10-1
10
EBU25962
SPECIFICATIONS
Dimensions:Overall length:2065 mm (81.3 in)
Overall width: 1180 mm (46.5 in)
Overall height:
1240 mm (48.8 in)
Seat height: 905 mm (35.6 in)
Wheelbase: 1250 mm (49.2 in)
Ground clearance:
275 mm (10.8 in)
Minimum turning radius: 3200 mm (126 in)Weight:Curb weight:
294.0 kg (648 lb)Noise and vibration level:Noise level (77/311/EEC):YFM550DF 79.0 dB(A)@2950 r/min (EUR)(FRA)(GBR)
YFM550PF 79.0 dB(A)@2950 r/min (EUR)(FRA)(GBR)
YFM550PHF 79.0 dB(A)@2950 r/min
Vibration on seat (EN1032, ISO5008): YFM550DF Will not exceed 0.5 m/s² (EUR)(FRA)(GBR)
YFM550PF Will not exceed 0.5 m/s² (EUR)(FRA)(GBR)
YFM550PHF Will not exceed 0.5 m/s² Vibration on handle (EN1032, ISO5008):
YFM550DF Will not exceed 2.5 m/s² (EUR)(FRA)(GBR)
YFM550PF Will not exceed 2.5 m/s² (EUR)(FRA)(GBR)
YFM550PHF Will not exceed 2.5 m/s²
Engine:Engine type:Liquid cooled 4-stroke, SOHC
Cylinder arrangement: Single cylinder
Displacement: 558 cm³
Bore × stroke:
92.0 × 84.0 mm (3.62 × 3.31 in)
Compression ratio: 9.3 : 1
Starting system: Electric starter
Lubrication system:
Wet sumpEngine oil:Recommended brand:YAMALUBE
U2LB61E0.book Page 1 Friday, February 21, 2014 3:03 PM
10-5
10
Coolant temperature warning light:LED
EPS warning light: YFM550PF LED
YFM550PHF LED
Park indicator light: LED
On-Command four-wheel-drive/differential gear lock
indicator: LCD
Engine trouble warning light:
LED
High-range indicator light: LED
Low-range indicator light: LED
Differential gear lock indicator light:
LEDFuses:Main fuse:40.0 A
Fuel injection system fuse:
15.0 A
EPS fuse: YFM550PF 40.0 A
YFM550PHF 40.0 A
Headlight fuse: 10.0 A
Signaling system fuse: 5.0 A
Ignition fuse:
10.0 A Auxiliary DC jack fuse:
10.0 A
Four-wheel-drive motor fuse: 10.0 A
Radiator fan motor fuse:
20.0 A
EBU30402For Europe only
The figures quoted are emission levels and are not
necessarily safe working levels. Whilst there is a
correlation between the emission and exposure
levels, this cannot be used reliably to determine
whether or not further precautions are required.
Factors that influence the actual level of exposure
of work-force include the characteristics of the
work room, the other sources of noise, etc. i.e. the
number of machines and other adjacent process-
es, and the length of time for which an operator is
exposed to the noise. Also the permissible expo-
sure level can vary from country. This information,
however, will enable the user of the machine to
make a better evaluation of the hazard and risk.
U2LB61E0.book Page 5 Friday, February 21, 2014 3:03 PM