82D-23V1 MR-376-X76-82D000$090.mif
82D
UCH
Vdiag No.: 0F
NOTESOnly check conformity after a complete check with the diagnostic tool.
The values indicated in this conformity check are given as examples.
Application conditions: engine stopped, ignition on.
FunctionParameter or Status
Check or ActionDisplay and notes Fault finding
ImmobiliserET127:Immobiliser
warning lightOFFIn the event of a fault, apply
the interpretation of status
ET127 (see 87B, UCH).
ET184:Valid key codeYES when the ignition is
switched onIn the event of a fault, apply
the interpretation of status
ET184.
ET185:Key code
receivedYES when the ignition is
switched onIn the event of a fault, apply
the interpretation of status
ET185.
ET549:Immobiliser activeNOIn the event of a fault, apply
the interpretation of status
ET549.
KeyPR056:Number of keys
allocated2 keys on leaving the
factory and programming of
up to 4 keys in After-SalesIn the event of a fault, apply
the interpretation of parameter
PR056.
ET183:Key already
programmed for
the vehicleYESIn the event of a fault, apply
the scenario SC015 Key
allocation
DoorsET489:Front doorsOpen when opening a front
door.In the event of a fault, apply
the interpretation of status
ET489 (see 87B, UCH).
ET551:Rear doors or
bootOpen when opening a rear
door or the luggage
compartment lid.In the event of a fault, apply
the interpretation of status
ET551 (see 87B, UCH).
UCH_V0F_CCONF
ACCESS - SECURITY
Fault finding – Conformity check
82D-32
AFTER REPAIRCarry out another fault finding check on the system.
Deal with any other faults.
Clear the stored faults.
V1 MR-376-X76-82D000$150.mif
ACCESS - SECURITY
Fault finding – Interpretation of commands82D
UCH
Vdiag No.: 0F
AC004
AC005
AC006
CONTINUED
Passenger door electric lock:
–20C between components 141 and 645,
–20D between components 141 and 645,
Boot lid electric lock:
–20C between components 142 and 645,
–20D between components 142 and 645,
Side door central locking (depending on version):
–20C between components 1200 and 645,
–20D between components 1200 and 645,
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the techline.