P0442 EVAP CONTROL SYSTEMEC-281
< COMPONENT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
2. Does water drain from the EVAP canister?
Does water drain from
the EVAP canister?
YES >> GO TO 9.
NO-1 >> With CONSULT-III: GO TO 11.
NO-2 >> Without CONSULT-III: GO TO 12.
9.CHECK EVAP CANISTER
Weigh the EVAP canister with the EVAP canister vent control valve and EVAP control system pressure sensor
attached.
The weight should be less than 1.9 kg (4.2 lb).
Is the inspection result normal?
YES-1 >> With CONSULT-III: GO TO 11.
YES-2 >> Without CONSULT-III: GO TO 12.
NO >> GO TO 10.
10.DETECT MALFUNCTIONING PART
Check the following.
• EVAP canister for damage
• EVAP hose between EVAP canister and vehi cle frame for clogging or poor connection
>> Repair hose or replace EVAP canister.
11 .CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
With CONSULT-III
1. Disconnect vacuum hose to EVAP canister purge volu me control solenoid valve at EVAP service port.
2. Start engine.
3. Perform “PURG VOL CONT/V ” in “ACTIVE TEST” mode.
4. Touch “Qu” on CONSULT-III screen to increase “PURG VOL C/V” opening to 100%.
5. Check vacuum hose for vacuum.
Is the inspection result normal?
YES >> GO TO 14.
NO >> GO TO 13.
12.CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
Without CONSULT-III
1. Start engine and warm it up to normal operating temperature.
2. Stop engine.
3. Disconnect vacuum hose to EVAP canister purge volu me control solenoid valve at EVAP service port.
4. Start engine and let it idle for at least 80 seconds.
5. Check vacuum hose for vacuum when revving engine up to 2,000 rpm.
Is the inspection result normal?
YES >> GO TO 14.
NO >> GO TO 13.
13.CHECK VACUUM HOSE
Check vacuum hoses for clogging or disconnection. Refer to EC-68, "
System Description".
Is the inspection result normal?
PBIB1213E
Vacuum should exist.
Vacuum should exist.
Revision: January 20102010 Versa
EC-286
< COMPONENT DIAGNOSIS >[HR16DE]
P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
With CONSULT-III
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON.
4. Select “PURG VOL CN/V P1444” of “EVAPORATIVE SYSTEM” in “DTC WORK SUPPORT” mode with
CONSULT-III.
5. Touch “START”.
6. Start engine and let it idle until “TESTING” on CONSULT-III changes to “COMPLETED”. (It will take approximately 10 seconds.)
If “TESTING” is not displayed after 5 minutes, retry from step 2.
7. Touch “SELF-DIAG RESULTS”.
Which is displayed on CONSULT-III screen?
OK >> INSPECTION END
NG >> Go to EC-287, "
Diagnosis Procedure".
4.PERFORM DTC CONFIRMATION PROCEDURE A
With GST
1. Turn ignition switch ON.
2. Set voltmeter probes to ECM harness connector terminals.
3. Check that the voltage is 3.1 - 4.0 V.
4. Start engine and wait at least 60 seconds.
5. Check 1st trip DTC.
Is 1st trip DTC detected?
YES >> Go to EC-287, "Diagnosis Procedure".
NO >> GO TO 5.
5.PERFORM DTC CONFIRMATION PROCEDURE B
With GST
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Start engine and let it idle for at least 20 seconds.
4. Check 1st trip DTC.
Is 1st trip DTC displayed?
YES >> Go to EC-287, "Diagnosis Procedure".
NO >> INSPECTION END
ECM Ground
Connector Terminal
F11 43
(Fuel tank temperature sensor signal) Ground
SEF113U
Revision: January 20102010 Versa
P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-289
< COMPONENT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
2. Reconnect harness connectors disconnected.
3. Start engine.
4. Perform “PURG VOL CONT/V” in
“ACTIVE TEST” mode with CONSULT-III. Check that engine speed var-
ies according to the valve opening.
Is the inspection result normal?
YES >> GO TO 8.
NO >> GO TO 7.
7.CHECK EVAP CANISTER PURGE VO LUME CONTROL SOLENOID VALVE
Refer to EC-290, "
Component Inspection".
Is the inspection result normal?
YES >> GO TO 8.
NO >> Replace EVAP canister purge volume control solenoid valve.
8.CHECK RUBBER TUBE FOR CLOGGING
1. Disconnect rubber tube connected to EV AP canister vent control valve.
2. Check the rubber tube for clogging.
Is the inspection result normal?
YES >> GO TO 9.
NO >> Clean the rubber tube using an air blower.
9.CHECK EVAP CANISTER VENT CONTROL VALVE
Refer to EC-298, "
Component Inspection".
Is the inspection result normal?
YES >> GO TO 10.
NO >> Replace EVAP canister vent control valve.
