Page 2420 of 4171
AIR CONDITIONER CONTROLHAC-107
< ECU DIAGNOSIS > [AUTOMATIC AIR CONDITIONER]
C
D
E
F
G H
J
K L
M A
B
HAC
N
O P
ABIIA0062GB
Revision: December 20092009 QX56
Page 2421 of 4171
HAC-108
< ECU DIAGNOSIS >[AUTOMATIC AIR CONDITIONER]
AIR CONDITIONER CONTROL
AAIIA0058GB
Revision: December 20092009 QX56
Page 2422 of 4171
![INFINITI QX56 2009 Factory Service Manual AIR CONDITIONER CONTROLHAC-109
< SYMPTOM DIAGNOSIS > [AUTOMATIC AIR CONDITIONER]
C
D
E
F
G H
J
K L
M A
B
HAC
N
O P
SYMPTOM DIAGNOSIS
AIR CONDITIONER CONTROL
Symptom Matrix ChartINFOID:0000000003775390 INFINITI QX56 2009 Factory Service Manual AIR CONDITIONER CONTROLHAC-109
< SYMPTOM DIAGNOSIS > [AUTOMATIC AIR CONDITIONER]
C
D
E
F
G H
J
K L
M A
B
HAC
N
O P
SYMPTOM DIAGNOSIS
AIR CONDITIONER CONTROL
Symptom Matrix ChartINFOID:0000000003775390](/manual-img/42/57031/w960_57031-2421.png)
AIR CONDITIONER CONTROLHAC-109
< SYMPTOM DIAGNOSIS > [AUTOMATIC AIR CONDITIONER]
C
D
E
F
G H
J
K L
M A
B
HAC
N
O P
SYMPTOM DIAGNOSIS
AIR CONDITIONER CONTROL
Symptom Matrix ChartINFOID:0000000003775390
SYMPTOM TABLE
Symptom Reference Page
A/C system does not come on. Go to Trouble Diagnosis Procedure for A/C System. HAC-89
A/C system display is malfunctioning. Go to Navigation System. AV- 6 9
A/C system cannot be controlled.Go to Self-diagnosis Function. HAC-23
Air outlet does not change.
Go to Trouble Diagnosis Procedure for Mode Door Motor. HAC-26
Mode door motor is malfunctioning.
Discharge air temperature does not change.
Go to Trouble Diagnosis Procedure for Air Mix Door Motor. HAC-32
Air mix door motor is malfunctioning.
Intake door does not change.
Go to Trouble Diagnosis Procedure for Intake Door Motor. HAC-42
Intake door motor is malfunctioning.
Defroster door motor is malfunctioning. Go to Trouble Diagnosis Procedure for Defroster Door Motor. HAC-46
Front blower motor operation is malfunction-
ing.Go to Trouble Diagnosis Procedure for Front Blower Motor.
HAC-51
Rear blower motor operation is malfunction-
ing.Go to Trouble Diagnosis Procedure for Rear Blower Motor.
HAC-57
Rear discharge air temperature and/or air
outlet does not change.Go to Trouble Diagnosis Procedure for Rear Air Control circuit.
HAC-62
Magnet clutch does not engage.Go to Trouble Diagnosis Procedure for Magnet Clutch. HAC-72
Insufficient coolingGo to Trouble Diagnosis Procedure for Insufficient Cooling. HAC-110
Insufficient heatingGo to Trouble Diagnosis Procedure for Insufficient Heating. HAC-118
NoiseGo to Trouble Diagnosis Procedure for Noise. HAC-120
Self-diagnosis cannot be performed. Go to Trouble Diagnosis Procedure for Self-diagnosis. HAC-89
Memory function does not operate.Go to Trouble Diagnosis Procedure for Memory Function. HAC-122
Revision: December 20092009 QX56
Page 2423 of 4171
![INFINITI QX56 2009 Factory Service Manual HAC-110
< SYMPTOM DIAGNOSIS >[AUTOMATIC AIR CONDITIONER]
INSUFFICIENT COOLING
INSUFFICIENT COOLING
Component Function CheckINFOID:0000000003775391
SYMPTOM: Insufficient cooling
INSPECTION FLOW
1.CONFI INFINITI QX56 2009 Factory Service Manual HAC-110
< SYMPTOM DIAGNOSIS >[AUTOMATIC AIR CONDITIONER]
INSUFFICIENT COOLING
INSUFFICIENT COOLING
Component Function CheckINFOID:0000000003775391
SYMPTOM: Insufficient cooling
INSPECTION FLOW
1.CONFI](/manual-img/42/57031/w960_57031-2422.png)
HAC-110
< SYMPTOM DIAGNOSIS >[AUTOMATIC AIR CONDITIONER]
INSUFFICIENT COOLING
INSUFFICIENT COOLING
Component Function CheckINFOID:0000000003775391
SYMPTOM: Insufficient cooling
INSPECTION FLOW
1.CONFIRM SYMPTOM BY PERFORMING OPER
ATIONAL CHECK - TEMPERATURE DECREASE
1. Press the AUTO switch.
2. Turn temperature control dial (driver) counterclockwise until 16 °C (60 °F) is displayed.
3. Check for cold air at discharge air outlets.
Can the symptom be duplicated?
