Page 190 of 348

17B-190V7 MR-413-X44-17B000$151.mif
PETROL INJECTION
Fault finding – Interpretation of statuses17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
ET048ACTUATOR RELAY CONTROL
STATUS
DEFINITIONACTIVE: The status indicates that the control is active.
INACTIVE: The status indicates that the control is inactive.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system operation
programming.
Conformity check: Engine stopped and ignition on, or engine running at idle speed, and engine coolant
temperature > 80˚C.
"INACTIVE"
or
ACTIVEThis relay supplies the following actuators: the injectors, the throttle valve control,
the oxygen sensor heating, the bleed solenoid valve, the fuel vapour absorber
and connection 3FB of the injection computer.
In the event of a fault, see the interpretation of fault DF084 Actuator relay control
circuit.
SIM32_V44_ET048/SIM32_V4C_ET048/SIM32_V50_ET048/SIM32_V54_ET048
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
Page 193 of 348

17B-193V7 MR-413-X44-17B000$151.mif
PETROL INJECTION
Fault finding – Interpretation of statuses17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
ET052UPSTREAM O2 SENSOR HEATING
STATUS
DEFINITIONACTIVE: This status indicates that the upstream oxygen sensor heater is active.
INACTIVE: This status indicates that the upstream oxygen sensor heater is inactive.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system operation
programming.
Conformity check: engine stopped and ignition on.
"INACTIVE"The status is inactive when the engine is off.
In the event of a fault, apply interpretation of DF082 Upstream oxygen sensor
heating circuit.
Conformity check: engine running at idle speed, engine coolant temperature > 80˚C.
"ACTIVE"The status becomes active when the engine is started and its operation increases
according to the heating temperature.
In the event of a fault, apply the interpretation of DF082.
SIM32_V44_ET052/SIM32_V4C_ET052/SIM32_V50_ET052/SIM32_V54_ET052
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
Page 194 of 348

17B-194V7 MR-413-X44-17B000$151.mif
PETROL INJECTION
Fault finding – Interpretation of statuses17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
ET053DOWNSTREAM O2 SENSOR HEATING
STATUS
DEFINITIONACTIVE: This status indicates that the downstream oxygen sensor heater is active.
INACTIVE: This status indicates that the downstream oxygen sensor heater is inactive.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system operation
programming.
Conformity check: engine stopped and ignition on.
"INACTIVE"The status is inactive when the engine is off.
In the event of a fault, apply interpretation of DF083 Downstream oxygen sensor
heating circuit.
Conformity check: engine running at idle speed, engine coolant temperature > 80˚C.
"ACTIVE"The status becomes active when the engine is started and its operation increases
according to the heating temperature.
In the event of a fault, apply the interpretation of DF083.
SIM32_V44_ET053/SIM32_V4C_ET053/SIM32_V50_ET053/SIM32_V54_ET053
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
Page 197 of 348

17B-197V7 MR-413-X44-17B000$151.mif
PETROL INJECTION
Fault finding – Interpretation of statuses17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
ET056DOUBLE RICHNESS LOOP
STATUS
DEFINITIONACTIVE: The status indicates that the double richness loop is active.
INACTIVE: The status indicates that the double richness loop is inactive.
NOTESThere must be no present or stored faults.
Special notes:
Only perform these tests if the parameters do not correspond with the system operation
programming.
Conformity check: Engine stopped and ignition on, or engine running at idle speed, and engine coolant
temperature > 80˚C.
"INACTIVE"
or
ACTIVEThis status is only inactive if one of the two oxygen sensors is in poor condition.
In the event of a fault, apply the interpretation of faults DF082 Upstream oxygen
sensor heating circuit, DF083 Downstream oxygen sensor heating circuit,
DF092 Upstream oxygen sensor circuit, DF093 Downstream oxygen
sensor circuit.
SIM32_V44_ET056/SIM32_V4C_ET056/SIM32_V50_ET056/SIM32_V54_ET056
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
Page 204 of 348
17B-204V7 MR-413-X44-17B000$151.mif
PETROL INJECTION
Fault finding – Interpretation of statuses17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
ET079AIR CONDITIONING PRESENT
STATUS
DEFINITIONYES: This status indicates that air conditioning is present on the vehicle.
NO: This status indicates that air conditioning is not present on the vehicle.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system operation
programming.
The heating and air conditioning system is present depending on the vehicle's
equipment level.
Conformity check with engine stopped and ignition on, or engine running, and engine coolant
temperature > 80˚C
"YES"
or
"NO"Depending on the vehicle equipment.
SIM32_V44_ET079/SIM32_V4C_ET079/SIM32_V50_ET079/SIM32_V54_ET079
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
Page 208 of 348

