62B-2
MR-413-X44-62B000$046_eng.mif
V1
62B
CLIMATE CONTROL
Fault finding - Introduction
1. SCOPE OF THIS DOCUMENT
This document presents the fault finding procedure applicable to all computers with the following specifications:
2. PREREQUISITES FOR FAULT FINDING
Documentation type
Fault finding procedures (this document and the Technical Notes concerning the injection system fitted to
the vehicle, and the UCH):
–Assisted fault finding (integrated into the diagnostic tool), Dialogys.
Wiring Diagrams:
–Visu-Schéma (CD-ROM), paper.
Type of diagnostic tools
–CLIP + multiplex line sensor
Special tooling required
3. REMINDERS
Procedure
To run fault finding on the vehicle computers, proceed as follows:
–turn the ignition key to APC,
–connect the diagnostic tool and perform the required operations.
To cut off the + after ignition feed, proceed as follows:
–disconnect the diagnostic tool,
–turn the ignition key to OFF,
–switch off the ignition. Vehicle(s): New Twingo
Function concerned: Climate controlComputer name: CAREG
Vdiag No.: 44
Special tooling required
Multimeter
Elé. 1681 Universal bornier
CLIM_V44_PRELI
Vdiag No.: 44
MR-413-X44-62B000$046_eng.mif
62B-3
MR-413-X44-62B000$046_eng.mif
V1
CLIMATE CONTROL
Fault finding - Introduction
Vdiag No.: 44
62B
Faults
Faults are declared as either present or stored (depending on whether they appeared in a certain context and have
disappeared since, or whether they remain present but have not been diagnosed within the current context).
The present or stored status of faults should be taken into consideration when the diagnostic tool is switched on
after the + after ignition feed (without any system components being active).
For a present fault, apply the procedure described in the Interpretation of faults section.
For a stored fault, note the faults displayed and apply the Notes section.
If the fault is confirmed when the instructions in the Notes section are applied, the fault is present. Deal with the
fault.
If the fault is not confirmed, check:
–the electrical lines which correspond to the fault,
–the connectors on these lines (corrosion, bent pins, etc.),
–the resistance of the component detected as faulty,
–the condition of the wires (melted or split insulation, wear).
Conformity check
The aim of the conformity check is to check data that does not produce a fault on the diagnostic tool because the
data is inconsistent. Therefore, this stage is used to:
–carry out fault finding on faults that do not have a fault display, and which may correspond to a customer
complaint.
–check that the system is operating correctly and that there is no risk of a fault recurring after repairs.
This section gives the fault finding procedures for statuses and parameters and the conditions for checking them.
If a status is not behaving normally or a parameter is outside the permitted tolerance values, consult the
corresponding fault finding page.
Special notes on the conformity check for the air conditioning function:
All variables (statuses and parameters) and commands required for the air conditioning function are divided into
three sub-functions:
●The COLD LOOP sub-function groups together all the information required for producing cold air.
●The HEATING sub-function groups together all the information required for producing warm air.
●The PASSENGER COMPARTMENT VENTILATION sub-function groups together all the information relating to
ventilation and the mixing and distribution of air within the passenger compartment.
62B-21
MR-413-X44-62B000$276_eng.mif
V1
62B
CLIMATE CONTROL
Fault finding - Replacement of components
REPLACING THE CLIMATE CONTROL COMPUTER
–Note the computer configuration according to the optional equipment fitted on the vehicle (see climate control
computer configuration) or using the Shared World Information (ICM).
–Ensure that the ignition is switched off.
–After approval from the Techline, replace the computer.
–Switch on the ignition and carry out a check using the diagnostic tool.
–Configure the computer according to the vehicle specifications.
–Switch off the ignition and then back on for the configurations to register.
–Check in the Read configuration menu that the configurations have been recognised correctly.
–Check for faults and apply the corresponding fault finding procedure for any faults shown on the diagnostic tool.
–Clear any stored faults.
–Run command VP001 Enter VIN.
–Start the engine, switch on the air conditioning and ensure that it is operating correctly. WARNING
Before replacing the climate control computer, check that it is faulty (read faults, conformity of variables,
read customer complaints). Replacement of the computer must be authorised by the Techline after a fault
finding log has been completed and submitted.
