MULTIMEDIA CONNECTION
Fault finding – Introduction86C
CBOX
Vdiag No.: 04
To cut off the + after ignition feed, proceed as follows:
Faults
Faults are declared either present or stored (depending on whether they appeared in a certain context and have
disappeared since, or whether they remain present but have not been diagnosed within the current context).
The present or stored status of faults should be taken into consideration when the diagnostic tool is used after the
+ after ignition feed has been activated (without any of the system components being activated).
For a present fault, apply the procedure described in the Interpretation of faults section.
For a stored fault, note the faults displayed and apply the Notes section.
If the fault is confirmed when the instructions are applied, the fault is present. Deal with the fault.
If the fault is not confirmed, check:
–the electrical lines which correspond to the fault,
–the connectors on these lines (corrosion, bent pins, etc.),
–the resistance of the component detected as faulty,
–the condition of the wires (melted or split insulation, wear).
Conformity check
The aim of the conformity check is to check the data that does not display a fault on the diagnostic tool when the
data is inconsistent. Therefore, this stage is used to:
–carry out fault finding on faults that do not have a fault display, and which may correspond to a customer complaint.
–check that the system is operating correctly and that there is no risk of a fault recurring after repair.
This section gives the fault finding procedures for statuses and parameters and the conditions for checking them.
If a status is not behaving normally or a parameter is outside the permitted tolerance values, consult the
corresponding fault finding page.
Customer complaints - Fault finding chart
If the test with the diagnostic tool is OK but the customer complaint is still present, the fault should be processed by
customer complaints. For vehicles with radio frequency remote control/key, use the key to switch off the ignition.
For vehicles with Renault cards,
Press the Start button twice briefly (less than 3 seconds),
Ensure that the forced + after ignition feed has been cut off by checking that the computer warning lights on the
instrument panel have gone out.
A synopsis of the general procedure to follow is provided on the following page in the form of a flow chart.
86C-20V1 MR-413-X44-86C000$070.mif
86C
CBOX
Vdiag No.: 04
VP003: Write V.I.N
This command permits manual entry of the vehicle's VIN into the computer. Use this command each time
the computer is replaced. The VIN number is inscribed on the manufacturer's plate.
Procedure for writing the VIN
•Establish dialogue with the navigation computer.
•Select the Repair mode menu.
•Select the Other configuration menu.
•Select line VP003 Write VIN.
•Enter the VIN.
•Exit fault finding mode.
•Switch off the ignition.
•Wait for the end of the Powerlatch* phase (20 minutes maximum).
•Reread the VIN in the Identification menu to confirm ID008 VIN code.
VP001: Enter last After-Sales operation date
This command is used to enter the date of the last After-Sales operation on the radio.
Consecutively enter the six figures of the date: two for the year, two for the month and two for the day.
E.g. 000706 (06 July 2000).
Reread the date of the last After-sales operation in the Identification menu to confirm ID012 Last After-Sales
operation date.
*Powerlatch: Time required for injection computer supply after + 12 V after ignition feed cut-off.