2012 SSANGYONG KORANDO heater

[x] Cancel search: heater

Page 315 of 1082

SSANGYONG KORANDO 2012  Service Manual 15-390000-00
d. Control conditions
Operation Operating condition PTC Heater
HI
(PTC2)- Coolant temperature < 15℃
PTC  HI ON 
LO
(PTC1)- Coolant temperature 15℃ ≤ 65℃, intake air 
temperature

Page 350 of 1082

SSANGYONG KORANDO 2012  Service Manual 02-4
2. TIGHTENING TORQUE
Name Size Quantity Tightening torque
Heater core screw bolt - 170 ± 7 Nm
Ladder frame bolt M8 X 1.25 X 20 725 ± 2.5 Nm
TGCC M6 X 1.0 X 25 1010 ± 1.0 Nm
Oil drain plug - 13

Page 427 of 1082

SSANGYONG KORANDO 2012  Service Manual 08-4
Problem Possible Cause Action
Coolant 
level is too low
Coolant 
temperature is 
too high
2. INSPECTION
Leak from the radiator
Leak from the coolant auxiliary tank
Leak from the heater core -
-
-

Page 437 of 1082

SSANGYONG KORANDO 2012  Service Manual 08-14
3. COOLANT FLOW DIAGRAM
Heater 
return Water pump
Thermostat
Bypass

Page 438 of 1082

SSANGYONG KORANDO 2012  Service Manual 08-152112-01
Coolant outlet port
to radiator
to water pump (bypass)
to cabin heater
to coolant reservoir
Coolant temperature 
sensor mountinh boss
from cylinder head
Gasket A:
B:
C:
D:
E:
F:
G:
Coolan

Page 548 of 1082

SSANGYONG KORANDO 2012  Service Manual 02-10
Engine compartment fuse and relay box II (SB7~SB9, Ef1, Ef5, Ef9, Ef11, PTC RELAY, FUEL 
HEATER RELAY, HEAD LAMP RELAY(HI, LO)) ▶

Page 1004 of 1082

SSANGYONG KORANDO 2012  Service Manual 01-36810-00
1. SPECIFICATION
Description Specification
HeaterCore size (㎣)200 x 165.5 x 25
Capacity (kcal/h) 4,800
EvaporatorCore size (㎣)254.8 x 196.75 x 60
Capacity (kcal/h) 4,700
Blower Supply

Page 1005 of 1082

SSANGYONG KORANDO 2012  Service Manual 01-4
2. MAJOR CHANGES
1) Heater & Evaporator Module (Wiring Specification)
The driving circuit for the manual A/C ambient temperature sensor is added, giving the change to the 
heater and evaporator m