10.CHECK IF EVAP CANISTER IS SATURATED WITH WATER
1. Remove EVAP canister with EVAP canister vent c ontrol valve and EVAP control system pressure sensor
attached.
2. Check if water will drain from EVAP canister.
Does water drain from the EVAP canister?
YES >> GO TO 11.
NO >> GO TO 13.
11 .CHECK EVAP CANISTER
Weigh the EVAP canister with the EVAP canister vent control valve and EVAP control system pressure sensor
attached.
The weight should be less than 1.9 kg (4.2 lb).
Is the inspection result normal?
YES >> GO TO 13.
NO >> GO TO 12.
12.DETECT MALFUNCTIONING PART
Check the following.
• EVAP canister for damage
• EVAP hose between EVAP canister and vehi cle frame for clogging or poor connection
>> Repair hose or replace EVAP canister.
13.CHECK INTERMITTENT INCIDENT
PBIB1213E
Revision: January 20102010 Versa
EC-290
< COMPONENT DIAGNOSIS >[HR16DE]
P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Refer to
EC-114, "Diagnosis Procedure".
>> INSPECTION END
Component InspectionINFOID:0000000005398449
1.CHECK EVAP CANISTER PURGE VO LUME CONTROL SOLENOID VALVE
With CONSULT-III
1. Turn ignition switch OFF.
2. Reconnect all harness connectors disconnected.
3. Disconnect EVAP purge hoses connected to EVAP canister purge volume control solenoid valve.
4. Turn ignition switch ON.
5. Select “PURG VOL CONT/V” in “A CTIVE TEST” mode with CONSULT-III.
6. Touch “Qd” and “Qu” on CONSULT-III screen to adjust “PURG VOL C/V” opening and check air passage continuity of EVAP
canister purge volume control solenoid valve under the following
conditions.
Without CONSULT-III
1. Turn ignition switch OFF.
2. Disconnect EVAP canister purge volume control solenoid valve harness connector.
3. Disconnect EVAP purge hoses connected to EVAP canister purge volume control solenoid valve.
4. Check air passage continuity of EVAP canister purge volume control solenoid valve under the following conditions.
Is the inspection result normal?
YES >> INSPECTION END
NO >> Replace EVAP canister purge volume control solenoid valve
Condition
(PURG VOL C/V value) Air passage continuity
between (A) and (B)
100% Existed
0% Not existed
PBIA9668J
ConditionAir passage continuity
between (A) and (B)
12 V direct current supply between
terminals 1 and 2 Existed
No supply Not existed
PBIA9560J
Revision: January 20102010 Versa
P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID
VALVE
EC-293
< COMPONENT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
4. Check the voltage between EVAP canister purge volume control
solenoid valve harness connector and ground.
Is the inspection result normal?
YES >> GO TO 3.
NO >> GO TO 2.
2.DETECT MALFUNCTIONING PART
Check the following.
• IPDM E/R harness connector E43
• Harness connectors E8, F8
• Harness for open or short between EVAP canister purge volume control solenoid valve and IPDM E/R
• Harness for open or short between EVAP canister purge volume control solenoid valve and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
3.CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT
FOR OPEN AND SHORT1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check the continuity between EVAP canister pur ge volume control solenoid valve harness connector and
ECM harness connector.
4. Also check harness for short to ground and short to power.
Is the inspection result normal?
YES-1 >> With CONSULT-III: GO TO 4.
YES-2 >> Without CONSULT-III: GO TO 5.
NO >> Repair open circuit or short to ground or short to power in harness or connectors.
4.CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
With CONSULT-III
1. Reconnect all harness connectors disconnected.
2. Start engine.
3. Perform “PURG VOL CONT/V” in “ACTIVE TEST” mode with CONSULT-III. Check that engine speed var-
ies according to the valve opening.
Is the inspection result normal?
YES >> GO TO 6.
NO >> GO TO 5.
5.CHECK EVAP CANISTER PURGE VO LUME CONTROL SOLENOID VALVE
Refer to EC-294, "
Component Inspection".
Is the inspection result normal?
YES >> GO TO 6.
NO >> Replace EVAP canister purge volume control solenoid valve.
6.CHECK INTERMITTENT INCIDENT
Refer to EC-114, "
Diagnosis Procedure".