YES >> GO TO 3.
NO >> GO TO 2.
2.CHECK FOR ANY SYMPTOMS
Perform a complete operational check for any symptoms. Refer to HAC-4, "
Operational Check (Front)".
Does another symptom exist?
YES >> Refer to HAC-109, "SymptomMatrixChart".
NO >> System OK.
3.CHECK FOR SERVICE BULLETINS
Check for any service bulletins.
>> GO TO 4.
4.PERFORM SELF-DIAGNOSIS
Perform self-diagnosis Refer to HAC-23, "
A/C Auto Amp. Self-Diagnosis".
Is the inspection result normal?
YES >> GO TO 5.
NO >> Refer to HAC-24, "
A/C System Self-Diagnosis Code Chart".
5.CHECK DRIVE BELTS
Check compressor belt tension. Refer to EM-13, "
Checking Drive Belts".
Is the inspection result normal?
OK >> GO TO 6.
NG >> Adjust or replace compressor belt. Refer to EM-13, "
Removal and Installation".
6.CHECK AIR MIX DOOR OPERATION
Check and verify air mix door mechanism for smooth operation. Refer to HAC-32, "
Air Mix Door Motor Compo-
nent Function Check".
Does air mix door operate correctly?
YES >> GO TO 7.
NO >> Check air mix door motor circuit. Refer to HAC-33, "
Air Mix Door Motor (Driver) Diagnosis Proce-
dure" or HAC-36, "Air Mix Door Motor (Passenger) Diagnosis Procedure".
7.CHECK COOLING FAN MOTOR OPERATION
Check and verify cooling fan motor for smooth operation. Refer to EC-388, "
Component Inspection".
Does cooling fan motor operate correctly?
YES >> GO TO 8.
NO >> Check cooling fan motor. Refer to EC-388, "
Diagnosis Procedure".
8.CHECK WATER VALVE OPERATION
Check and verify water valve for smooth operation. Refer to HAC-77, "
Description".
Does water valve operate correctly?
YES >> GO TO 9.
Revision: December 20092009 QX56
Page 2424 of 4171
![INFINITI QX56 2009 Factory Service Manual INSUFFICIENT COOLINGHAC-111
< SYMPTOM DIAGNOSIS > [AUTOMATIC AIR CONDITIONER]
C
D
E
F
G H
J
K L
M A
B
HAC
N
O P
NO >> Check water valve circuit. Refer to HAC-77, "Water Valve Diagnosis Procedure".
9. INFINITI QX56 2009 Factory Service Manual INSUFFICIENT COOLINGHAC-111
< SYMPTOM DIAGNOSIS > [AUTOMATIC AIR CONDITIONER]
C
D
E
F
G H
J
K L
M A
B
HAC
N
O P
NO >> Check water valve circuit. Refer to HAC-77, "Water Valve Diagnosis Procedure".
9.](/manual-img/42/57031/w960_57031-2423.png)
INSUFFICIENT COOLINGHAC-111
< SYMPTOM DIAGNOSIS > [AUTOMATIC AIR CONDITIONER]
C
D
E
F
G H
J
K L
M A
B
HAC
N
O P
NO >> Check water valve circuit. Refer to HAC-77, "Water Valve Diagnosis Procedure".
9.CHECK RECOVERY/RECYCLING EQUIPMENT BEFORE USAGE
Check recovery/recycling equipment befor e connecting to vehicle. Verify there is no pressure in the recovery/
recycling equipment by checking the gauges. If pressure exists, recover refrigerant from equipment lines.
>> GO TO 10.
10.CHECK REFRIGERANT PURITY
1. Connect recovery/recycling equipment to vehicle.
2. Confirm refrigerant purity in supply tank us ing recovery/recycling and refrigerant identifier.
Is the inspection result normal?
YES >> GO TO 11.
NO >> Check contaminated refrigerant. Refer to HAC-123, "
Working with HFC-134a (R-134a)".
11 .CHECK FOR EVAPORATOR FREEZE UP
Start engine and run A/C. Check for evaporator freeze up.
Does evaporator freeze up?
YES >> Perform performance test diagnoses. Refer to HAC-111, "Diagnostic Work Flow".
NO >> GO TO 12.
12.CHECK REFRIGERANT PRESSURE
Check refrigerant pressure with manifold gauge connected. Refer to HAC-113, "
Performance Chart".
Is the inspection result normal?
YES >> Perform performance test diagnoses. Refer to HAC-111, "Diagnostic Work Flow".
NO >> GO TO 13.
13.CHECK AIR DUCTS
Check ducts for air leaks.
Is the inspection result normal?
YES >> System OK.
