16A-19V2 MR-413-X44-16A000$875.mif
STARTING-CHARGING
Fault finding – Tests16A
New Twingo
TEST2 Test the condition of the power fuse and the cause of its fault
NOTESCheck that the engine is not locked
With the ignition off, measure the voltage between the negative
battery terminal and the power fuse output.
Is the voltage greater than or equal to 10V?
The power fuse is sound The power fuse is faulty
With the battery disconnected, measure the resistance between
the negative battery terminal and the power fuse output.
Is the resistance
≥ 10 Ohms?
Disconnect the alternator + terminal and
then measure the resistance between the
negative battery terminal and the power
fuse output.Possible external causes:
use of a "starter charger", excessively long
use of starter (e.g.: activate the starter, gear
engaged for driving the vehicle) etc.
Is the resistance
≥ 10 Ohms?
YESNO
NOYES
CNO
A
YES
B