13B-79V9 MR-372-J84-13B450$102.mif
13B
DF034
CONTINUED
Check the supply to thermoplunger 4:
– Disconnect the connector of component 1074.
– Connect a test light between connection 3JAC of component 1074 and a chassis earth.
– Run command AC031 Thermoplunger relay no.3.
If the test light illuminates correctly, measure the resistance of the thermoplunger 4 between the following
connection:
–3JAC of component 1074 and a chassis earth,
If the resistance is greater than 2Ω, replace thermoplunger 4.
If the test light does not come on, check the continuity and insulation of the following connection:
– Connection code 3JAC between components 1550 and 1074.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the earthing on the additional heater interface unit:
– Disconnect the connector of component 1550.
– Connect a test light between connections 3JAB and BP27 of component 1550.
– Run command AC031 Thermoplunger relay no.3.
If the test light comes on correctly, replace the additional heater interface unit.
If the test light does not come on, check the continuity and insulation from + 12 V of the following connection:
– Connection code 3JAB between components 120 and 1550.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
DIESEL INJECTION
Fault finding – Interpretation of faults
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 48, 58
13B-80V9 MR-372-J84-13B450$102.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF038
PRESENT
OR
STOREDCOMPUTER
1.DEF: Internal electronic fault
2.DEF: Voltage too low
3.DEF: Data inconsistency
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– starting the engine,
– a road test.
Special notes:
If the fault is present:
– depending on the situation, the level 1 or level 2 warning light is lit for 1.DEF,
–the level 1 warning light comes on for 3.DEF,
–the level 2 warning light comes on for 2.DEF,
– increase in polluting emissions,
– injection cut-off in defect mode,
– the engine stops.
Use bornier Elé. 1681 for all operations on the engine management computer
connectors.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
1.DEF
NOTESNone.
If the fault is stored, clear the fault from the computer memory.
Switch off the ignition, wait for the end of the power latch, then switch the ignition back on. Start the engine and re-
establish dialogue.
If the fault is still present, contact the Techline.
EDC16C36_V44_DF038/EDC16C36_V4C_DF038/EDC16C36_V48_DF038/EDC16C36_V50_DF038/EDC16C36_V54_DF038/
EDC16C36_V58_DF038
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
13B-81V9 MR-372-J84-13B450$102.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF038
CONTINUED
2.DEFNOTESPriorities when dealing with a number of faults:
Deal with faults DF047 Computer supply voltage and
DF046 Battery voltage first, if they are present or stored.
If either of faults DF047 Computer supply voltage or DF046 Battery voltage is present or stored, clear the fault
after dealing with DF046 Battery voltage or DF047 Computer supply voltage.
If the fault is still present, contact the Techline.
3.DEF
NOTESNone.
Contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
13B-82V9 MR-372-J84-13B450$102.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF046
PRESENT
OR
STOREDBATTERY VOLTAGE
1.DEF: Above max threshold
2.DEF: Below minimum threshold
3.DEF: Initialisation not done.
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– starting the engine,
– a road test.
Special notes:
– thermoplungers cut-off,
– engine torque limited,
Computer operating voltage: 6 V < operating voltage < 16.5 V.
It is then not possible to start the engine.
Use bornier Elé.1681 for any operations on the injection computer connectors.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
1.DEF
NOTESNone.
Check the charging circuit, apply Technical Note 6014A Checking the charging circuit.
Carry out the necessary repairs.
EDC16C36_V44_DF046/EDC16C36_V4C_DF046/EDC16C36_V48_DF046/EDC16C36_V50_DF046/EDC16C36_V54_DF046/
EDC16C36_V58_DF046
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
13B-83V9 MR-372-J84-13B450$102.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF046
CONTINUED
2.DEFNOTESUse the Wiring Diagram Technical Notes for the vehicle.
Reminder of computer operating voltage: 6 V < operating voltage < 16.5 V
Using a voltmeter, take a reading of the battery voltage at its terminals.
– Compare the voltage obtained with the value displayed on the diagnostic tool PR074 Battery voltage.
If it there is no difference (less than 1 V):
Recharge and test the battery and replace it if it is defective.
Next check the charge circuit.
