83A-59
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
V5 MR-413-X44-83A000$952.mif
INSTRUMENT PANEL
Fault finding - Fault finding chart Vdiag No.: 04, 0883A
Vdiag No.: 04 08
ALP 5Fault with no warning given by warning light (no addition of fuel
since the fault)
NOTESPut the vehicle in + after ignition.
See Wiring diagram Technical Note, New Twingo.
Check the instrument panel warning lights, component
code 247.Replace the instrument panel,
component code 247 (see
MR 411, Mechanical, 83A,
Instrument panel, Instrument
panel: Removal - Refitting). Does the fuel warning light illuminate for 3 seconds when
+ after ignition is switched on?
Record the resistance value provided by the CLIP tool.
Compare the value from the CLIP tool with the warning
resistance, which should be 260 ΩΩ Ω Ω
.
Is this value above or equal to 260 ΩΩ Ω Ω
?Contact the Techline.
Rock the vehicle and check whether the resistance changes by
± 5 ΩΩ Ω Ω
.
Is there a change in the resistance value?Contact the Techline.
NO
YES
YES
NO
YES
NO
A
TDB_V04_ALP5/TDB_V08_ALP5
83A-63
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
V5 MR-413-X44-83A000$952.mif
INSTRUMENT PANEL
Fault finding - Fault finding chart Vdiag No.: 04, 0883A
Vdiag No.: 04 08
ALP 6Fault with no warning given by warning light (addition of fuel
since the fault)
NOTESPut the vehicle in + after ignition.
See Wiring diagram Technical Note, New Twingo.
Check the instrument panel warning lights, component
code 247.
Does the fuel warning light illuminate for 3
seconds when + after ignition is switched on?Replace the instrument panel,
component code 247 (see MR 411,
Mechanical, 83A, Instrument panel,
Instrument panel: Removal -
Refitting).
With the ignition off, disconnect the fuel sender
connector, component code 833 and then check the
resistance using a multimeter.
Compare the value measured to the value supplied by
the CLIP tool.
Is the value measured and the value provided by
the CLIP tool the same as or approximately ± 5 ΩΩ Ω Ω
?
Contact the Techline.
NO
YES
NOB
YES
TDB_V04_ALP6/TDB_V08_ALP6