2009 RENAULT TWINGO light

[x] Cancel search: light

Page 42 of 138

RENAULT TWINGO 2009 2.G Sequential Transmission Workshop Manual 21B-42
MR-413-X44-21B000$413.mif
V2
SEQUENTIAL GEARBOX
Fault finding - Interpretation of faults
Vdiag No.: 04
21B
DF076
PRESENT
OR
STOREDCLUTCH CONTROL
1.DEF: Clutch inconsistency upon gear change
NOT

Page 43 of 138

RENAULT TWINGO 2009 2.G Sequential Transmission Workshop Manual 21B-43
MR-413-X44-21B000$413.mif
V2
SEQUENTIAL GEARBOX
Fault finding - Interpretation of faults
Vdiag No.: 04
21B
DF077
PRESENT
OR
STOREDGEARBOX CONTROL
1.DEF: Impossible to engage or disengage a gear

Page 45 of 138

RENAULT TWINGO 2009 2.G Sequential Transmission Workshop Manual 21B-45
MR-413-X44-21B000$413.mif
V2
SEQUENTIAL GEARBOX
Fault finding - Interpretation of faults
Vdiag No.: 04
21B
DF080
PRESENT
OR
STOREDBATTERY VOLTAGE
1.DEF: Battery undervoltage
NOTESSpecial notes:

Page 46 of 138

RENAULT TWINGO 2009 2.G Sequential Transmission Workshop Manual 21B-46
MR-413-X44-21B000$413.mif
V2
SEQUENTIAL GEARBOX
Fault finding - Interpretation of faults
Vdiag No.: 04
21B
DF082
PRESENT
OR
STOREDBRAKE LIGHTS SWITCH CIRCUIT
1.DEF: Signal incoherent
NOTESSpeci

Page 47 of 138

RENAULT TWINGO 2009 2.G Sequential Transmission Workshop Manual 21B-47
MR-413-X44-21B000$413.mif
V2
SEQUENTIAL GEARBOX
Fault finding - Interpretation of faults
Vdiag No.: 04
21B
DF107
PRESENT
OR
STOREDENGINE SPEED MULTIPLEX SIGNAL
1.DEF: Communication disrupted
NO

Page 54 of 138

RENAULT TWINGO 2009 2.G Sequential Transmission Workshop Manual 21B-54
MR-413-X44-21B000$472.mif
V2
SEQUENTIAL GEARBOX
Fault finding - Interpretation of faults
Vdiag No: 04
21B
DF145
PRESENT
OR
STOREDINVALID PEDAL POSITION MULTIPLEX SIGNAL
1.DEF :  Communication d

Page 57 of 138

RENAULT TWINGO 2009 2.G Sequential Transmission Workshop Manual 21B-57
MR-413-X44-21B000$472.mif
V2
SEQUENTIAL GEARBOX
Fault finding - Interpretation of faults
Vdiag No: 04
21B
DF148
PRESENT
OR
STOREDSECONDARY BRAKE CONTACT MULTIPLEX SIGNAL
1.DEF :  Communication

Page 59 of 138

RENAULT TWINGO 2009 2.G Sequential Transmission Workshop Manual 21B-59
MR-413-X44-21B000$472.mif
V2
SEQUENTIAL GEARBOX
Fault finding - Interpretation of faults
Vdiag No: 04
21B
DF166
PRESENT
OR
STOREDPRESSURE SENSOR CIRCUIT
CO.0 :  Open circuit or short circuit to