Page 19 of 63
62C-19
MR-413-X44-62C000$455_eng.mif
V1
MANUAL AIR CONDITIONING
Fault finding - Function62C
Vehicle
multiplex
network
Summary diagram of components controlled or managed by the UCH:
Summary diagram of components controlled or managed by the injection computer Rear screen de-icing and
rear-view mirror de-icer
(depending on version)External temperature
sensor
(depending on
version)
Actuator control Sensor management
UCH
Air conditioning request
managementHeated rear screen control
management
Relay No. 1 for
the Passenger
Compartment
Heating
ResistorsRelay No. 2 for
the Passenger
Compartment
Heating
ResistorsAir conditioning
compressorEngine cooling
fan assemblyEngine
coolant
temperature
sensorRefrigerant
fluid
pressure
sensor
Actuator control Sensor management
Engine injection computer
Management of the cold loop (refrigerant pressure, engine cooling fan activation request,
compressor activation authorisation, etc.)
Key:
Wire connections =
Multiplex connections =
Page 21 of 63
62C-21
MR-413-X44-62C000$546_eng.mif
V1
62C
MANUAL AIR CONDITIONING
Diagnostics - Configuration and programming
Air conditioning system configurations
Air conditioning system configuration readingsComputers Configuration Option Comments
UCHCF019: Type of air
conditioning– Heating
– Manual
– Climate control
CF029: Exterior
temperature
sensor–With
–None
INJECTION (all types) X XAutomatic computer
configuration
Computers Configuration readings Option Comments
UCHLC013: Type of air
conditioning– Climate control
– Manual air
conditioning
– Heating
None
LC002: External
temperature
sensor– With
– None
MR-413-X44-62C000$546_eng.mif
Page 25 of 63

62C-25
MR-413-X44-62C000$637_eng.mif
V1
MANUAL AIR CONDITIONING
Fault finding - Conformity check62C
SUB-FUNCTION: HEATING
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(fault reading and configuration checks).
Application conditions: engine stopped, ignition on, AIR CONDITIONING
SWITCHED OFF (Passenger compartment blower unit switched off and air
conditioning compressor not activated).
ComputerParameter or Status
checked or ActionDisplay and Notes Fault finding
UCH (see 87B,
Passenger
compartment
connection unit)ET015:Passenger
compartment
blowerINACTIVE
(according to test
conditions: see Notes).In the event of a fault, refer to the
interpretation of this status.
PR001:Battery voltage10.5 V < X <14.4 VIf there is a fault, refer to the
interpretation of this
parameter If the fault is still
present, carry out fault finding on
the charging circuit (see MR 411
Mechanical, 16A, Starting -
Charging).
PR002:Exterior
temperature
(depending on
the version)X = exterior
temperature ±± ± ±
5 ˚C
(invalid value: 215 ˚C).If there is a fault, refer to the
interpretation of this
parameter
PR024:Engine coolant
temperatureX = engine coolant
temperature in ˚C.If there is a fault, refer to the
interpretation of this
parameter
ET239:Ignition switch
position+ after ignition feedIn the event of a fault, refer to the
interpretation of this status.
PR025:Engine speed0 rpmIf there is a fault, refer to the
interpretation of this
parameter
Page 26 of 63

62C-26
MR-413-X44-62C000$637_eng.mif
V1
MANUAL AIR CONDITIONING
Fault finding - Conformity check62C
SUB-FUNCTION: HEATING (CONTINUED)
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(fault reading and configuration checks).
Application conditions: engine stopped, ignition on, AIR CONDITIONING
SWITCHED OFF (Passenger compartment blower unit switched off and air
conditioning compressor not activated).
ComputerParameter or Status
checked or ActionDisplay and Notes Fault finding
Injection (see 13B,
Diesel injection or
17B, Petrol
injection)PR064:Coolant
temperatureX = engine coolant
temperatureIf there is a fault, refer to the
interpretation of this
parameter
ET111:RCH number setNO
Note: Depending on the
requirements of the
injection system (power
requirement, torque
reduction, etc.), the
injection computer sets
the controlled
passenger compartment
heating resistor stage
number (no more, no
less)In the event of a fault, refer to the
interpretation of this status.
ET112:Passenger
compartment
heating resistor
cut-offYESIn the event of a fault, refer to the
interpretation of this status.
Page 27 of 63

