17B-34V7 MR-413-X44-17B000$080.mif
PETROL INJECTION
Fault finding – Defect modes17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
Defect modes (continued)
Type 1Type 2Type 3Type 4Type 5Type 6
DF004: Turbocharging pressure
sensor circuit1.DEF
2.DEF
3.DEF1.DEF
2.DEF
3.DEF
DF011: Sensor supply voltage
no.1CC.1
CC.0CC.1
CC.0
DF012: Sensor supply voltage
no.2CC.1
CC.0CC.1
CC.0
DF038: Computer1.DEF1.DEF1.DEF1.DEF1.DEF
DF046: Battery voltage1.DEF
(
undervoltage)
1.DEF
(undervoltage)
DF054: Turbocharging solenoid
valve control circuit CO/ CC.0
CC.1/1.DEF
DF079: Motorised throttle valve
servo system2.DEF
6.DEF2.DEF
6.DEF3.DEF
4.DEF
DF089: Inlet manifold pressure
sensor circuitCO
CC.1
CC.0
DF095: Throttle potentiometer
circuit gang 1CO CC.1
CC.0
1.DEF
2.DEF
DF096: Throttle potentiometer
circuit gang 2CO
CC.1
CC.0
DF196: Pedal sensor circuit
gang 1CC.1
CC.0CC.1
CC.0
1.DEF
DF198: Pedal sensor circuit
gang 2CC.1
CC.0CC.1
CC.0
DF508: Motorised throttle controlCC.1
CC.0CC.1
CC.0
DF569: Turbocharging circuit1.DEF
2.DEF
3.DEF1.DEF
2.DEF
3.DEF1.DEF
2.DEF
3.DEF
17B-45V7 MR-413-X44-17B000$131.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
Only Vdiag 54.
DF004
PRESENT
OR
STOREDTURBOCHARGING PRESSURE SENSOR CIRCUIT
1.DEF: Voltage outside permitted range of values
2.DEF: Data inconsistency
3.DEF: EOBD
NOTESPriority when dealing with a number of faults:
Deal with fault DF012 Sensor supply voltage no. 2 as a priority if it is present
or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the ignition is switched on or after the engine has
been running at an engine speed above 600 rpm.
Special notes:
–illumination of the OBD warning light,
–Throttle valve defect mode types 5 and 6.
Use the Wiring Diagrams Technical Note for NEW TWINGO, E33, CLIO III,
or MODUS.
Check the cleanliness, condition, and fitting of the turbocharging pressure sensor (component code 1071).
If the connector is faulty and there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
If the fault is still present, manipulate the wiring harness in order to note a change in fault status (present
→
stored).
Look for possible damage to the wiring harness.
Check the condition of the engine management computer connector (component code 120).
If the connector is faulty and there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check for + 5V on connection 3LQ and for an earth on connection 3LN of the turbocharger pressure sensor,
component code 1071.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Contact the Techline if it is not correct.
SIM32_V54_DF004
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by a check with
the diagnostic tool.
17B-67V7 MR-413-X44-17B000$131.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
Vdiag 54 only
DF054
PRESENT
OR
STOREDTURBOCHARGING SOLENOID VALVE CONTROL CIRCUITCO: Open circuit
CC.0: Short circuit to earth
CC.1: Short circuit to + 12 V
1.DEF: EOBD
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after the ignition is switched on or after the engine has
been running at an engine speed above 600 rpm.
Special notes:
–OBD warning light illuminated.
–Throttle valve defect mode type 6.
Use the Wiring Diagrams Technical Note for NEW TWINGO, E33, CLIO III, or
MODUS.
Check the cleanliness, condition, and fitting of the turbocharging solenoid valve (component code 436).
If the connector is faulty and there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
If the fault is still present, manipulate the wiring harness in order to note a change in fault status (present
→
stored).
Check the condition of the engine management computer connector (component code 120).
Look for possible damage to the wiring harness.
If the connector is faulty and there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check for +12 V on connection 3AHN of the turbocharger solenoid valve, component code 436.
If +12 V is not present, check the insulation, continuity, and the absence of interference resistance on
connection:
●3AHN between components 120 and 436.
If the connection is faulty and if there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
SIM32_V54_DF054
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by a check with
the diagnostic tool.
17B-68V7 MR-413-X44-17B000$131.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF054
CONTINUED
If the fault is still present, disconnect the battery and the injection computer.
Check the insulation, continuity, and the absence of interference resistance on connection:
●3AT between components 120 and 436.
If the connection is faulty and if there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, measure the resistance of the turbocharging solenoid valve between connections 3AHN
and 3AT.
