62A - 9
AIR CONDITIONING
Fault finding - Mode of operation62A
V4MR-372-J84-62A000$010.mif
Exchanges between the four air conditioning system computers
–air conditioning request 1 (compressor
engagement)
–switch on passenger compartment heating
resistors (RCH) request
–switch on heated rear screen request
(+ electric door mirrors)
–passenger compartment ventilation signal
Climate
control panelUCH
–passenger compartment heating resistors (RCH)
operation management
–exterior temperature signal
–engine coolant temperature signal
–switch on heated rear screen request
(+ electric door mirrors)
UCHUPC
(Power and Switching Unit)
–alternator charge signal
–number of passenger compartment heating
resistors authorised by alternator
–air conditioning request 2 (compressor
engagement)
–fast idle request for passenger compartment
heating resistors (RCH)
UCHInjection computer
–compressor engagement authorisation
–engine coolant temperature signal
–refrigerant fluid pressure signal
–number of passenger compartment heating
resistors authorised by injection
–compressor engagement request
–switch on engine cooling fan request
Injection computerUPC
(Power and Switching Unit)
–alternator charge signal
Manual air conditioning
and
Climate control
CLIM X84 1.1
Edition 2
MR-372-J84-62A000$040.mif
62A - 14
AIR CONDITIONING
Fault finding - Mode of operation62A
V4MR-372-J84-62A000$010.mif
Manual air conditioning
and
Climate control
Summary of components controlled or managed by the injection computer
Refrigerant fluid
pressure sensorEngine coolant
temperature
sensorVehicle
multiplex
network
Sensor management
Engine injection computer
Management of the cold loop (refrigerant fluid pressure,
switch on engine cooling fan request, compressor
engagement authorisation, etc.)Passenger compartment
heating resistors (RCH)
authorised power
management
Key:
Wire connections =
Multiplex connections =
CLIM X84 1.1
Edition 2
MR-372-J84-62A000$040.mif
62A - 17
AIR CONDITIONING
Fault finding - Conformity check62A
V4
Manual air conditioning
and
Climate controlAIR CONDITIONING
Fault finding - Conformity check
Subsystem: cold loop
NOTESOnly carry out this conformity check after a full check with the diagnostic tool (fault
reading and configuration checks).
Test conditions: ignition on (12
volts APC), engine stopped, AIR CONDITIONING
SWITCHED OFF (passenger compartment blower switched off and air conditioning
compressor not engaged).
NOTE: To check that the temperature parameters are correct (without a thermometer),
read these parameters when the vehicle is cold (in the morning). The temperatures
should be approximately equal (interior, exterior and engine coolant).
Fault finding procedures for the statuses, parameters and commands listed in this
check are explained in the Technical Notes relating to the computer which generates
the signal (see the Introduction section).
Computer
(signal generator)Parameter or status
checked or actionDisplay and Notes Fault finding
Climate controlET143:Air conditioning
request 1.ACTIVE for air conditioning
request (AC button pressed
or AUTO button pressed
with "maximum cold"
request).
INACTIVE otherwise.
NOTE: This status is only
valid for climate control
systems.If there is a fault, refer to the
fault finding procedure
for this status.
NOTE: This status
represents the request from
the climate control
computer to the UCH to
engage the compressor
(refer to the flowchart in
the general operation
section).
PR001:Interior
temperature.X = interior temperature
± 5 ˚C
(invalid value: 87.5 ˚C)If there is a fault, refer to the
fault finding procedure
for this parameter.
ET141:Passenger
compartment
blower.STOPPED
(according to test
conditions: see Notes).If there is a fault, refer to the
fault finding procedure
for this status.
NOTE: This status is only
operative for climate
control systems.
PR012:Mixing flap
position.0% = Max. cold position
(15 ˚C)
100% = Max. warm position
(27 ˚C)If there is a fault, refer to the
fault finding procedure
for this parameter.
PR006:Solar radiation.0 watts (no solar radiation)
to 400 watts (maximum
solar radiation).If there is a fault, refer to the
fault finding procedure
for this parameter.
CLIM X84 1.1
Edition 2
MR-372-J84-62A000$060.mif
62A - 18
AIR CONDITIONING
Fault finding - Conformity check62A
V4
Manual air conditioning
and
Climate control
Subsystem: cold loop (continued 1)
Computer
(signal generator)Parameter or status
checked or actionDisplay and Notes Fault finding
UCHET030:Air conditioning
request 2.INACTIVE
(engagement of the
compressor is only
authorised when the engine
is running).If there is a fault, refer to the
fault finding procedure
for this status.
