DLK-106
< COMPONENT DIAGNOSIS >[WITH INTELLIGENT KEY SYSTEM]
INTELLIGENT KEY BATTERY AND FUNCTION
INTELLIGENT KEY BATTERY AND FUNCTION
DescriptionINFOID:0000000003775777
The following functions are available when having and carrying electronic ID.
• Door lock/unlock
• Back door open
Remote control entry function and panic alarm functi
on are available when operating the remote buttons.
Component Function CheckINFOID:0000000003775778
1.CHECK FUNCTION
With CONSULT-III
Check remote keyless entry receiver "RKE OPE COUN1" in DATA MONITOR mode with CONSULT-III.
Is the inspection result normal?
YES >> Intelligent Key is OK.
NO >> Refer to DLK-106, "
Diagnosis Procedure".
Diagnosis ProcedureINFOID:0000000003775779
1.CHECK INTELLIGENT KEY FUNCTION
Check keyfob function using Remote Keyless Entry Tester J-43241.
Does the test pass?
YES >> Intelligent Key is OK.
NO >> GO TO 2
2. CHECK INTELLIGENT KEY COMPONENTS
1. Release the lock knob at the back of the Intelligent Key and remove the mechanical key.
2. Insert a flat-blade screwdriver (A) wrapped with a cloth into the slit of the corner and twist it to separate the upper part from the
lower part.
CAUTION:
• Do not touch the circuit board or battery terminal.
• The keyfob is water-resistant. However, if it does get wet,
immediately wipe it dry.
3. Remove the Intelligent Key battery.
CAUTION:
• Keep dirt, grease, and other fo reign materials off the elec-
trode contact area.
4. Visually inspect keyfob internal components.
Is the inspection result normal?
YES >> GO TO 3
NO >> Repair or replace malfunctioning parts.
3.CHECK INTELLIGENT KEY BATTERY
Monitor item Condition
RKE OPE COUN1 Check that the numerical value is changing while operating the Intelligent Key.
LEL946A
PIIB6221E
Revision: December 20092009 QX56
AUTOMATIC BACK DOOR SELF-DIAGNOSIS PROCEDUREDLK-123
< COMPONENT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G H
I
J
L
M A
B
DLK
N
O P
AUTOMATIC BACK DOOR SELF-DIAGNOSIS PROCEDURE
Self-Diagnosis ProcedureINFOID:0000000003775801
INPUT SIGNAL CHECK MODE
Input signal check mode allows testing of swit ch input signal to the back door control unit.
To activate input signal check mode on the automatic sliding door, perform the following steps:
1. Turn ignition switch OFF.
2. Turn back door close switch to CANCEL (system cancelled).
3. Place A/T shift selector in P position.
4. Using the inside emergency release lever, open the back door.
5. Have an assistant press and hold the back door handle switch.
6. While the assistant continues to hold the back door handle switch, turn ignition switch ON (DO NOT start
engine).
7. After approximately 5 seconds, the back door warning chime will sound for 0.5 seconds.
8. Release the back door handle switch.
9. Within 8 seconds of the back door warning chime sounding, press and hold the power liftgate switch.
10. After approximately 5 seconds, the back door warning chime will sound for 1 second.
11. Release the power liftgate switch.
12. The input signal check mode is now initialized.
The input signal check mode can test the following inputs. The back door warning chime will sound for approx-
imately 0.5 second each time a switch signal input oc curs. Use this test when one of these inputs is not
responding during normal automatic back door operation.
*Back door warning chime should sound as soon as vehicle moves.
Turn ignition switch OFF to end input signal check mode.
OPERATING CHECK MODE
Operating check mode allows self-diagnos is of the automatic back door system.
To activate operating check mode on the automatic back door, perform the following steps:
1. Turn ignition switch OFF.
2. Turn back door close switch to CANCEL (system cancelled).
3. Place A/T shift selector in P position.
4. Using the inside emergency release lever, open the back door.
5. Have an assistant press and hold the back door handle switch.
6. While the assistant continues to hold the back door handle switch, turn ignition switch ON (DO NOT start engine).
7. After approximately 5 seconds, the back door warning chime will sound for 0.5 second.
8. Release the back door handle switch.
Switch signal OperationRefer to
Power liftgate switch OFF → ONDLK-129
Back door close switch (CLOSE) OFF → ON DLK-131
Back door close switch (CANCEL) OFF → ON DLK-132
Back door handle switch OFF → ON DLK-138
A/T shift selector (park position switch) P position → other than P position DLK-101
Vehicle speed* Vehicle speedTM-49
Remote keyless entry signal Keyfob switch OFF → ON DLK-103
Door lock/unlock signal LOCK → UNLOCK DLK-74
Pinch strip LH signal OFF → ON DLK-133
Pinch strip RH signal OFF → ON DLK-133
Revision: December 20092009 QX56
GLASS HATCH SWITCHDLK-127
< COMPONENT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G H
I
J
L
M A
B
DLK
N
O P
GLASS HATCH SWITCH
Diagnosis ProcedureINFOID:0000000004190670
NOTE:
Repair any front door lock actuator RH malf unction before proceeding with this diagnosis.
