2015 INFINITI Q50 HYBRID ignition

[x] Cancel search: ignition

Page 15 of 43

INFINITI Q50 HYBRID 2015  First responder´s Guide 2-6 High Voltage Circuit Shut-Off System 
This vehicle is equipped with a system to shut off the current from the high voltage battery by the following methods:
Service plug Positioned in the center a

Page 21 of 43

INFINITI Q50 HYBRID 2015  First responder´s Guide Powering Down the High Voltage System 
The high voltage system can be shut down with any 1 of the following procedures:• Turn OFF the power switch and disconnect the 12-volt battery. Refer to
Primar

Page 27 of 43

INFINITI Q50 HYBRID 2015  First responder´s Guide Alternate Procedure 2 (Remove Service Plug)
DANGER
•Do not remove the service plug without always wearing appropriate Personal
Protective Equipment (PPE) to help protect the responder from serious i

Page 30 of 43

INFINITI Q50 HYBRID 2015  First responder´s Guide 9. Remove the service plug (A) by pulling the locking lever (B) , then pressing the locking tab (C)and rotating the handle (D) fully outward. Using the handle, pull the service plug (E) completely 
ou

Page 31 of 43

INFINITI Q50 HYBRID 2015  First responder´s Guide 3-3.3 Vehicle Fire
• Always utilize full Personal Protective Equipment (PPE) and self-contained breathingapparatus during fire fighting operations. Smoke from a Q50 HYBRID vehicle fire is 
similar t