NOTE: This status
represents the request from
the UCH to the injection
computer to engage the
compressor (refer to the
flowchart in the general
operation section).
PR002:Exterior
temperature.X = exterior temperature
± 5 ˚C
(invalid value: 215 ˚C)If there is a fault, refer to the
fault finding procedure
for this parameter.
ET015:Passenger
compartment
blower.INACTIVE
(according to test
conditions: see Notes).If there is a fault, refer to the
fault finding procedure
for this status.
NOTE: This status is only
operative for manual air
conditioning (and heating
versions without air
conditioning).
ET091:Engine running.NO
NOTE: This status is
displayed by the UCH but it
is generated by the injection
computer.If there is a fault, refer to the
fault finding procedure
for this status.
(Injection Technical Note).
InjectionET079:Air conditioning
present.YES
(automatic injection
computer configuration).If the status displays NO,
refer to the fault finding
procedure for this status.
PR064:Coolant
temperature.X = engine coolant
temperature.If there is a fault, refer to the
fault finding procedure
for this parameter.
ET004:Air conditioning
authorisation.NO
(no authorisation with
engine stopped).If there is a fault, refer to the
fault finding procedure
for this status.
CLIM X84 1.1
Edition 2
MR-372-J84-62A000$060.mif
62A - 22
AIR CONDITIONING
Fault finding - Conformity check62A
V4
Manual air conditioning
and
Climate control
Subsystem: heating
NOTESOnly carry out this conformity check after a full check with the diagnostic tool (fault
reading and configuration checks).
Test conditions: ignition on (12
volts APC), engine stopped, AIR CONDITIONING
SWITCHED OFF (passenger compartment blower switched off and air conditioning
compressor not engaged).
NOTE: To check that the temperature parameters are correct (without a thermometer),
read these parameters when the vehicle is cold (in the morning). The temperatures
should be approximately equal (interior, exterior and engine coolant).
Fault finding procedures for the statuses, parameters and commands listed in this
check are explained in the Technical Notes relating to the computer which generates
the signal (see the Introduction section).
Computer
(signal generator)Parameter or status
checked or actionDisplay and Notes Fault finding
Climate controlET086:Heated rear
screen: manual
mode.ACTIVE: De-icing button at
the bottom of the control
panel pressed.
INACTIVE otherwise.If there is a fault, refer to the
fault finding procedure
for this status.
ET085:Heated rear
screen: auto
mode.ACTIVE: De-icing button at
the top of the control panel
pressed ("See clear"
function).
INACTIVE otherwise.If there is a fault, refer to the
fault finding procedure
for this status.
PR121:Blown air
temperature
setpoint.0 < X < 80 ˚C.If there is a fault, refer to the
fault finding procedure
for this parameter.
PR001:Interior
temperature.X = interior temperature
± 5 ˚C
(invalid value: 87.5 ˚C).If there is a fault, refer to the
fault finding procedure
for this parameter.
PR012:Mixing flap
position.0 % = Max. cold position (15
˚C)
100 % = Max. hot position
(27 ˚C)If there is a fault, refer to the
fault finding procedure
for this parameter.
ET141:Passenger
compartment
blower.OFF
(according to test
conditions: see Notes).If there is a fault, refer to the
fault finding procedure
for this status.
NOTE: This status is only
operative for climate
control systems.
CLIM X84 1.1
Edition 2
MR-372-J84-62A000$060.mif
62A - 25
AIR CONDITIONING
Fault finding - Conformity check62A
V4
Manual air conditioning
and
Climate control
Subsystem: heating (continued 3)
Computer
(signal generator)Parameter or status
checked or actionDisplay and Notes Fault finding
InjectionET024:Set number of
RCH.NO
NOTE: According to the
injection's requirements:
power requirement, torque
reduction, etc., the injection
computer sets the number
of RCH stages switched on
(no more, no less).If there is a fault, refer to the
fault finding procedure
for this status.
PR064:Coolant
temperature.X = engine coolant
temperature.If there is a fault, refer to the
fault finding procedure
for this parameter.
