83A
INSTRUMENT PANEL
Fault finding - Command summary table
Tool command Diagnostic tool title
VP020Update fuel level display
RZ001Fault memory
Vdiag No.: 04, 08
MR-413-X44-83A000$784.mif
Page 46 of 66
83A-46
MR-413-X44-83A000$840.mif
V5
83A
INSTRUMENT PANEL
Fault finding - Interpretation of commands
VP020 UPDATE FUEL LEVEL DISPLAY
This command is used for updating the fuel level display.
Once the command has been run, PR040 CURRENT FUEL LEVEL and PR041 FILTERED FUEL LEVEL
must produce equivalent values.
In the event of a fault, refer to the interpretation of fault DF007 Fuel sender circuit.
TDB_V04_VP020 / TDB_V08_VP020
Vdiag No.: 04, 08
MR-413-X44-83A000$840.mif
Page 48 of 66
83A-48
MR-413-X44-83A000$896.mif
V5
83A
INSTRUMENT PANEL
Fault finding - Customer complaints
NOTESOnly refer to the customer complaints after a complete check using the diagnostic
tool
Carry out fault finding on the multiplex network.
Carry out fault finding on the instrument panel.
NO COMMUNICATION WITH THE INSTRUMENT PANEL
THE INSTRUMENT PANEL DOES NOT LIGHT UPALP 1
THE FUEL LEVEL INDICATOR DOES NOT DISPLAY FULL
ALP 2
ADDITION OF FUEL NOT REGISTERED (NOT FULL)
ALP 3
DISPLAY JAMMED WHEN DRIVING (NOT MECHANICAL)
ALP 4
FAULT WITH NO WARNING GIVEN BY WARNING LIGHT (NO ADDITION OF FUEL
SINCE THE FAULT)ALP 5
FAULT WITH NO WARNING GIVEN BY WARNING LIGHT (ADDITION OF FUEL SINCE
THE FAULT)ALP 6
FAULT WITH DELAYED WARNING
ALP 7
Vdiag No.: 04, 08
MR-413-X44-83A000$896.mif
Page 52 of 66

83A-52
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
V5 MR-413-X44-83A000$952.mif
INSTRUMENT PANEL
Fault finding - Fault finding chart Vdiag No.: 04, 0883A
Vdiag No.: 04 08
ALP 2 The fuel level indicator does not display full
NOTESThe fuel tank must be filled with the ignition switched off (advise the customer to remove
the key).
Ideally the customer must fill the tank with at least 15 litres.
See Wiring diagram Technical Note, New Twingo.
Ask the customer if the tank is filled up under the
following conditions:
–the customer filled the tank up to the 3
rd cut-out
–the customer has changed filling station
–the customer filled the tank in a flat-level station (not
on a slope).
Did the customer fill the tank while observing all of
these conditions?Ask the customer to return just after
having filled the tank under the conditions
mentioned above.
NO
YES
A
TDB_V04_ALP2/TDB_V08_ALP2
Page 53 of 66
83A-53
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
V5 MR-413-X44-83A000$952.mif
INSTRUMENT PANEL
Fault finding - Fault finding chart Vdiag No.: 04, 0883A
Vdiag No.: 04 08
ALP 2
CONTINUED 1
With the ignition off, disconnect the fuel sender
connector, component code 833 and then check
the resistance using a multimeter.
The value should be: 38 ΩΩ Ω Ω
.
Is the value measured less than 38 ΩΩ Ω Ω
?Replace the fuel sender, component code
833 (see MR 411, Mechanical, 19C, Fuel
tank, Sender: Removal - Refitting).
If the fault is still present, contact Techline.
Compare the value measured to the value supplied
by the CLIP tool.
Is the value measured and the value provided
by the CLIP tool the same as or approximately
± 5 ΩΩ Ω Ω
?
A
YES
NO
YES
NOC
YES
B
Page 56 of 66
83A-56
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
V5 MR-413-X44-83A000$952.mif
INSTRUMENT PANEL
Fault finding - Fault finding chart Vdiag No.: 04, 0883A
Vdiag No.: 04 08
ALP 2
CONTINUED 4
Use the CLIP tool to check that the needle or
digital display type indicators are working correctly
using parameter VP020 Fuel level display
update.
Is the result of the check correct?Contact the Techline.
If the needle or display indicator test is incorrect,
replace the instrument panel, component code
247 (see MR 411, Mechanical, 83A, Instrument
panel, Instrument panel: Removal - Refitting).
Is the fault still present?The problem disappears.
Contact the Techline.
B
YES
YES
NO
NO
YES
Page 57 of 66
83A-57
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
V5 MR-413-X44-83A000$952.mif
INSTRUMENT PANEL
Fault finding - Fault finding chart Vdiag No.: 04, 0883A
Vdiag No.: 04 08
ALP 3 Addition of fuel not registered (not full)
NOTESOnly consult this customer complaint after a full check with the diagnostic tool.
Consult the interpretation of ALP2 The fuel level indicator does not display full.
TDB_V04_ALP3/TDB_V08_ALP3
Page 58 of 66

83A-58
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
V5 MR-413-X44-83A000$952.mif
INSTRUMENT PANEL
Fault finding - Fault finding chart Vdiag No.: 04, 0883A
Vdiag No.: 04 08
ALP 4 Display jammed when driving (not mechanical)
NOTESOnly consult this customer complaint after a full check with the diagnostic tool.
For economical driving, the blocks on the display may remain illuminated or the needle
may remain jammed up to 120 miles (200 kms).
Check that there is no mechanical jamming.
If the fault is on the block at the top of the display or the needle is jammed at full:
check that the customer has travelled a sufficient amount of Km (miles) for the block at the top of the display to
go out or for the needle to move from the full section.
Check that the customer has not exceeded 3 filler cut-outs when filling the tank with fuel.
If the fault is still present or if the needle or the display is jammed in any position other than full, contact the Techline.
TDB_V04_ALP4/TDB_V08_ALP4