NO >> Repair air leaks.
Diagnostic Work FlowINFOID:0000000003775392
Revision: December 20092009 QX56
Page 2425 of 4171
HAC-112
< SYMPTOM DIAGNOSIS >[AUTOMATIC AIR CONDITIONER]
INSUFFICIENT COOLING
*1
HA-24, "Checking System for Leaks
Using the Fluorescent Dye Leak De-
tector"
*2HA-31, "Removal and Installation for
Compressor"
*3HAC-113, "Performance Chart"
*4HAC-114, "Trouble Diagnoses for Ab-
normal Pressure"
*5HAC-32, "Air Mix Door Motor Compo-
nent Function Check"
AWIIA0999GB
Revision: December 20092009 QX56
Page 2426 of 4171
INSUFFICIENT COOLINGHAC-113
< SYMPTOM DIAGNOSIS > [AUTOMATIC AIR CONDITIONER]
C
D
E
F
G H
J
K L
M A
B
HAC
N
O P
Performance ChartINFOID:0000000003775393
Test Condition
Testing must be performed as follows:
*1 VTL-12, "Removal and Installation"*2HAC-51, "Front Blower Motor Com-
ponent Function Check"
*3 HA-32, "Removal and Installation for
Compressor Clutch"
*4EM-13, "Checking Drive Belts"*5HA-31, "Removal and Installation for
Compressor"
AWIIA1000GB
Revision: December 20092009 QX56
Page 2427 of 4171
![INFINITI QX56 2009 Factory Service Manual HAC-114
< SYMPTOM DIAGNOSIS >[AUTOMATIC AIR CONDITIONER]
INSUFFICIENT COOLING
TEST READING
Recirculating-to-discharge Air Temperature Table
Ambient Air Temperature-to-operating Pressure Table
Trouble INFINITI QX56 2009 Factory Service Manual HAC-114
< SYMPTOM DIAGNOSIS >[AUTOMATIC AIR CONDITIONER]
INSUFFICIENT COOLING
TEST READING
Recirculating-to-discharge Air Temperature Table
Ambient Air Temperature-to-operating Pressure Table
Trouble](/manual-img/42/57031/w960_57031-2426.png)
HAC-114
< SYMPTOM DIAGNOSIS >[AUTOMATIC AIR CONDITIONER]
INSUFFICIENT COOLING
TEST READING
Recirculating-to-discharge Air Temperature Table
Ambient Air Temperature-to-operating Pressure Table
Trouble Diagnoses fo
r Abnormal PressureINFOID:0000000003775395
Whenever system′s high and/or low side pressure is unusual, diagnose using a manifold gauge. The marker
above the gauge scale in the following tables indicates the standard (usual) pressure range. Since the stan-
Vehicle location Indoors or in the shade (in a well-ventilated place)
Doors Closed
Door window Open
Hood Open
TEMP. Max. COLD
Mode switch (Ventilation) set
Recirculation (REC) switch (Recirculation) set
Blower speed Max. speed set
Engine speed Idle speed
Operate the air conditioning system for 10 minutes before taking measurements.
Inside air (Recirculating air) at blower assembly inlet Discharge air temperature at center ventilator
°C ( °F)
Relative humidity
% Air temperature
°C ( °F)
50 - 60 20 (68)
9.9 - 13.9 (50 - 57)
25 (77) 14.6 - 18.6 (58 - 65)
30 (86) 16.8 - 21.8 (62 - 71)
35 (95) 21.1 - 27.1 (70 - 81)
40 (104) 25.3 - 31.5 (78 - 89)
60 - 70 20 (68)
11.4 - 15.2 (53 - 59)
25 (77) 15.5 - 20.0 (60 - 68)
30 (86) 19.9 - 25.0 (68 - 77)
35 (95) 24.5 - 29.6 (76 - 85)
40 (104) 28.7 - 34.9 (84 - 95)
Ambient air High-pressure (Discharge side)
kPa (kg/cm
2 , psi) Low-pressure (Suction side)
kPa (kg/cm2 , psi)
Relative humidity
% Air temperature
°C ( °F)
50 - 70 20 (68)
1020 - 1250
(10.4 - 12.7, 147.9 - 181.3) 160 - 190
(1.63 - 1.94, 23.2 - 27.6)
25 (77) 1236 - 1510
(12.6 - 15.4, 179.2 - 219) 206 - 245
(2.1 - 2.5, 29.9 - 35.6)
30 (86) 1569 - 1,922
(16.0 - 19.6, 227.6 - 278.8) 265 - 324
(2.7 - 3.3, 38.4 - 46.9)
35 (95) 1,697 - 2079
(17.3 - 21.2, 246.1 - 301.5) 304 - 363
(3.1 - 3.7, 44.1 - 52.6)
40 (104) 1971 - 2403
(20.1 - 24.5, 285.9 - 348.5) 373 - 451
(3.8 - 4.6, 54.0 - 65.4)
Revision: December 20092009 QX56