1.CHECK GLASS HATCH SWITCH
1. Turn ignition switch OFF.
2. Insure front door lock actuator RH is in the unlock position.
3. Check continuity between glass hatch switch terminal 2 and ground.
Is the inspection result normal?
YES >> GO TO 2.
NO >> GO TO 3.
2.CHECK HARNESS CONTINUITY
1. Disconnect glass hatch switch.
2. Disconnect BCM.
3. Check continuity between BCM connector M18 (A) terminal 30 and glass hatch switch connector D706 (B) terminal 2.
4. Check continuity between BCM connector M18 (A) terminal 30 and ground.
Is the inspection result normal?
YES >> Glass hatch switch circuit is OK.
NO >> Repair or replace harness.
3.CHECK GLASS HATCH SWITCH
1. Disconnect glass hatch switch.
2. Check continuity between glass hatch switch harness connector D706 terminal 1 and ground.
Is the inspection result normal?
YES >> Replace glass hatch switch.
NO >> GO TO 4.
4.CHECK HARNESS CONTINUITY
1. Disconnect front door lock actuator RH.
Connec- tor Te r m i n a l s
ConditionContinuity
(+) (–)
D706 2 Ground With the glass hatch switch
pressed
Ye s
With the glass hatch switch
released No
LIIA2399E
30 - 2
: Continuity should exist.
30 - Ground : Continuity should not exist.
LIIA2400E
1 - Ground: Continuity should exist.
LIIA2401E
Revision: December 20092009 QX56
DLK-128
< COMPONENT DIAGNOSIS >[WITH INTELLIGENT KEY SYSTEM]
GLASS HATCH SWITCH
2. Check continuity between glass hatch switch connector D706
(A) terminal 1 and front door lock actuator RH connector D114
(B) terminal 4
Is the inspection result normal?
YES >> GO TO 5.
NO >> Repair or replace harness.
5.CHECK FRONT DOOR LOCK ACTUATOR RH GROUND CIRCUIT
Check continuity between front door lock actuator RH connector
D114 terminal 5 and ground
Is the inspection result normal?
YES >> Replace front door lock actuator RH. Refer to DLK-238,
"Removal and Installation".
NO >> Repair or replace harness. 1 - 4 : Continuity should exist.
LIIA2402E
5 - Ground
: Continuity should exist.
LIIA2403E
Revision: December 20092009 QX56
DLK-140
< COMPONENT DIAGNOSIS >[WITH INTELLIGENT KEY SYSTEM]
INTELLIGENT KEY UNIT POWER BACK DOOR INPUT SIGNAL
INTELLIGENT KEY UNIT POWER BACK DOOR INPUT SIGNAL
DescriptionINFOID:0000000003775813
Carrying the Intelligent Key, enables the driver to open the liftgate using the back door handle even when the
vehicle is locked. When lifting the handle, the back door
handle switch sends this signal to the Intelligent Key
unit which treats it as a request switch signal. When t he Intelligent Key unit, using the rear bumper antenna,
validates the presence of the Intelligent Key, it s ends an open signal to the back door control unit regardless
whether the vehicle is locked.
Rear bumper antenna is mounted on the rear bumper and is used to allow the back door handle opening of
the locked back door when the Intelligent Key is present.
Diagnosis ProcedureINFOID:0000000003775814
1.BACK DOOR HANDLE SWITCH SIGNAL INSPECTION
With all doors unlocked, check the back door handle operation by lifting the handle.
Did the back door respond correctly by opening?
YES >> GO TO 2
NO >> Refer to DLK-138, "
Diagnosis Procedure".
2.KEYFOB SIGNAL INSPECTION
Check keyfob operation using lock and unlock buttons.
Did the keyfob respond correctly?
YES >> GO TO 3
NO >> Refer to DLK-106, "
Diagnosis Procedure".
3.INTELLIGENT KEY UNIT SIGNAL INSPECTION
NOTE:
Since the diode is a uni-directional component, pay close attention to the polarity of the ohmmeter
being used as the presence of a diode in the circuit will affect the result.
1. Turn ignition switch OFF.
2. Disconnect Intelligent Key unit, back door handle switch and back door control unit connectors.
3. Check continuity between Intelligent Key unit connector (A) M70 terminal 29 and back door handle switch connector (B) D706
terminal 3.