If the resistance of the turbocharger solenoid valve is not between:
●21.8 Ω < X < 24.2 Ω at 23˚C, replace the solenoid valve.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by a check with
the diagnostic tool.
17B-154V7 MR-413-X44-17B000$133.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
Only Vdiag 54
DF569
PRESENT
OR
STOREDTURBOCHARGING CIRCUIT
1.DEF: Signal outside lower limit
2.DEF: Signal outside upper limit
3.DEF: OBD
NOTESConditions for applying the fault finding procedure to stored faults
The fault is declared present with the engine running.
Special note:
Defect mode 4: speed limited to less than 66 mph (110 km/h) in 5th and 6
th and the
accelerator pedal feels spongy.
Defect mode 5: the ESP and Cruise control - Speed limiter are deactivated.
Defect mode 6: the wastegate is not controlled and opens freely.
The engine runs without turbocharging, like a naturally aspirated engine.
Use the Wiring Diagrams Technical Note for NEW TWINGO, E33, CLIO III, or
MODUS.
Check the connection of the turbocharging ducts.
Check the condition of the connector of the turbocharger pressure sensor (component code 1071), of the
wastegate solenoid valve (component code 436), and of the engine management computer (component
code 120).
If the connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Use the universal bornier to check the insulation and continuity of the following connections:
●3AHN between components 436 and 120,
●3AT between components 436 and 120,
●3LN between components 1071 and 120,
●3LP between components 1071 and 120,
●3LQ between components 1071 and 120.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
SIM32_V54_DF569
AFTER REPAIRFollow the instructions to confirm repair:
–If the fault is present, continue to deal with the fault.
–If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
17B-245V7 MR-413-X44-17B000$152.mif
PETROL INJECTION
Fault finding – Interpretation of statuses17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
ET567DEFECT MODE TYPE 4
STATUS
DEFINITIONACTIVE: This status indicates that defect mode type 4 is active.
INACTIVE: This status indicates that defect mode type 4 is inactive.
NOTESThere must be no present or stored faults.
This type groups together faults affecting the motorised throttle valve monitoring system, the pedal and the
turbocharging circuit for which there is a backup operating mode that is viable for the system.
The associated defect mode is a limitation of the throttle opening according to the engine speed. This is expressed
by limiting the speed to less than 66 mph (110 km/h) in 5
th and 6th and the accelerator pedal feels "soft".
SIM32_V44_ET567/SIM32_V4C_ET567/SIM32_V50_ET567/SIM32_V54_ET567
AFTER REPAIRCarry out a road test followed by a check with the diagnostic tool.
17B-246V7 MR-413-X44-17B000$152.mif
PETROL INJECTION
Fault finding – Interpretation of statuses17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
ET568TYPE 5 DEFECT MODE
STATUS
DEFINITIONACTIVE: This status indicates that defect mode type 5 is active.
INACTIVE: This status indicates that defect mode type 5 is inactive.
NOTESThere must be no present or stored faults.
This type groups together faults affecting the pressure, the throttle valve control by the torque structure and the
turbocharging pressure.
Its effect is to go into pedal feedback mode instead of the permanent torque structure. The ESP and cruise control/
speed limiter systems are deactivated. The automatic or sequential gearbox goes into safe mode. The engine
management no longer accepts requests from the gearbox, and sends torque values by default to the multiplex
network.
SIM32_V44_ET568/SIM32_V4C_ET568/SIM32_V50_ET568/SIM32_V54_ET568
AFTER REPAIRCarry out a road test followed by a check with the diagnostic tool.
17B-247V7 MR-413-X44-17B000$152.mif
PETROL INJECTION
Fault finding – Interpretation of statuses17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
ET569DEFECT MODE TYPE
6
STATUS
DEFINITIONACTIVE: This status indicates that defect mode type 6 is active.
INACTIVE: This status indicates that defect mode type 6 is inactive.
NOTESThere must be no present or stored faults.
This type groups the faults affecting the wastegate control in turbocharged vehicles.
Defect mode enables the engine to operate as a naturally aspirated engine.
The wastegate is no longer controlled and opens freely. The vehicle operates without turbocharging: loss of
turbocharger effectiveness (brisk engine performance, acceleration, recovery, etc.); operation as a naturally
aspirated engine.
Entry into type 1 to 5 defect mode always leads to the application of type 6 in turbocharged versions.
SIM32_V44_ET569/SIM32_V4C_ET569/SIM32_V50_ET569/SIM32_V54_ET569
AFTER REPAIRCarry out a road test followed by a check with the diagnostic tool.