2008 SUZUKI SWIFT Lock control

[x] Cancel search: Lock control

Page 912 of 1496

SUZUKI SWIFT 2008 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine 6C-30 Power Assisted Steering System: 
DTC C1141 / C1142 / C1143 / C1145: P/S Motor Circuit FailureS7RS0B6304019
DTC C1141: P/S Motor Circuit V

Page 914 of 1496

SUZUKI SWIFT 2008 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine 6C-32 Power Assisted Steering System: 
DTC C1153: P/S Control Module Power Supply Circuit Voltage LowS7RS0B6304020
Wiring Diagram
DTC Detecting

Page 916 of 1496

SUZUKI SWIFT 2008 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine 6C-34 Power Assisted Steering System: 
P/S Control Module Power Supply and Ground Circuit CheckS7RS0B6304022
Wiring Diagram
1
[A ]
123
4 5 67
8

Page 918 of 1496

SUZUKI SWIFT 2008 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine 6C-36 Power Assisted Steering System: 
Voltage Check1) Remove console box.
2) Check for voltage at each terminal with co nnectors connected to

Page 930 of 1496

SUZUKI SWIFT 2008 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine 6C-48 Power Assisted Steering System: 
Specifications
Tightening Torque SpecificationsS7RS0B6307001
NOTE
The specified tightening torque is als

Page 938 of 1496

SUZUKI SWIFT 2008 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine 7A-2 Heater and Ventilation: 
Schematic and Routing Diagram
Heater and Ventilation Wiring Circuit DiagramS7RS0B7102001
2. Ventilator duct 6. Fo

Page 942 of 1496

SUZUKI SWIFT 2008 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine 7A-6 Heater and Ventilation: 
Blower Motor Relay InspectionS7RS0B7106007
1) Remove junction block assembly referring to “BCM (Included in Jun

Page 944 of 1496

SUZUKI SWIFT 2008 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine 7A-8 Heater and Ventilation: 
b. Move temperature control lever (1) and air flow control plate (2) fully to the arrow direction. c. Fix tempera