Page 28 of 67
88C-28
MR-413-X44-88C000$616.mif
V3
AIRBAGS AND PRETENSIONERS
Fault finding - Interpretation of faults
MRSZ AIRBAG
Vdiag: 04
88C
DF028
PRESENT
PASSENGER AIRBAG STATUS WARNING LIGHT CIRCUIT
NOTESSpecial notes:
This fault may be "present" after command AC009 Instrument panel warning lights
is activated on the instrument panel.
Apply the fault finding procedure relevant to this fault in the instrument panel fault finding information section.
Carry out a fault finding procedure on the instrument panel (see 83A, Instrument panel).
AFTER REPAIRClear the computer fault memory using command RZ001 "Fault memory". Switch
the ignition of f and then on again.
Repeat a check using the diagnostic tool and, if there are no faults (do not take the
DF034 "Computer locked'' into account), unlock the computer using the command
VP007 ''Unlock computer''.
ABGMRSZ_V04_DF028P
Page 34 of 67
88C-34
MR-413-X44-88C000$616.mif
V3
AIRBAGS AND PRETENSIONERS
Fault finding - Interpretation of faults
MRSZ AIRBAG
Vdiag: 04
88C
DF060
PRESENT
MULTIPLEX NETWORK
1.DEF: Multiplex network
2.DEF: Initialisation of instrument panel too long
NOTESNone.
Carry out the fault finding procedure for the multiplex network.
Run a multiplex network test (see 88B, Multiplexing).
AFTER REPAIRClear the computer fault memory using command RZ001 "Fault memory". Switch
the ignition of f and then on again.
Repeat a check using the diagnostic tool and, if there are no faults (do not take the
DF034 "Computer locked'' into account), unlock the computer using the command
VP007 ''Unlock computer''.
ABGMRSZ_V04_DF060P
Page 47 of 67
88C-47
MR-413-X44-88C000$616.mif
V3
AIRBAGS AND PRETENSIONERS
Fault finding - Interpretation of faults
MRSZ AIRBAG
Vdiag: 04
88C
DF165
PRESENT
AIRBAG FAULT WARNING LIGHT CIRCUIT
NOTESNone.
Apply the fault finding procedure relevant to this fault in the instrument panel fault finding information section.
Carry out a fault finding procedure on the instrument panel (see 83A, Instrument panel).
AFTER REPAIRReconnect the computer and the locking switch, then switch on the ignition again.
Clear the computer fault memory. Switch off the ignition.
Carry out the check again using the diagnostic tool and, if there is no fault, unlock the
computer.
ABGMRSZ_V04_DF165P
Page 60 of 67
88C-60
MR-413-X44-88C000$616.mif
V3
AIRBAGS AND PRETENSIONERS
Fault finding - Interpretation of faults
MRSZ AIRBAG
Vdiag: 04
88C
DF264
PRESENT
NO INSTRUMENT PANEL MULTIPLEX SIGNAL
1. DEF: No instrument panel multiplex signal
NOTESNone.
Carry out the fault finding procedure for the multiplex network.
Carry out a test on the multiplex network and the instrument panel (see 88B, Multiplexing and 83A, Instrument
panel).
AFTER REPAIRNone.
ABGMRSZ_V04_DF264P