If there is a difference (greater than 1 V):
– Check the tightness and the condition of the battery terminals.
– Using the appropriate wiring diagram:
Check the continuity and absence of interference resistance on the following connections:
– Connection code 3FB between components 597 and 120.
– Connection code AP29 between components 597 and 120.
– Connection code NT between components NT and 120.
(Check the four NT connections)
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
3.DEF
NOTESOnly deal with this fault when it is present.
Switch off the ignition and wait for the diagnostic tool message (maximum time 8minutes) Communication lost
with computer: EDC16 C36, check the tool connection and computer power supply before switching the
ignition back on.
Switch on the ignition again and check if the fault is still present.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
13B-84V9 MR-372-J84-13B450$102.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF047
PRESENT
OR
STOREDCOMPUTER SUPPLY VOLTAGE
1.DEF: Voltage outside permitted range of values
NOTESConditions for applying the fault finding procedure to a stored fault:
– The fault is declared after the ignition has been switched on
Special notes:
– impossible to start the engine.
Use bornier Elé.1681 for any operations on the injection computer connectors.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
1.DEF
NOTESImpossible to start.
Check the continuity and absence of interference resistance on the following connection:
– Connection code AP29 between components 597 and 120.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
Check the condition of the injection control unit supply relay (R08) in the engine fuse and relay box (no bad
contacts or oxidation on the relay mounting clips).
If there is a repair procedure (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair) repair the wiring, otherwise replace it.
If the fault does not recur, start the engine and wait 1 min.
Carry out a road test and check the system faults.
If there are no faults, fault finding is complete.
If the fault is still present, contact the Techline.
EDC16C36_V44_DF047/EDC16C36_V4C_DF047/EDC16C36_V48_DF047/EDC16C36_V50_DF047/EDC16C36_V54_DF047/
EDC16C36_V58_DF047
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
13B-85V9 MR-372-J84-13B450$102.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF051
PRESENT
OR
STOREDCRUISE CONTROL/SPEED LIMITER
1.DEF: Cruise control or speed limiter fault.
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– a road test with activation of the cruise control/speed limiter function.
– the engine is started.
Special notes:
If the fault is present, the cruise control/speed limiter is switched off.
Use bornier Elé.1681 for any operations on the injection computer connectors.
1.DEF
NOTESOrder of priority for a combination of faults:
Deal with faults DF196 Pedal sensor circuit gang 1 and
DF198 Pedal sensor circuit gang 2 first if they are stored.
WARNING
This fault may appear if the wiring harness has been damaged.
Follow the procedure described in the Wiring Check in the Introduction.
This check enables the condition and the conformity of the engine wiring harness to be checked.
If fault DF051 is declared present, consult the interpretation of status ET415 Cruise control/speed limiter
deactivation.
Check that by pressing the buttons the statuses change and that, with the ignition switched on, all the values are
correct.
If the fault is still present, contact the Techline.
EDC16C36_V44_DF051/EDC16C36_V4C_DF051/EDC16C36_V48_DF051/EDC16C36_V50_DF051/EDC16C36_V54_DF051/
EDC16C36_V58_DF051
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
13B-86V9 MR-372-J84-13B450$102.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF053
PRESENT
OR
STOREDRAIL PRESSURE REGULATION FUNCTION1.DEF: Above maximum threshold.
2.DEF: Negative loop deviation.
3.DEF: Positive loop deviation.
4.DEF: Below minimum threshold.
NOTESOrder of priority for a combination of faults:
Deal with fault DF643 Rail pressure regulator circuit first if it is present or stored.
Conditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– the engine is started,
– a road test.
Special notes:
If the fault is present:
– engine torque limited for 2.DEF/3.DEF,
–the level 1 warning light comes on for 2DEF/3.DEF.
–the level 2 warning light comes on for 1.DEF/3.DEF/4.DEF,
– engine stops for 1.DEF/3.DEF/4.DEF.
Use bornier Elé.1681 for any operations on the injection computer connectors.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
EDC16C36_V44_DF053/EDC16C36_V4C_DF053/EDC16C36_V48_DF053/EDC16C36_V50_DF053/EDC16C36_V54_DF053/
EDC16C36_V58_DF053
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58