EVAP canister purge volume
control solenoid valve Ground Voltage
Connector Terminal
F22 1 Ground Battery voltage
SEF206W
EVAP canister purge volume
control solenoid valve ECM
Continuity
Connector Terminal Connector Terminal
F22 2F10 9Existed
Revision: January 20102010 Versa
EC-294
< COMPONENT DIAGNOSIS >[HR16DE]
P0444, P0445 EVAP CANISTER P
URGE VOLUME CONTROL SOLENOID
VALVE
>> INSPECTION END
Component InspectionINFOID:0000000005398454
1.CHECK EVAP CANISTER PURGE VO LUME CONTROL SOLENOID VALVE
With CONSULT-III
1. Turn ignition switch OFF.
2. Reconnect all harness connectors disconnected.
3. Disconnect EVAP purge hoses connected to EVAP canister purge volume control solenoid valve.
4. Turn ignition switch ON.
5. Select “PURG VOL CONT/V” in “A CTIVE TEST” mode with CONSULT-III.
6. Touch “Qd” and “Qu” on CONSULT-III screen to adjust “PURG
VOL C/V” opening and check air passage continuity of EVAP
canister purge volume control solenoid valve under the following
conditions.
Without CONSULT-III
1. Turn ignition switch OFF.
2. Disconnect EVAP canister purge volume control solenoid valve harness connector.
3. Disconnect EVAP purge hoses connected to EVAP canister purge volume control solenoid valve.
4. Check air passage continuity of EVAP canister purge volume control solenoid valve under the following conditions.
Is the inspection result normal?
YES >> INSPECTION END
NO >> Replace EVAP canister purge volume control solenoid valve
Condition
(PURG VOL C/V value) Air passage continuity
between (A) and (B)
100% Existed
0% Not existed
PBIA9668J
ConditionAir passage continuity
between (A) and (B)
12 V direct current supply between
terminals 1 and 2 Existed
No supply Not existed
PBIA9560J
Revision: January 20102010 Versa
EC-298
< COMPONENT DIAGNOSIS >[HR16DE]
P0447 EVAP CANISTER VENT CONTROL VALVE
• Harness connectors E7, M69
• Harness connectors M13, B102
• Harness for open or short between EVAP canister vent control valve and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
7.CHECK RUBBER TUBE FOR CLOGGING
1. Disconnect rubber tube connected to EV AP canister vent control valve.
2. Check the rubber tube for clogging.
Is the inspection result normal?
YES >> GO TO 8.
NO >> Clean the rubber tube using an air blower.
8.CHECK EVAP CANISTER VENT CONTROL VALVE
Refer to EC-298, "
Component Inspection".
Is the inspection result normal?
YES >> GO TO 9.
NO >> Replace EVAP canister vent control valve.
9.CHECK INTERMITTENT INCIDENT
Refer to EC-114, "
Diagnosis Procedure".
>> INSPECTION END
Component InspectionINFOID:0000000005398459
1.CHECK EVAP CANISTER VENT CONTROL VALVE-I
1. Turn ignition switch OFF.
2. Remove EVAP canister vent control valve from EVAP canister.
3. Check portion (A) of EVAP canister vent control valve for being rusted.
Is it rusted?
YES >> Replace EVAP canister vent control valve.
NO >> GO TO 2.
2.CHECK EVAP CANISTER VENT CONTROL VALVE-II
With CONSULT-III
1. Reconnect harness connectors disconnected.
2. Turn ignition switch ON.
3. Perform “VENT CONTROL/V” in “ACTIVE TEST” mode.
4. Check air passage continuity and operation delay time. Make sure new O-ring is installed properly.
Operation takes less than 1 second.
Without CONSULT-III
Check air passage continuity and operation delay time under the fol-
lowing conditions.
Make sure new O-ring is installed properly.
JMBIA0168ZZ
VENT CONT/V condition Air passage continuity between (A) and (B)
ON Not existed
OFF Existed
JMBIA0169ZZ
Revision: January 20102010 Versa
P0447 EVAP CANISTER VENT CONTROL VALVEEC-299
< COMPONENT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
Operation takes less than 1 second.
Is the inspection result normal?
YES >> GO TO 3.
NO >> Replace EVAP canister vent control valve.
3.CHECK EVAP CANISTER VENT CONTROL VALVE-III
With CONSULT-III
1. Clean the air passage [portion (A) to (B)] of EVAP canister vent control valve using an air blower.
2. Perform “VENT CONTROL/V” in “ACTIVE TEST” mode.
3. Check air passage continuity and operation delay time. Make sure new O-ring is installed properly.
Operation takes less than 1 second.
Without CONSULT-III
1. Clean the air passage [portion (A) to (B)] of EVAP canister vent control valve using an air blower.
2. Check air passage continuity and operation delay time under the following conditions.
Make sure new O-ring is installed properly.
Operation takes less than 1 second.
Is the inspection result normal?
YES >> INSPECTION END
NO >> Replace EVAP canister vent control valve.
Condition Air passage continuity between (A) and (B)
12 V direct current supply between
terminals (1) and (2) Not existed
OFF Existed
VENT CONT/V condition Air passage continuity between (A) and (B)
ON Not existed
OFF Existed
Condition Air passage continuity between (A) and (B)
12 V direct current supply between
terminals (1) and (2) Not existed
OFF Existed
JMBIA0169ZZ
Revision: January 20102010 Versa