Vdiag No.: 44
MR-413-X44-62B000$276_eng.mif
62B-23
MR-413-X44-62B000$322_eng.mif
V1
CLIMATE CONTROL
Fault finding - Configuration and programming
Vdiag No.: 44
62B
MIXING AND DISTRIBUTION MOTOR PROGRAMMING PROCEDURE:
There is no specific programming operation for the air mixing motor or the distribution motor.
However, the minimum and maximum limits of these motors have to be programmed. This operation is automatic
and is performed in the following cases:
–after communication using the diagnostic tool, the next time ignition is switched on,
–if a fault, declared as present when the ignition was switched off, disappears the next time the ignition is switched
on.
WARNING
It is imperative that communication is established with the diagnostic tool (to initiate programming the
next time the ignition is switched on) after any operation on the distribution and mixing motors or on the
control panel.
62B-25
MR-413-X44-62B000$414_eng.mif
V1
62B
CLIMATE CONTROL
Fault finding - Interpretation of faults
DF001
PRESENT
OR
STOREDCOMPUTER
1. DEF: Internal electronic fault
NOTESConditions for running fault finding on a present or stored fault:
Apply this fault finding procedure if the fault reappears as present or stored after the
ignition is switched of f and on again.
Switch off the ignition and wait for the immobiliser warning light (Power-latch) to come one,
–Switch on the ignition again.
–Start the engine and switch on the air conditioning.
If the fault recurs, contact the Techline.
If the fault does not reappear: leave the climate control switched on and select various ventilation and air
distribution settings to check that the system is operating correctly.
–Check that no fault is displayed.
If the fault is still present, contact the Techline.
AFTER REPAIRFollow the instructions to confirm repair.
If the computer was replaced (at the request of the Techline), reconfigure the
computer (see Configurations and programming).
Deal with any other faults.
CLIM_V44_DF001
Vdiag No.: 44
MR-413-X44-62B000$414_eng.mif
62B-26
MR-413-X44-62B000$414_eng.mif
V1
CLIMATE CONTROL
Fault finding - Interpretation of faults
Vdiag No.: 44
62B
DF007
PRESENT
OR
STOREDINTERIOR TEMPERATURE SENSOR CIRCUIT
CC.0 : Short circuit to earth
CO.1 : Short circuit or open circuit to + 12 V
NOTESConditions for running fault finding on a present or stored fault:
Apply this fault finding procedure if the fault reappears as present or stored after the
ignition is switched on and air conditioning activation is requested with the engine
running.
Special notes:
The interior temperature sensor is located at the top of the roof in the unit under the
rear view mirror.
Use the Wiring Diagram Technical Note for the New Twingo.
Check the connection and condition (possible wiring damage) of the connector of component 1872.
If the connector is faulty (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for the
repair), repair the connector, otherwise replace the wiring.
With connector A of component 419 and connector of union R301 disconnected, check the insulation and
continuity of the following connections between components R301 (dashboard/interior lights intermediate union)
and 419.
●connection 38JN
●connection 38GZ
If the connection or connections are faulty (see Technical Note 6015A, Repairing electrical wiring, Wiring:
Precautions for repair), repair the wiring, otherwise replace it.
With the connector of component 1872 disconnected, check the insulation and continuity of the following
connections between components R301 (dashboard/interior lights intermediate union) and 1872.
●connection 38JN
●connection 38GZ
If the connection or connections are faulty (see Technical Note 6015A, Repairing electrical wiring, Wiring:
Precautions for repair), repair the wiring, otherwise replace it.
Check the insulation of connections 38JN and 38GZ of component 1872.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the resistance of component 1872 between connections 38JN and 38GZ.
Replace the sensor if the resistance is not 10 kΩΩ Ω Ω
± 500 ΩΩ Ω Ω
at 25 ˚C. For more details, consult the electrical
specifications of the sensor according to the temperature (see Help).
If the fault is still present, contact the Techline.
AFTER REPAIRClear the stored faults.
Follow the instructions to confirm repair.
Deal with any other faults.