62C-27
MR-413-X44-62C000$637_eng.mif
V1
MANUAL AIR CONDITIONING
Fault finding - Conformity check62C
SUB-FUNCTION: USER SELECTION
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(fault reading and configuration checks).
Application conditions: engine stopped, ignition on, AIR CONDITIONING
SWITCHED OFF (Passenger compartment blower unit switched off and air
conditioning compressor not activated).
ComputerParameter or Status
checked or ActionDisplay and Notes Fault finding
UCH (see 87B,
Passenger
compartment
connection unit)ET028:Heated rear
screen buttonPRESSED if the heated
rear screen key on the
air conditioning control
panel is pressed.
RELEASED otherwise.In the event of a fault, refer to the
interpretation of this status.
Note:
This status only operates for
manual air conditioning and
heating versions.
ET029:Air conditioning
buttonPRESSED if the AC
button on the air
conditioning control
panel is pressed.
RELEASED otherwise.In the event of a fault, refer to the
interpretation of this status.
ET015:Passenger
compartment
blowerINACTIVE
(according to test
conditions: see Notes).In the event of a fault, refer to the
interpretation of this status.
Note:
This status only operates for
manual air conditioning and
heating versions.
Page 28 of 63

62C-28
MR-413-X44-62C000$637_eng.mif
V1
MANUAL AIR CONDITIONING
Fault finding - Conformity check62C
SUB-FUNCTION: COLD LOOP
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(fault reading and configuration checks).
Application conditions: engine at idle speed, AIR CONDITIONING OPERATING
(air conditioning compressor engaged).
ComputerParameter or Status
checked or ActionDisplay and Notes Fault finding
UCH (see 87B,
Passenger
compartment
connection unit)PR002:Exterior
temperature
(depending on
the version)X = exterior temperature
± 5 ˚C (invalid value:
215 ˚C)In the event of a fault, see the
interpretation of this
parameter.
ET142:Engine
operating phaseRUNNING
Note: this status is
displayed by the UCH
but is produced by the
injection computer.In the event of a fault, refer to the
interpretation of this status
(see the INJECTION technical
note).
ET030:Air conditioning
request 2ACTIVEIn the event of a fault, refer to the
interpretation of this status.
Note:
This status represents the
request from the UCH to the
injection computer to activate the
compressor (refer to the
flowchart in the Configuration
and Programming section).
ET015:Passenger
compartment
blowerACTIVE
(according to test
conditions: see Notes).In the event of a fault, refer to the
interpretation of this status.
Note:
This status only operates for
manual air conditioning and
heating versions.
PR025:Engine speed800 rpm ± 50 rpmIn the event of a fault, see the
interpretation of this
parameter.
Page 31 of 63

62C-31
MR-413-X44-62C000$637_eng.mif
V1
MANUAL AIR CONDITIONING
Fault finding - Conformity check62C
SUB-FUNCTION: HEATING
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(fault reading and configuration checks).
Application conditions: engine at idle speed, AIR CONDITIONING OPERATING
(air conditioning compressor engaged).
ComputerParameter or Status
checked or ActionDisplay and Notes Fault finding
UCH (continued)
(see 87B,
Passenger
compartment
connection unit)ET239:Ignition switch
position+ after ignition feedIn the event of a fault, refer to the
interpretation of this status.
PR025:Engine speed800 rpm ± 50 rpmIn the event of a fault, see the
interpretation of this
parameter.
PR024:Engine coolant
temperatureX = engine coolant
temperatureIn the event of a fault, see the
interpretation of this
parameter.
ET015:Passenger
compartment
blowerACTIVE
(according to test
conditions: see Notes).In the event of a fault, refer to the
interpretation of this status.
Note: This status only operates
for manual air conditioning and
heating versions.
PR001:Battery voltage12.5 V < X < 14.4 VIn the event of a fault, see the
interpretation of this
parameter.
If the fault is still present, carry
out fault finding on the charging
circuit (see MR 411 Mechanical,
16A, Starting - Charging).
PR002:Exterior
temperature
(depending on
the version)X = exterior
temperature ±± ± ±
5 ˚C
(invalid value: 215 ˚C).In the event of a fault, see the
interpretation of this
parameter.
Page 32 of 63

62C-32
MR-413-X44-62C000$637_eng.mif
V1
MANUAL AIR CONDITIONING
Fault finding - Conformity check62C
SUB-FUNCTION: HEATING
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(fault reading and configuration checks).
Application conditions: engine at idle speed, AIR CONDITIONING OPERATING
(air conditioning compressor engaged).
ComputerParameter or Status
checked or ActionDisplay and Notes Fault finding
Injection (see 13B,
Diesel injection or
17B, Petrol
injection)PR064:Coolant
temperatureX = engine coolant
temperatureIn the event of a fault, see the
interpretation of this
parameter.
ET111:RCH number setYES or NO
Note: Depending on the
requirements of the
injection system (power
requirement, torque
reduction, etc.), the
injection computer sets
the controlled
passenger compartment
heating resistor stage
number (no more,
no less)In the event of a fault, refer to the
interpretation of this status.
ET112:RCH cut-offYES or NO
Note: Depending on the
requirements of the
injection system (power
requirement, torque
reduction, etc.), the
injection computer sets
the controlled
passenger compartment
heating resistor stage
number (no more,
no less)In the event of a fault, refer to the
interpretation of this status.