Safety System
The
high-voltage safety system is intended to help keep vehicle occupants and emergency responders safe
from high-voltage electricity. • A high-voltage fuse provides s

Page 15 of 42

INFINITI QX60 HYBRID 2016  First Responder´s 2-6 High-Voltage Circuit Shut-Off System
This
vehicle is equipped with a system to shut off the current from the high-voltage battery by the following
methods: Service plug
Positioned in the right rea

Page 17 of 42

INFINITI QX60 HYBRID 2016  First Responder´s 3-1 Preparation Items
Preparation Items
Specification Purpose
PPE
(personal protective
equipment): Up to 1,000V
For protection from high-voltage
electrical shock.
Insulated gloves Insulated shoes
–

Page 19 of 42

INFINITI QX60 HYBRID 2016  First Responder´s 3-3 How to Handle a Damaged Vehicle at an Accident Scene
NO
TE:
If any air bags have deployed in the following 3 situations, the high-voltage (HV) system has
been designed to automatically shut off at

Page 20 of 42

INFINITI QX60 HYBRID 2016  First Responder´s 3-3.1 High-Voltage System Shut-Down Procedure
Any
of the following procedures can shut down the high-voltage system. The first response operation
should only begin after shutting down the high-voltage

Page 21 of 42

INFINITI QX60 HYBRID 2016  First Responder´s Powering Down the High-Voltage System
The
high-voltage system can be shut down with any 1 of the following procedures:• Turn OFF the ignition switch and disconnect the 12-volt battery. Refer to Prim

Page 22 of 42

INFINITI QX60 HYBRID 2016  First Responder´s 5. Pull release handle (1) and pull up release lever (2) to open hood.
6.
Remove traction motor inverter cover (1) .
7. Disconnect negative (-) battery cable and cover it with insulated tape.
8. Wait

Page 24 of 42

INFINITI QX60 HYBRID 2016  First Responder´s 5. Remove traction motor inverter cover (1) .
6.
Disconnect negative (-) battery cable and cover it with
insulated tape.
7. Wait approximately ten (10) minutes for complete
discharge of the high-volta