17C-101
MR-372-J84-17C000$944.mif
V2
GAS INJECTION
Fault finding - Fault finding chart (ALP)
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
ALP 2
CONTINUED 1
For Logan
IMPORTANT
When carrying out an operation on an LPG supply circuit component, consult the safety instructions
(see 17D, Gas injection, Introduction, Safety instructions for all operations).
NOTESAsk the customer if the problem always arises.
If it is not the case, do not replace the sensor, as it is not the cause.
Is the fault that the tank is not displaying full when it has just been filled with LPG?
Check that the tank has just been filled with LPG, otherwise refill it.
If the customer complaint is reproduced, continue fault finding.
If not, the fault does not always arise. Do not replace the sensor and deal
with the next customer complaint.
Disconnect the connector from the LPG tank sender and measure
the resistance between tracks A1 and A.
Replace the LPG tank sender if the resistance value is less than 5 kOhms,
because the sensor is incorrect.
If the fault is still present, contact the Techline.
Is the fault related to the LPG warning not being displayed when the tank is empty?
NOYES
YES
A
AFTER REPAIRCheck using the diagnostic tool.
17C-102
MR-372-J84-17C000$944.mif
V2
GAS INJECTION
Fault finding - Fault finding chart (ALP)
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
ALP 2
CONTINUED 2
Check that the tank is empty, otherwise empty it by going for a drive.
If the customer complaint is reproduced, continue fault finding.
If not, the fault does not always arise. Do not replace the sensor and deal with the next customer complaint.
Disconnect the connector from the LPG tank sender and measure the resistance between tracks A1 and A.
Replace the LPG tank sender if the resistance value is greater than 2.1 kOhms, because the sensor is incorrect.
If the fault is still present, contact the Techline.
A
YES
AFTER REPAIRCheck using the diagnostic tool.