ENGINE COMPARTMENT CONNECTION UNIT
Fault finding - Interpretation of faults87G
87G-24V7 MR-372-J84-87G050$330.mif
UPC
Vdiag No.: 48, 4C
DF012
PRESENT
OR
STOREDALTERNATOR
1.DEF: Alternator mechanical or electrical fault
NOTESConditions for applying the fault finding procedure to present faults:
The fault is declared present after the engine has been running for at least 1 minute.
Special note:
The fault illuminates the Battery and STOP warning lights on the instrument panel.
Use Wiring Diagrams Technical Note for Mégane II or Scénic II.
1.DEF
NOTESNone.
Check the fitting, condition and tension of the accessories drive belt.
Visually check that the alternator is not clogged.
Clean out the alternator cooling vents using an air gun.
Check the wiring, the connections and the earths (see Test no. 1 Wiring test).
If the connection is faulty and if there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring otherwise replace the wiring.
Run command AC014 Alternator regulation (see Interpretation of commands).
With the bonnet closed, start the engine.
Leave the engine to run for 2 minutes at idle speed.
If the fault is still present, replace the alternator (see MR 364 or MR 370 Mechanical, 16A, Starting - Charging,
Alternator: Removal - Refitting).
AFTER REPAIRErase the faults from the computer memory, switch the + after ignition supply off and
back on again and run another check using the diagnostic tool.
USM_V48_DF012/USM_V4C_DF012