Protection and
Switching UnitPR002:Alternator charge
signal99 %, engine stopped.If there is a fault, refer to the
fault finding procedure
for this parameter.
AC011:Heated rear
screen.Command for testing the
operation of the rear screen
heating.If there is a fault, consult the
fault finding procedure
for this command.
NOTE: The UPC cannot
test the heated rear screen
control circuit; this
command is the only way to
test its operation.
CLIM X84 1.1
Edition 2
MR-372-J84-62A000$060.mif
62A - 28
AIR CONDITIONING
Fault finding - Conformity check62A
V4
Manual air conditioning
and
Climate control
Subsystem: passenger compartment ventilation
NOTESOnly carry out this conformity check after a full check with the diagnostic tool (fault
reading and configuration checks).
Test conditions: ignition on (12
volts APC), engine stopped, AIR CONDITIONING
SWITCHED OFF (passenger compartment blower switched off and air conditioning
compressor not engaged).
NOTE: To check that the temperature parameters are correct (without a thermometer),
read these parameters when the vehicle is cold (in the morning). The temperatures
should be approximately equal (interior, exterior and engine coolant). Fault finding
procedures for the statuses, parameters and commands listed in this check are
explained in the Technical Notes relating to the computer which generates the signal
(see the Introduction section).
Computer
(signal generator)Parameter or status
checked or actionDisplay and Notes Fault finding
Climate controlPR019:Passenger
compartment
blower PWM
setpoint.Speed 0 = 0 %.
Speed 8 = 100 %.
NOTE: The "PWM" signal is
a modulated control voltage
used to control the
passenger compartment
blower power module.If there is a fault or for more
information (to find the
intermediate speed
percentages), refer to the
fault finding procedure
for this parameter.
PR012:Mixing flap
position.0 % = Max. cold position (15
˚C)
100 % = Max. warm
position (27 ˚C)If there is a fault, refer to the
fault finding procedure
for this parameter.
ET062:Recirculation flap
position.OPEN if the flap is in the
outside air position.
CLOSED if the flap is in the
recirculation position.If there is a fault, refer to the
fault finding procedure
for this status.
PR011:Distribution flap
position.from 0 % to 100 %.
NOTE:
0 % = Full air vents position
100 % = De-icing position.If there is a fault or for more
information (various flap
opening values according
to the user selection), refer
to the fault finding
procedure for this
parameter.
CLIM X84 1.1
Edition 2
MR-372-J84-62A000$060.mif
62A - 30
AIR CONDITIONING
Fault finding - Conformity check62A
V4
Manual air conditioning
and
Climate control
Subsystem: cold loop
NOTESOnly carry out this conformity check after a full check with the diagnostic tool (fault
reading and configuration checks).
Test conditions: engine at idle speed,
AIR CONDITIONING OPERATING (air
conditioning compressor engaged).
NOTE: To check that the temperature parameters are correct (without a thermometer),
read these parameters when the vehicle is cold (in the morning). The temperatures
should be approximately equal (interior, exterior and engine coolant).
Fault finding procedures for the statuses, parameters and commands listed in this
check are explained in the Technical Notes relating to the computer which generates
the signal (see the Introduction section).
Computer
(signal generator)Parameter or status
checked or actionDisplay and Notes Fault finding
Climate controlET143:Air conditioning
request 1.ACTIVE
NOTE: This status is only
valid for climate control
systems.If there is a fault, refer to the
fault finding procedure
for this status.
NOTE: This status
represents the request from
the climate control
computer to the UCH to
engage the compressor
(refer to the flowchart in
the general operation
section).
PR001:Interior
temperature.X = interior temperature
± 5 ˚C
(invalid value: 87.5 ˚C)If there is a fault, refer to the
fault finding procedure
for this parameter.
ET141:Passenger
compartment
blower.RUNNING
(according to test
conditions: see Notes).If there is a fault, refer to the
fault finding procedure
for this status.
NOTE: This status is only
operative for climate
control systems.
PR012:Mixing flap
position.0% = Max. cold position
(15 ˚C)
100% = Max. warm position
(27 ˚C)If there is a fault, refer to the
fault finding procedure
for this parameter.
PR006:Solar radiation. 0 watts (no solar radiation)
to 400 watts (maximum
solar radiation).If there is a fault, refer to the
fault finding procedure
for this parameter.
CLIM X84 1.1
Edition 2
MR-372-J84-62A000$060.mif