721-2. Hybrid system
GS450h_U (OM30D01U)
■Regenerative braking
In the following situations, kinetic energy is converted to electric energy and decel-
eration force can be obtained in conjunction with the recharging of the hybrid bat-
tery (traction battery).
●The accelerator pedal is released while driving with the shift position in D or S.
●The brake pedal is depressed while driving with the shift position in D or S.
■EV indicator
■Conditions in which the gasoline engine may not stop
The gasoline engine starts and stops auto matically. However, it may not stop auto-
matically in the following conditions:
●During gasoline engine warm-up
●During hybrid battery (t raction battery) charging
●When the temperature of the hybrid battery (traction battery) is high or low
●When the heater is switched on
■Charging the hybrid battery (traction battery)
●As the gasoline engine charges the hybrid battery (traction battery), the battery
does not need to be charged from an outside source. However, if the vehicle is left
parked for a long time the hybrid battery will slowly discharge. For this reason, be
sure to drive the vehicle at least once every few months for at least 30 minutes or
10 miles (16 km). If the hybrid battery becomes fully discharged and you are unable
to jump-start the vehicle with the 12-v olt battery, contact your Lexus dealer.
●If the shift lever is in N, the hybrid ba ttery (traction battery) will not be charged.
Always put the shift lever in P when the vehicle is stopped. When driving in heavy
traffic, operate the vehicle with the shift le ver in D or S to avoid discharging the bat-
tery.
■Charging the 12-volt battery
P. 771
The EV indicator comes on when driving the
vehicle using only the electric motor (traction
motor).
Page 478 of 860
478
GS450h_U (OM30D01U)
5-3. Using the audio system
Select the folder/album name on
the screen.
Select the desired tab and select
the desired folder, artist or album.
Character screen buttons, “ABC”,
“DEF” etc., allow a direct jump to list
entries that begin with the same letter
as the character button.
Each time the same character screen
button is selected, the list starting with
the subsequent character is displayed.
, : Select to move the list up or
down by 5 folder/artist/album groups.
“TUNE/SCROLL” knob: Turn the
knob clockwise or counterclockwise
to quickly scroll up or down the folder/
artist/album list.
, : If appears to the right of an
item name, the complete name is too
long for the screen. Select to scroll
to the end of the name. Select to
move to the beginning of the name.
Selecting a folder , artist or album
1
2
Page 770 of 860
770
GS450h_U (OM30D01U)
7-2. Steps to take in an emergency
If the 12-volt battery is discharged
If you have a set of jumper (or booster) cables and a second vehicle with a
12-volt battery, you can jump start your vehicle by following the steps
below.
Open the trunk lid and remove
the 12-volt battery cover.
In the event that the trunk opener can-
not be used, use the mechanical key to
open the trunk. ( P. 76 7 )
Connect the jumper cables according to the following procedure:
Positive (+) battery terminal on your vehicle
Positive (+) battery terminal on the second vehicle
Negative (-) battery terminal on the second vehicle
Negative (-) battery terminal on your vehicle
The following procedures may be used to start the hybrid system if the
12-volt battery is discharged.
You can also call your Lexus dealer or a qualified repair shop.
1
2
1
2
3
4
Page 771 of 860

7717-2. Steps to take in an emergency
GS450h_U (OM30D01U)
7
When trouble arises
Start the engine of the second vehicle. Increase the engine speed
slightly and maintain at that le vel for approximately 5 minutes to
recharge the 12-volt battery of your vehicle.
Open and close any of th e doors of your vehicle with the power switch
off.
Maintain the engine speed of the se cond vehicle and start the hybrid
system of your vehicle by turning the power switch to ON mode.
Make sure the “READY” indicator co mes on. If the indicator does not
come on, contact your Lexus dealer.
Once the hybrid system has started, remove the jumper cables in the
exact reverse order from wh ich they were connected.
Once the hybrid system starts, have the vehicle inspected at your Lexus
dealer as soon as possible.
■Starting the hybrid system when the 12-volt battery is discharged
The hybrid system cannot be started by push-starting.
■To prevent 12-volt battery discharge
●Turn off the headlights and the audio system while the hybrid system is off.
●Turn off any unnecessary electrical compon ents when the vehicle is running at a
low speed for an extended period, such as in heavy traffic.
■Charging the 12-volt battery
The electricity stored in the 12-volt battery will discharge gradually even when the
vehicle is not in use, due to natural discharge and the draining effects of certain elec-
trical appliances. If the vehicle is left for a long time, the 12-volt battery may dis-
charge, and the hybrid system may be unable to start. (The 12-volt battery recharges
automatically while the hybrid system is operating.)
3
4
5
6
7
Page 772 of 860

7727-2. Steps to take in an emergency
GS450h_U (OM30D01U)
■When recharging or replacing the 12-volt battery
●Make sure the key is not inside the vehicle when recharging or replacing the 12-volt
battery to prevent the doors from being locked with the key left inside the vehicle
when the alarm operates.
●In some cases, it may not be possible to unlock the doors using the smart access
system with push-button start when the 12-volt battery is discharged. Use the wire-
less remote control or the mechanical key to lock or unlock the doors.
●The hybrid system may not start on the fir st attempt after the 12-volt battery has
recharged but will start normally after the second attempt. This is not a malfunction.
●The power switch mode is memorized by the vehicle. When the 12-volt battery is
reconnected, the system will return to the mode it was in before the 12-volt battery
was discharged. Before disconnecting the 12 -volt battery, turn the power switch off.
If you are unsure what mode the power switch was in before the 12-volt battery dis-
charged, be especially careful when reconnecting the 12-volt battery.
CAUTION
■Avoiding 12-volt battery fires or explosions
Observe the following precautions to prev ent accidentally igniting the flammable
gas that may be emitted from the 12-volt battery:
●Make sure each jumper cable is connected to the correct terminal and that it is
not unintentionally in contact with any other than the intended terminal.
●Do not allow the other end of the jumper cable connected to the “+” terminal to
come into contact with any other parts or metal surfaces in the area, such as
brackets or unpainted metal.
●Do not allow the + and - clamps of the jumper cables to come into contact with
each other.
●Do not smoke, use matches, cigarette lighters or allow open flame near the 12-
volt battery.