13B-427V12 MR-372-J84-13B300$150.mif
DIESEL INJECTION
Fault finding – Interpretation of commands13B
SC017PARTICLE FILTER REGENERATION
NOTESOnly run this command after interpretation of the following faults:
– DF308 Clogged particle filter,
– DF311 Failed regenerations limit exceeded,
– df312: speed request.
WARNING:
– It is essential to observe the health and safety guidelines (see MR364 (Mégane II ph2), MR370 (Scénic II ph2),
MR 395 (Laguna II ph2), 402 (Vel Satis ph2), 405 (Espace IV ph2) Mechanical, 19B, Exhaust, Particle
filter: Cleaning) and follow the procedure below.
SAFETY INSTRUCTIONS TO BE FOLLOWED:
The regeneration causes exhaust fumes and high temperatures.
It is strongly recommended that you put the vehicle outside during regeneration.
If it is not possible to carry out regeneration outside, use an extractor fan that can withstand the very high
regeneration temperatures (400°C at the exhaust outlet).
Perform regeneration on a surface free from fire risks (oil, dry leaves, etc.).
Nothing should be left in the vicinity of the exhaust pipe.
Check that there are no leaks or blockages in the exhaust pipe,
Repair if necessary.
WARNING:
Check the engine oil level before running the command to avoid any engine racing. The oil level must be
between the minimum level and the middle level on the oil dipstick.
Before performing a particle filter regeneration, it is essential to deactivate the air conditioning
compressor (risk of engine damage) and all the electrical consumers.
IF NECESSARY:
Regeneration can be stopped by pressing the engine start button twice briefly (less than 3 seconds).
Switch off the ignition and wait for the diagnostic tool message (maximum time 8 minutes) Communication
lost with computer: EDC16 C33, check the tool connection and the computer power supply before
switching the ignition back on.
EDC16CP33_V1C_SC017 / EDC16CP33_V54_SC017 / EDC16CP33_V20_SC017 / EDC16CP33_V58_SC017 / EDC16CP33_V5C_SC017 /
EDC16CP33_V24_SC017 / EDC16CP33_V28_SC017 / EDC16CP33_V62_SC017/ EDC16CP33_V26_SC017 / EDC16CP33_V60_SC017
EDC16CP33
Program No.: C4
Vdiag No.: 1C, 20, 24, 26,
28, 54, 58, 5C, 60, 62
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
13B-487
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
V12 MR-372-J84-13B300$170.mif
DIESEL INJECTION
Fault finding – Fault Finding Chart13B
ALP9 PARTICLE FILTER WARNING LIGHT COMES ON TOO OFTEN
NOTESBefore dealing with this customer complaint, check that there are no faults except
DF312 Speed request, and the conformity (or otherwise) of the "parameters" and
"statuses" using the diagnostic tool. Deal with the other faults first.
If the customer complaint is not eliminated, perform the following checks.
Have the last 10 regeneration
attempts failed?Are all the regeneration failures
linked to engine cut-off?
See group parameter (ET706
Stored engine status no. 1 to
ET715 Stored engine status no.
10)
(e.g. ET706 STOPPED)Output 1 Is the distance of PR412 Distance of
last successful regeneration less
than all the parameters of group 2?
(PR794 to PR803 Stored
regeneration failure no.1 to no.10)
Is at least one status for group
1 = STATUS4?Check the exhaust pipe for leaks
or blockage. Repair if necessary.
Carry out an After-Sales
regeneration if not already
performed. To do this, see SC017
Particle filter regeneration in
Interpretation of commands.Output 2
YES
YES
NONO
YES
A
NO
B
EDC16CP33_V18_ALP09 / EDC16CP33_V1C_ALP09 / EDC16CP33_V54_ALP09 / EDC16CP33_V20_ALP09 / EDC16CP33_V58_ALP09 /
EDC16CP33_V5C_ALP09 / EDC16CP33_V24_ALP09 / EDC16CP33_V28_ALP09 / EDC16CP33_V62_ALP09 / EDC16CP33_V26_ALP09 /
EDC16CP33_V60_ALP09
EDC16CP33
Program No.: C4
Vdiag No.: 18, 1C, 20, 24,
26, 28, 54, 58, 5C, 60, 62