PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Interpretation of faults
87B
87B-81
PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Interpretation of faults
87B
87B-81V9 MR-372-J84-87B000$301.mif
UCH
Vdiag No.: 44, 48,
4C, 4D, 4F, 50
DF011
CONTINUED
Check the condition and connection of the PE2 connector of the UCH (tabs bent, broken, oxidised, etc.).
If the connector is faulty and if there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector; otherwise, replace the wiring.
Check the continuity and insulation of the following connection:
●Connection code 14S between components 645 and 1415.
If the connection is faulty and if there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
If the fault is still present, contact the Techline.
2.DEF
NOTESNone.
Replace the sensor.
AFTER REPAIRCarry out another fault finding check on the system.
Clear the stored faults.
Deal with any other faults.
PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Interpretation of faults
87B
87B-84
PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Interpretation of faults
87B
87B-84V9 MR-372-J84-87B000$301.mif
UCH
Vdiag No.: 44, 48,
4C, 4D, 4F, 50
DF014
PRESENT
OR
STOREDCARD READER CIRCUIT
CC.0: Short circuit to earth
CO.0: Open circuit or short circuit to earth
CC.1: Short circuit to + 12 V
1.DEF: Internal electronic fault
NOTESConditions for applying the fault finding procedure to a stored fault:
Insert the card into the card reader, switch on and switch off the engine leaving the
card in the card reader. Carry out fault finding on the card reader circuit with the card
in the card reader (after the engine is switched off, the card reader is supplied and
controlled for 20 min).
Use Wiring Diagrams Technical Note for MEGANE II or SCENIC II.
CC.0
NOTESNone.
Check the condition and connection of the card reader connector (tabs bent, broken, oxidised, etc.).
If the connector is faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector; otherwise, replace the wiring.
Check the condition and connection of the PE2 and PE1 connectors of the UCH (tabs bent, broken, oxidised,
etc.).
If the connector is faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector; otherwise, replace the wiring.
Ensure the continuity and insulation from earth of the following connections:
●Connection code 26BG,
●Connection code 26BD,
●Connection code 26BH.
Between components 645 and 1082.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Using the oscilloscope, check for a square pulse signal on connection 26BH of the card reader connector:
Connect the oscilloscope between connection 26BH of the connector and a bodywork earth.
Set the oscilloscope as: Calibration at 5 V/division
Time base 100 ms/division
Check for a square pulse signal from the UCH on connection 26BH of the card reader connector.
If there is no signal, replace the UCH.
If there is a signal, replace the card reader.
If the fault is still present, contact the Techline.
AFTER REPAIRCarry out another fault finding check on the system.
Clear the stored faults.
Deal with any other faults.
UCH_V44_DF014 /UCH_V48_DF014/UCH_V4C_DF014/
UCH_V4D_DF014/UCH_V4F_DF014/UCH_V50_DF014
PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Interpretation of faults
87B
87B-85
PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Interpretation of faults
87B
87B-85V9 MR-372-J84-87B000$301.mif
UCH
Vdiag No.: 44, 48,
4C, 4D, 4F, 50
DF014
CONTINUED 1
CO.0
NOTESNone.
Check the condition and connection of the card reader connector (tabs bent, broken, oxidised, etc.).
If the connector is faulty and if there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector; otherwise, replace the wiring.
Check the condition and connection of the PE2 and PE1 connectors of the UCH (tabs bent, broken, oxidised,
etc.).
If the connector is faulty and if there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector; otherwise, replace the wiring.
Check for + 12 V on connection 26BH of the card reader.
Check for an earth on connection 26BK of the card reader.
If the connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Ensure the continuity and insulation from earth of the following connections:
●Connection code 26BG,
●Connection code 26BD,
●Connection code 26BH,
●Connection code 26BK.
Between components 645 and 1082.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Replace the card reader if necessary.
If the fault is still present, contact the Techline.
AFTER REPAIRCarry out another fault finding check on the system.
Clear the stored faults.
Deal with any other faults.
PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Interpretation of faults
87B
87B-86
PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Interpretation of faults
87B
87B-86V9 MR-372-J84-87B000$301.mif
UCH
Vdiag No.: 44, 48,
4C, 4D, 4F, 50
DF014
CONTINUED 2
CC.1
NOTESNone.
Check the condition and connection of the card reader connector (tabs bent, broken, oxidised, etc.).
If the connector is faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector; otherwise, replace the wiring.
Check the condition and connection of the PE2 and PE1 connectors of the UCH (tabs bent, broken, oxidised,
etc.).
If the connector is faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector; otherwise, replace the wiring.
Check for an earth on connection 26BK of the card reader.
If the connection is faulty and if there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
Check the insulation against + 12 V on the following connections:
●Connection code 26BG,
●Connection code 26BD,
●Connection code 26BK.
Between components 645 and 1082.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Replace the card reader if necessary.
If the fault is still present, contact the Techline.
1.DEF
NOTESNone.
Replace the card reader if necessary.
AFTER REPAIRCarry out another fault finding check on the system.
Clear the stored faults.
Deal with any other faults.
PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Interpretation of faults
87B
87B-91
PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Interpretation of faults
87B
87B-91V9 MR-372-J84-87B000$301.mif
UCH
Vdiag No.: 44, 48,
4C, 4D, 4F, 50
DF020
PRESENT
OR
STOREDFRONT INTERNAL AERIAL CIRCUIT
CO: Open circuit
NOTESConditions for applying the fault finding procedure to a stored fault:
Activation of command AC037: Transmitter aerial fault finding; if the fault becomes
present, then carry out this fault finding procedure.
Use Wiring Diagrams Technical Note for MEGANE II or SCENIC II.
Check the condition and connection of the front internal aerial connector (tabs bent, broken, etc.). If the
connector is faulty and if there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector; otherwise, replace the wiring.
Check the condition and connection of the PE3 connector of the UCH (tabs bent, broken, etc.).
If the connector is faulty and if there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector; otherwise, replace the wiring.
Check the insulation and continuity of the following connections:
●Connection code 26AT,
●Connection code 26AU.
Between components 645 and 1396.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Replace the aerial if necessary.
If the fault is still present, contact the Techline.
AFTER REPAIRCarry out another fault finding check on the system.
Clear the stored faults.
Deal with any other faults.
UCH_V44_DF020 /UCH_V48_DF020/UCH_V4C_DF020/
UCH_V4D_DF020/UCH_V4F_DF020/UCH_V50_DF020
PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Interpretation of faults
87B
87B-92
PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Interpretation of faults
87B
87B-92V9 MR-372-J84-87B000$301.mif
UCH
Vdiag No.: 44, 48,
4C, 4D, 4F, 50
DF021
PRESENT
OR
STOREDREAR INTERNAL AERIAL CIRCUIT
CO: Open circuit
NOTESConditions for applying the fault finding procedure to a stored fault:
Activation of command AC037: Transmitter aerial fault finding; if the fault becomes
present, then carry out this fault finding procedure.
Use Wiring Diagrams Technical Note for MEGANE II or SCENIC II.
Check the condition and connection of the rear internal aerial connector (tabs bent, broken, etc.).
If the connector is faulty and if there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector; otherwise, replace the wiring.
Check the condition and connection of the PE3 connector of the UCH (tabs bent, broken, etc.).
If the connector is faulty and if there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector; otherwise, replace the wiring.
Check the insulation and continuity of the following connections:
●Connection code 26AV,
●Connection code 26AW.
Between components 645 and 1397.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Replace the aerial if necessary.
If the fault is still present, contact the Techline.
AFTER REPAIRCarry out another fault finding check on the system.
Clear the stored faults.
Deal with any other faults.
UCH_V44_DF021 /UCH_V48_DF021/UCH_V4C_DF021/
UCH_V4D_DF021/UCH_V4F_DF021/UCH_V50_DF021
PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Interpretation of faults
87B
87B-93
PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Interpretation of faults
87B
87B-93V9 MR-372-J84-87B000$301.mif
UCH
Vdiag No.: 44, 48,
4C, 4D, 4F, 50
DF022
PRESENT
OR
STOREDCENTRE INTERNAL AERIAL CIRCUIT
CO: Open circuit
NOTESConditions for applying the fault finding procedure to a stored fault:
Activation of command AC037: Transmitter aerial fault finding; if the fault becomes
present, then carry out this fault finding procedure.
Use Wiring Diagrams Technical Note for MEGANE II or SCENIC II.
Check the condition and connection of the central internal aerial connector (tabs bent, broken, etc.).
If the connector is faulty and if there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector; otherwise, replace the wiring.
Check the condition and connection of the PE3 connector of the UCH (tabs bent, broken, etc.).
If the connector is faulty and if there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector; otherwise, replace the wiring.
Check the insulation and continuity of the following connections:
●Connection code 26AX,
●Connection code 26AY.
Between components 645 and 1398.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
AFTER REPAIRCarry out another fault finding check on the system.
Clear the stored faults.
Deal with any other faults.
UCH_V44_DF022 /UCH_V48_DF022/UCH_V4C_DF022/
UCH_V4D_DF022/UCH_V4F_DF022/UCH_V50_DF022
PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Interpretation of faults
87B
87B-94
PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Interpretation of faults
87B
87B-94V9 MR-372-J84-87B000$301.mif
UCH
Vdiag No.: 44, 48,
4C, 4D, 4F, 50
DF023
PRESENT
OR
STOREDDRIVER'S SIDE FRONT EXTERNAL AERIAL CIRCUIT
CO: Open circuit
NOTESConditions for applying the fault finding procedure to a stored fault:
Activation of command AC037: Transmitter aerial fault finding; if the fault becomes
present, then carry out this fault finding procedure.
Use Wiring Diagrams Technical Note for MEGANE II or SCENIC II.
Check the condition and connection of the driver's side front door external aerial connector (tabs bent, broken,
etc.).
If the connector is faulty and if there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector; otherwise, replace the wiring.
Check the condition and connection of the PE3 connector of the UCH (tabs bent, broken, etc.).
If the connector is faulty and if there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector; otherwise, replace the wiring.
Check the insulation and continuity of the following connections:
●Connection code 26AA,
●Connection code 26AB.
Between components 645 and 1374.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
AFTER REPAIRCarry out another fault finding check on the system.
Clear the stored faults.
Deal with any other faults.
UCH_V44_DF023 /UCH_V48_DF023/UCH_V4C_DF023/
UCH_V4D_DF023/UCH_V4F_DF023/UCH_V50_DF023