Page 93 of 107
17C-93
MR-372-J84-17C000$826.mif
V2
GAS INJECTION
Fault finding - Interpretation of commands
LPG 3000
Program No.
Vdiag No: 08/10
17C
AC018
CYLINDER INJECTOR NO. 4
NOTESWith ignition on and engine stopped.
Switch on the ignition and run command AC018.
If the injector does not vibrate 10 times, perform the fault finding procedure for DF087 Cylinder 4 injector circuit.
AFTER REPAIRRepeat the conformity check from the start.
GAZ3000_V08_AC018 / GAZ3000_V10_AC018
Page 94 of 107
17C-94
MR-372-J84-17C000$826.mif
V2
GAS INJECTION
Fault finding - Interpretation of commands
LPG 3000
Program No.
Vdiag No: 08/10
17C
AC019
CYLINDER INJECTOR NO. 3
NOTESWith ignition on and engine stopped.
Switch on the ignition and run command AC019.
If the injector does not vibrate 10 times, perform the fault finding procedure for DF088 Cylinder 3 injector circuit.
AFTER REPAIRRepeat the conformity check from the start.
GAZ3000_V08_AC019 / GAZ3000_V10_AC019
Page 95 of 107
17C-95
MR-372-J84-17C000$826.mif
V2
GAS INJECTION
Fault finding - Interpretation of commands
LPG 3000
Program No.
Vdiag No: 08/10
17C
AC020
CYLINDER 2 INJECTOR
NOTESWith ignition on and engine stopped.
Switch on the ignition and run command AC020.
If the injector does not vibrate 10 times, perform the fault finding procedure for DF081 Cylinder 2 injector circuit.
AFTER REPAIRRepeat the conformity check from the start.
GAZ3000_V08_AC020 / GAZ3000_V10_AC020
Page 96 of 107
17C-96
MR-372-J84-17C000$826.mif
V2
GAS INJECTION
Fault finding - Interpretation of commands
LPG 3000
Program No.
Vdiag No: 08/10
17C
AC021
CYLINDER INJECTOR NO. 1
NOTESWith ignition on and engine stopped.
Switch on the ignition and run command AC021.
If the injector does not vibrate 10 times, perform the fault finding procedure for DF098 Cylinder 1 injector circuit.
AFTER REPAIRRepeat the conformity check from the start.
GAZ3000_V08_AC021 / GAZ3000_V10_AC021
Page 97 of 107
17C-97
MR-372-J84-17C000$826.mif
V2
GAS INJECTION
Fault finding - Interpretation of commands
LPG 3000
Program No.
Vdiag No: 08/10
17C
AC024
LPG EXPANSION VALVE SOLENOID VALVE
NOTESWith ignition on and engine stopped.
Switch on the ignition and run command AC024.
If the LPG expansion valve solenoid valve does not click 10 times, follow the interpretation of fault DF103 LPG
expansion valve solenoid valve circuit.
AFTER REPAIRRepeat the conformity check from the start.
GAZ3000_V08_AC024 / GAZ3000_V10_AC024
Page 98 of 107
17C-98
MR-372-J84-17C000$885.mif
V2
17C
GAS INJECTION
Fault finding - Customer complaints
NOTESOnly check the customer complaint after performing a complete check with the fault
finding tool.
IMPORTANT
For any operation on a component of the LPG supply circuit, consult the safety
instructions (see 17D, LPG injection, Introduction).
NO DIALOGUE WITH THE COMPUTER ALP 1
LPG GAUGE FAULTSALP 2
THE ENGINE STALLS WHEN SWITCHED TO LPG MODE ALP 3
IDLE SPEED FAULTSALP 4
FAULTS WHILE DRIVINGALP 5
LPG LEAK
LPG LEAK WHEN REFILLING
THE TANKALP 6
LPG 3000
Program No.
Vdiag No: 08/10
MR-372-J84-17C000$885.mif
Page 103 of 107

17C-103
MR-372-J84-17C000$944.mif
V2
GAS INJECTION
Fault finding - Fault finding chart (ALP)
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
ALP 3 The engine stalls when switched to LPG mode
IMPORTANT
When carrying out an operation on an LPG supply circuit component, consult the safety instructions
(see 17D, Gas injection, Introduction, Safety instructions for all operations).
NOTESCheck that there is LPG in the tank.
Check the condition of the air filter.
Replace the filter if necessary.
Check that the LPG supply pipes are not pinched or crushed.
Replace the faulty pipes if necessary.
Check the expansion valve cooling circuit (see MR 364 Mechanics, 17D, LPG injection, Expansion valve).
Repair the circuit if necessary.
Measure the resistance between tracks 1 and 2 of the injectors.
Replace the injectors if their resistance value at approximately 20°C is not between:
0.77 Ω < R < 1.43 Ω
Check the following connections for insulation from earth, continuity and absence of extraneous
resistance:
Main relay track 5
Main relay track 5
Main relay track 5
Main relay track 5track 1of injector 1
track 1of injector 2
track 1of injector 3
track 1of injector 4
Check the insulation from + 12 V, the continuity and the absence of interference resistance of
the connections between:
LPG computer track G3
LPG computer track G4
LPG computer track H2
LPG Computer track H3track 2 of injector 1
track 2 of injector 2
track 2 of injector 3
track 2 of injector 4
If necessary, repair the defective connections.
AFTER REPAIRCheck using the diagnostic tool.
GAZ3000_V08_ALP3 / GAZ3000_V10_ALP3
Page 104 of 107
17C-104
MR-372-J84-17C000$944.mif
V2
GAS INJECTION
Fault finding - Fault finding chart (ALP)
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
ALP 3
CONTINUED
Test the operation of the injectors.
Run commands AC018 Cylinder 4 injector, AC019 Cylinder 3 injector, AC020 Cylinder 2 injector
and AC021 Cylinder 1 injector.
Run the engine in petrol mode.
Disconnect the LPG tank connector and switch to LPG mode.
Check for + 12 Von track 1 of the LPG tank relay connector.
Repair if necessary.
Check for earth on track 2 of the LPG tank relay connector.
Repair if necessary.
Measure the resistance between tracks A4 and A5 (for Mégane 2) or tracks 1 and 2 (for Logan) of the LPG
tank solenoid valve.
Replace the solenoid valve if the resistance value is not approximately 12.6 Ω.
AFTER REPAIRCheck using the diagnostic tool.