2016 INFINITI Q50 HYBRID battery

[x] Cancel search: battery

Page 15 of 54

INFINITI Q50 HYBRID 2016  Dismantling Guide 2-6 High-voltage Circuit Shut-Off System
This
vehicle is equipped with a system to shut off the current from the high-voltage battery by the following
methods: Service plug
Positioned in the center ar

Page 16 of 54

INFINITI Q50 HYBRID 2016  Dismantling Guide 3. Preparation for Dismantling
DANGER
• Failure to properly shut down the high-voltage electrical system before the
Dismantling Procedures are performed will result in serious injury or death from
e

Page 17 of 54

INFINITI Q50 HYBRID 2016  Dismantling Guide 3-1 Preparation Items
Preparation Items
SpecificationPurpose
PPE
(personal protective equipment): Up to 1,000V For protection from high-
voltage electrical shock.
Insulated gloves Insulated shoes
–

Page 18 of 54

INFINITI Q50 HYBRID 2016  Dismantling Guide 3-2 Personal Protective Equipment (PPE) and Insulated Tools
3-2.1
Personal Protective Equipment (PPE) Protective Wear Control
Perform an inspection of the Personal Protective Equipment (PPE) items bef

Page 19 of 54

INFINITI Q50 HYBRID 2016  Dismantling Guide NOTE:
The
engine must not be running at this time. If the engine has restarted, repeat the previous
steps.
9. Release the parking brake.
10. Unbuckle the seat belt and open the driver door. The READY

Page 20 of 54

INFINITI Q50 HYBRID 2016  Dismantling Guide • The vehicle contains parts that contain powerful magnets. If a person who is wearing
a
pacemaker or other medical device is close to these parts, the medical device may be
affected by the magnets.

Page 21 of 54

INFINITI Q50 HYBRID 2016  Dismantling Guide Primary Procedure
NO
TE:
Before disconnecting the 12-volt battery terminal, if necessary, lower the windows, adjust
the steering column, adjust the seats, unlock the doors, etc. Once 12-volt battery i

Page 23 of 54

INFINITI Q50 HYBRID 2016  Dismantling Guide NOTE:
If
the electrical release does not work, the trunk will have to be forced open.
6. Open the 12-volt battery service access cover.
7. Disconnect negative (-) battery cable and cover it withinsula