2012 RENAULT SCENIC test 3

[x] Cancel search: test 3

Page 504 of 510

RENAULT SCENIC 2012 J95 / 3.G Engine And Peripherals EDC16CP33 Workshop Manual 13B-504V12 MR-372-J84-13B300$180.mif
DIESEL INJECTION
Fault finding – Test13B
TEST10
CONTINUED 1
2. If at least one of these values is X < - 5 mg/stroke 
– Check the valve clearance.
– Check the

Page 505 of 510

RENAULT SCENIC 2012 J95 / 3.G Engine And Peripherals EDC16CP33 Workshop Manual 13B-505V12 MR-372-J84-13B300$180.mif
DIESEL INJECTION
Fault finding – Test13B
Part B (except VDiag 18, 04 and 44): 
TEST10
CONTINUED 2
Run SC031 Cylinder operational fault 
finding.
Is SC031 correct

Page 506 of 510

RENAULT SCENIC 2012 J95 / 3.G Engine And Peripherals EDC16CP33 Workshop Manual 13B-506V12 MR-372-J84-13B300$180.mif
DIESEL INJECTION
Fault finding – Test13B
TEST10
CONTINUED 3
Part C:
Confirmation of flow correction fault finding for each injector (individual correction): 
Cle

Page 507 of 510

RENAULT SCENIC 2012 J95 / 3.G Engine And Peripherals EDC16CP33 Workshop Manual 13B-507V12 MR-372-J84-13B300$180.mif
DIESEL INJECTION
Fault finding – Test13B
TEST11 Temperature upstream of turbine too low
Perform a complete fault finding of the 
injection computer using the dia

Page 508 of 510

RENAULT SCENIC 2012 J95 / 3.G Engine And Peripherals EDC16CP33 Workshop Manual 13B-508V12 MR-372-J84-13B300$180.mif
DIESEL INJECTION
Fault finding – Test13B
TEST12 Diesel fuel conformity check
WARNING
During this operation, it is essential to:
– refrain from smoking or bring

Page 509 of 510

RENAULT SCENIC 2012 J95 / 3.G Engine And Peripherals EDC16CP33 Workshop Manual 13B-509V12 MR-372-J84-13B300$180.mif
DIESEL INJECTION
Fault finding – Test13B
TEST12
CONTINUED 1
Weigh the diesel fuel and note the fuel weight after subtracting the weight of the empty plastic cup

Page 510 of 510

RENAULT SCENIC 2012 J95 / 3.G Engine And Peripherals EDC16CP33 Workshop Manual 13B-510V12 MR-372-J84-13B300$180.mif
DIESEL INJECTION
Fault finding – Test13B
TEST12
CONTINUED 2
Note: 
If the weight measured reaches the limit values, the measurement can be performed with a 2230
Page:   < prev 1-10 ... 441-448 449-456 457-464 465-472 473-480