Page 168 of 230

PETROL INJECTION
Fault finding - Status summary table
17B
17B - 168
PETROL INJECTION
Fault finding - Status summary table
17B
17B - 168V9 MR-372-J84-17B050$564.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54PETROL INJECTION
Fault finding - Status summary table
Tool status Diagnostic tool title
ET001+ After ignition computer feed
ET003Engine immobiliser
ET004Air conditioning authorisation
ET006Code programmed
ET021High speed fan assembly request
ET022Low speed fan assembly request
ET023Fast idle speed request
ET042Cruise control/speed limiter
ET047Fuel pump control circuit
ET048Actuator relay control
ET050Canister bleed control
ET051Throttle stop programming
ET052Upstream O
2 sensor heating
ET053Downstream O
2 sensor heating
ET054Idle speed regulation
ET056Richness double loop
ET057Misfiring on cylinder 1
ET058Misfiring on cylinder 2
ET059Misfiring on cylinder 3
ET060Misfiring on cylinder 4
ET061Cylinder 1 recognition
ET062Flywheel signal
ET063Park/Neutral position
ET064Level 1 injection fault
ET065Level 2 Injection fault
ET066LPG fault
ET067LPG ready
ET068LPG tank empty
ET071Transition from petrol mode to LPG mode
ET072Transition from LPG mode to petrol mode
ET073Conditions for switching to LPG mode
ET075Pedal released and throttle closed
MR-372-J84-17B050$564.mif
Page 183 of 230
PETROL INJECTION
Fault finding - Interpretation of statuses
17B
17B - 183
PETROL INJECTION
Fault finding - Interpretation of statuses
17B
17B - 183V9 MR-372-J84-17B050$611.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
ET072
TRANSITION FROM LPG MODE TO PETROL MODE
IN PROGRESS
COMPLETE
NOTESThere must be no present or stored faults.
Ignition on, engine stopped.
Check that the fuel pump starts when petrol mode is entered.
Check status ET025 Fuel pump changes to ACTIVE.
If the fuel pump does not start, check:
– the fuel pump cut-off relay (see DF024 Fuel pump cut-off relay circuit),
– the petrol computer (see17B, Petrol injection).
This fault is detected by the LPG injection computer.
Repair or replace the faulty components, if necessary.
If the status is still not correct, contact the Techline.
AFTER REPAIRRepeat the conformity check from the start.
S3000_V4C_ET072/S3000_V54_ET072
Page 216 of 230

PETROL INJECTION
Fault finding - Interpretation of commands
17B
17B - 216
PETROL INJECTION
Fault finding - Interpretation of commands
17B
17B - 216V9 MR-372-J84-17B050$799.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
AC079
ACTUATOR STATIC TEST
NOTESThere must be no present or stored faults.
Switch the ignition on and run command AC079 Actuator static test.
If the following actuators are not working, apply the interpretation of the associated fault:
– Fuel pump relay, apply the interpretation of DF085 Fuel pump relay circuit.
– The motorised throttle, apply the interpretation of DF079 Motorised throttle valve servo control.
– The electric coolant pump, apply the interpretation of DF570 Coolant pump relay.
–Upstream O
2 sensor heating, apply the interpretation of DF601 Upstream O2 sensor heating power circuit.
– Downstream O
2 sensor heating, apply the interpretation of DF602 Downstream O2 sensor heating power
circuit.
AFTER REPAIRRepeat the conformity check from the start.