2013 INFINITI M HYBRID engine

[x] Cancel search: engine

Page 3 of 52

INFINITI M HYBRID 2013  Dismantling Guide Table of Contents
FOREWORD
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
INFINITI EMERGENCY CONTACT IN

Page 5 of 52

INFINITI M HYBRID 2013  Dismantling Guide 1. About the INFINITI M35h HYBRID
This
hybrid electric vehicle (HEV) uses two types of batteries. One is a 12V battery that is the same as the
battery in vehicles powered by internal combustion engine

Page 6 of 52

INFINITI M HYBRID 2013  Dismantling Guide 1-1 M35h HYBRID IDENTIFICATION
1-1.1
Exterior and Engine Compartment AAYIA0003ZZ
6

Page 13 of 52

INFINITI M HYBRID 2013  Dismantling Guide No. Component
LocationDescription
a Lithium-ion
(Li-ion)
Battery Trunk area (behind
rear seat back) The Li-ion battery stores and outputs DC
power (Maximum voltage 400V) needed to
propel the vehicle.

Page 18 of 52

INFINITI M HYBRID 2013  Dismantling Guide 3-1 Preparation Items
Preparation Items
Specification Purpose
PPE (personal protective
equipment):
Insulated gloves Up to 1,000V
For
 protection from high voltage electri-
cal shock
Insulated shoes

Page 19 of 52

INFINITI M HYBRID 2013  Dismantling Guide 4. Apply foot brake and press the ignition switch to turn the system ON. Confirm READY
indicator in instrument cluster turns ON.
a. If the engine starts, leave the engine on until idling stops.
b. If

Page 36 of 52

INFINITI M HYBRID 2013  Dismantling Guide 4-1 Jump Starting Procedures
NO
TE:
Jumper cable connections under the hood of the M35h HYBRID are not connected directly
to a battery. They are connected to chassis ground and a fuse box terminal. Re

Page 49 of 52

INFINITI M HYBRID 2013  Dismantling Guide 28. Follow the procedure below to remove the high voltage battery pack from the trunk room.
Touching high voltage components without wearing appropriate PPE will cause
electrocution.
a.
Attach carabin