CLIM_V44_DF007
62B-27
MR-413-X44-62B000$414_eng.mif
V1
CLIMATE CONTROL
Fault finding - Interpretation of faults
Vdiag No.: 44
62B
DF010
PRESENT
OR
STOREDMIXING MOTOR CIRCUIT
CO.0 : Open circuit or short circuit to earth
CC.1 : Short circuit to + 12 V
NOTESConditions for running fault finding on a present or stored fault:
The fault is declared present when the temperature control is activated (minimum or
maximum temperature request and air conditioning control panel on).
Special notes:
Wait 1 minute after repairing the fault so that the climate control computer can control
the mixer motor. To avoid having to wait for 1 minute, switch the ignition off and then
back on again.
There is no specific programming operation for the mixing motor, however, after it has
been replaced, the motor needs to program its limits (minimum and maximum).
Use the Wiring Diagram Technical Note for the New Twingo.
Check the connection and condition of the connector of component 420.
If the connector is faulty (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for the
repair), repair the connector, otherwise replace the wiring.
With connector B of component 419 disconnected, check the insulation and continuity of the following
connections between components 419 and 420:
●connection 38LC
●connection 38LD
●connection 38LG
●connection 38LH
If the connection or connections are faulty (see Technical Note 6015A, Repairing electrical wiring, Wiring:
Precautions for repair), repair the wiring, otherwise replace it.
Connector of component 1115 disconnected,
Check the insulation and continuity of connection S between components 419 and 420.
If the connection or connections are faulty (see Technical Note 6015A, Repairing electrical wiring, Wiring:
Precautions for repair), repair the wiring, otherwise replace it.
Connector of component 419 connected and ignition on,
●Check for 12 V supply on connection S of component 420 in relation to earth NAM.
If the connection is faulty (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for the
repair), repair the wiring, otherwise replace the wiring.
If the supply is not present and if no faulty connections are detected during the continuity checks, contact your
Techline.
AFTER REPAIRClear the stored faults.
Follow the instructions to confirm repair.
If the motor has been replaced (see Configuration and programming).
Deal with any other faults.
CLIM_V44_DF010
62B-29
MR-413-X44-62B000$414_eng.mif
V1
CLIMATE CONTROL
Fault finding - Interpretation of faults
Vdiag No.: 44
62B
DF012
PRESENT
OR
STOREDDISTRIBUTION MOTOR CIRCUIT
CO.0 : Open circuit or short circuit to earth
CC.1 : Short circuit to + 12 V
NOTESConditions for running fault finding on a present or stored fault:
The fault is declared present with the air conditioning control panel on and the
distribution control activated (de-icing, ventilation, footwells, etc.).
Special notes:
Wait 1 minute after repairing the fault so that the climate control computer can control
the distribution motor. To avoid having to wait for 1 minute, switch the ignition off and
then back on again.
There is no specific programming operation for the distribution motor, however, after it
has been replaced, the motor needs to program its limits (minimum and maximum).
Use the Wiring Diagram Technical Note for the New Twingo.
Check the connection and condition of the connector of component 1115.
If the connector is faulty (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for the
repair), repair the connector, otherwise replace the wiring.
With connector of component 419 disconnected, check the insulation and continuity of the following
connections between components 419 and 1115:
●connection 38KY
●connection 38KZ
●connection 38LA
●connection 38LB
If the connection or connections are faulty (see Technical Note 6015A, Repairing electrical wiring, Wiring:
Precautions for repair), repair the wiring, otherwise replace it.
With the connector of component 420 disconnected, check the insulation and continuity of connection S
between components 419 and 1115.
If the connection or connections are faulty (see Technical Note 6015A, Repairing electrical wiring, Wiring:
Precautions for repair), repair the wiring, otherwise replace it.
Connector of component 419 connected and ignition on (air conditioning control panel on).
Check for 12 V supply on connection S of component 1115 in relation to earth NAM.
If the connection is faulty (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for the
repair), repair the wiring, otherwise replace the wiring.
If the supply is not present and if no faulty connections are detected during the continuity checks, contact your
Techline.
AFTER REPAIRClear the stored faults.
Follow the instructions to confirm repair.
If the motor has been replaced (see Configuration and programming).
Deal with any other faults.
CLIM_V44_DF012