4. Apply foot brake and press the ignition switch to turn the system ON. Confirm READY
indicator in instrument cluster turns ON.
a. If the engine starts, leave the engine on until idling stops.
b. If the engine does NOT start, move on to next step.
5. Remove the shift lock cover (A) using a suitable tool.
6. Push down the shift lock (B) as shown in the illustration.
7. Push the shift selector button (C) and move the shift selector to Neutral (N) position (D) while holding down
the shift lock.
NOTE:
DO NOT press accelerator or foot brake after
moving the shift selector to the Neutral (N)
position. Otherwise Li-ion battery will start to be
charged.
8. Release the parking brake.
9. Turn ON electric devices such as headlamps, A/C (set to the coldest temperature) and rear window defogger to discharge the high voltage battery. Allow approximately 15 minutes to
discharge. Discharge is complete when the READY indicator (B) (green) turns OFF and
the
hybrid system warning indicator (C) (orange) turns ON.
10. Press the ignition switch (A) to turn the system OFF.
Please contact following number if the vehicle could not be discharged. • 1-800-662-6200 (US) or 1-800-361-4792 (Canada)
• Hours of operation are 8am-5pm (Monday-Friday) Eastern, Central and Pacific time zones. AAYIA0067ZZ
AAYIA0033ZZ
19
4. Jump Starting
T
o start the hybrid system with a booster battery, the instructions and precautions below must be followed. If done incorrectly, jump starting can lead to a 12V battery explosion, resulting in severe
personal
injury or death. It could also damage your vehicle.
Jump starting provides power to the 12V system to allow the electrical systems to operate. The electrical
systems must be operating to allow the Li-ion battery to be charged. Jump starting does not charge the
Li-ion battery.
Discharged 12V battery may cause the following issues: • The instrument cluster cannot be displayed while the ignition switch is turned ON. (The hybridsystem cannot start.)
• Headlamps, horn, etc. are weak. • To avoid electrical shock, the high voltage Li-ion battery CANNOT be jump started.
•
Explosive hydrogen gas is always present in the vicinity of the 12V battery. Keep all
sparks and flames away from the 12V battery.
• Do not allow battery fluid to come into contact with eyes, skin, clothing or painted surfaces. Battery fluid is a corrosive sulfuric acid solution that can cause severe burns. If
the fluid comes into contact with anything, immediately flush the contacted area with
water.
• The booster battery must be rated at 12 volts. Use of an improperly rated battery can damage the vehicle.
• Whenever working on or near a 12V battery, always wear suitable eye protectors (for example, goggles or industrial safety spectacles) and remove rings, metal bands, or any
other jewelry. Do not lean over the 12V battery when jump starting.
• Do not attempt to jump start a frozen battery. It could explode and cause serious injury.
• M35h HYBRID is equipped with an automatic cooling fan. It could come on at any time. Keep hands and other objects away from it.
• Always follow the jump starting instructions below. Failure to do so could result in damage to the DC/DC converter and cause personal injury.
35