17B-208V7 MR-413-X44-17B000$152.mif
17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
ET088REQUEST TO START COMPRESSOR
STATUS
DEFINITIONACTIVE: This status indicates that the compressor is engaged.
INACTIVE: This status indicates that the compressor is not engaged.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system operation
programming.
Engine running, engine coolant temperature > 80˚C
"ACTIVE"The air conditioning request has been made by the driver when pressing one of the
air conditioning controls (Auto or AC).
Status ET088 becomes ACTIVE and the computer authorises or does not authorise
air conditioning depending on the operating conditions.
If status ET088 does not become ACTIVE when the control button is pressed, refer
to the air conditioning fault finding note (see 62A, Heating system, 62B, Climate
control or 62C, Manual air conditioning).
Note: Compressor operation is only authorised when the engine is running.
Conformity check with engine stopped and ignition on.
"INACTIVE"When the driver deactivates the air conditioning, status ET088 must become
INACTIVE.
If it does not, refer to the air conditioning fault finding note (see 62A, Heating system,
62B, Climate control or 62C, Manual air conditioning).
Note: Compressor operation is only authorised when the engine is running.
SIM32_V44_ET088/SIM32_V4C_ET088/SIM32_V50_ET088/SIM32_V54_ET088
PETROL INJECTION
Fault finding – Interpretation of statuses
AFTER REPAIRCarry out a road test followed by a check with the diagnostic tool.
Page 213 of 348

17B-213V7 MR-413-X44-17B000$152.mif
PETROL INJECTION
Fault finding – Interpretation of statuses17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
ET111SET NUMBER OF PASSENGER COMPARTMENT HEATING RESISTORS
STATUS
DEFINITIONYES: This status indicates that the number of activated passenger compartment
heating resistors is set by the injection computer.
NO: This status indicates that the number of passenger compartment heating
resistors can be freely controlled by the UCH.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system operation
programming.
Conformity check with engine stopped and ignition on, or engine running, and engine coolant
temperature > 80˚C
"YES"Depending on the requirements of the injection system (e.g. torque reduction, power
requirements), the injection computer sets the number of activated passenger
compartment heating resistors (no more or no fewer than required)
Status ET111 becomes YES when the number of activated passenger compartment
heating resistors is set by the injection computer.
"NO"Depending on the requirements of the injection system (e.g. torque reduction, power
requirements), the injection computer sets the number of activated passenger
compartment heating resistors (no more or no fewer than required)
Status ET111 becomes NO if the number of passenger compartment heating
resistors engaged can be freely controlled by the UCH.
SIM32_V44_ET111/SIM32_V4C_ET111/SIM32_V50_ET111/SIM32_V54_ET111
AFTER REPAIRCarry out a road test followed by a check with the diagnostic tool.
Page 214 of 348

17B-214V7 MR-413-X44-17B000$152.mif
PETROL INJECTION
Fault finding – Interpretation of statuses17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
ET112PASSENGER COMPARTMENT HEATING RESISTORS CUT OFF
STATUS
DEFINITIONYES: This status indicates that the passenger compartment heating resistors are
switched off at the request of the injection computer.
NO: This status indicates that the passenger compartment heating resistors can be
freely controlled by the UCH.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system operation
programming.
Conformity check with engine stopped and ignition on, or engine running, and engine coolant
temperature > 80˚C
"YES"Depending on the requirements of the injection system (e.g. torque reduction, power
requirements), the injection computer cuts off the passenger compartment heating
resistors.
Status ET112 becomes YES if the number of passenger compartment heating
resistors are cut-off by request of the injection computer.
"NO"Depending on the requirements of the injection system (e.g. torque reduction, power
requirements), the injection computer cuts off the passenger compartment heating
resistors.
Status ET112 becomes NO when the passenger compartment heating resistors
can be freely controlled by the UCH.
SIM32_V44_ET112/SIM32_V4C_ET112/SIM32_V50_ET112/SIM32_V54_ET112