4. Check continuity between Intelligent Key unit connector (A) M70 terminal 29 and ground.
Is the inspection result normal?
YES >> Replace the Intelligent Key unit.
NO >> Repair or replace the harness or the diode as necessary. 29 (+) - 3 (-) : Continuity should exist.
29 (+) - Ground (-) : Conti
nuity should not exist.
ALKIA1793ZZ
Revision: December 20092009 QX56
INTELLIGENT KEY UNIT POWER BACK DOOR OUTPUT SIGNAL
DLK-141
< COMPONENT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G H
I
J
L
M A
B
DLK
N
O P
INTELLIGENT KEY UNIT POWE R BACK DOOR OUTPUT SIGNAL
DescriptionINFOID:0000000003775815
The keyfob of the Intelligent Key unit is capable of opening and closing the power back door. The driver can
open or close the liftgate by pressing the liftgate button regardless whether the vehicle is locked provided the
keyfob is within operating range.
Diagnosis ProcedureINFOID:0000000003775816
1.POWER LIFTGATE SWITCH FUNCTION INSPECTION
Check power liftgate switch using switch operation.
Did the back door respond correctly?
YES >> GO TO 2
NO >> Refer to DLK-125, "
Diagnosis Procedure".
2.KEYFOB SIGNAL INSPECTION
Check keyfob operation using lock and unlock buttons.
Did the keyfob operate correctly?
YES >> GO TO 3
NO >> Refer to DLK-106, "
Diagnosis Procedure".
3.INTELLIGENT KEY UNIT SIGNAL INSPECTION
1. Turn ignition switch OFF.
2. Disconnect Intelligent Key unit, back door cont rol unit and power liftgate switch connectors.
3. Check continuity between Intelligent Key unit connector (A) M70
terminal 23 and back door control unit connector (B) B55 termi-
nal 23.
4. Check continuity between Intelligent Key unit connector (A) M70 terminal 23 and ground.
Is the inspection result normal?
YES >> Replace Intelligent Key unit.
NO >> Repair or replace the harness as necessary. 23 - 23 : Continuity should exist.
23 - Ground : Continuity should not exist.
ALKIA0680ZZ
Revision: December 20092009 QX56
HOMELINK UNIVERSAL TRANSCEIVERDLK-143
< COMPONENT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G H
I
J
L
M A
B
DLK
N
O P
DescriptionINFOID:0000000003775818
Homelink universal transceiver can store and transmit a maximum of 3 radio signals.
Allows operation of garage doors, gates, home and office lighting, entry door locks and security system, etc.
Homelink universal transceiver power supply uses vehicle battery, which enables it to maintain every program
in case battery is discharged or removed.
ABKIA0056GB
Revision: December 20092009 QX56
DLK-144
< COMPONENT DIAGNOSIS >[WITH INTELLIGENT KEY SYSTEM]
HOMELINK UNIVERSAL TRANSCEIVER
Component Function Check
INFOID:0000000003775819
1.CHECK FUNCTION
Check that system receiver (garage door opener, et c.) operates with original hand-held transmitter.
Is the inspection result normal?
YES >> GO TO 2
NO >> Receiver or hand-held transmitter is malfunctioning.
2.CHECK ILLUMINATION
1. Turn ignition switch “OFF”.
2. Press each of the transmitter buttons and watch for the red light
to illuminate with each button.
Is the inspection result normal?
YES >> GO TO 3
NO >> Refer to DLK-144, "
Diagnosis Procedure".
3.CHECK TRANSMITTER
Check transmitter with Tool*.
*:For details, refer to Technical Service Bulletin.
Is the inspection result normal?
YES >> Receiver or hand-held transmitter malfunction, not vehicle related.
NO >> Replace auto anti-dazzling inside mirror (homelink universal transceiver).
Diagnosis ProcedureINFOID:0000000003775820
1.CHECK POWER SUPPLY
1. Disconnect auto anti-dazzling inside mirror (homelink universal transceiver) connector.
2. Check voltage between auto anti-dazzling inside mirror (homelink universal transceiver) harness connector and ground.
Is the inspection result normal?
YES >> GO TO 2
NO >> Check the following. • 10A fuse [No. 19 located in the fuse block (J/B)]
• Harness for open or short between fuse and auto anti-dazzling inside mirror (homelink universaltransceiver).
PIIA4815E
ALKIA0659ZZ
Auto anti-dazzling inside mirror
(Homelink universal transceiver) connector Terminal Condition
Voltage (V)
(Approx.)
R7 10Ground Ignition switch position: LOCK Battery voltage
Revision: December 20092009 QX56