Page 44 of 63

83A-44
MR-372-J84-83A000$819.mif
V8
INSTRUMENT PANEL
Fault finding - Interpretation of commands83A
TDB ph2 (EG/MG)
Prog Version: 04xx
Vdiag No.: 08, 0C
AC009
INSTRUMENT PANEL WARNING LIGHTS
NOTESThere must be no present or stored faults.
Activate the instrument panel warning lights using command AC009 Instrument panel warning lights.
The indicator lights are all on, check that the lights are correct.
Check the condition and connection of the instrument panel 24-track grey connector.
If there is a repair method (see Technical note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair) repair the wiring, otherwise replace it.
Check the condition and connection of the 4-track seat belt warning module black connector.
If there is a repair method (see Technical note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair) repair the wiring, otherwise replace it.
Check the insulation, continuity and the absence of interference resistance on the following connections:
Instrument panel grey connector, track 16 Track 3 of the seat belt warning module
connector
Instrument panel grey connector, track 23 Track 4 of the seat belt warning module
connector
Instrument panel grey connector, track 12 Track 1 of the seat belt warning module
connector
Instrument panel grey connector, track 11 Track 2 of the seat belt warning module
connector
If there is a repair method (see Technical note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair) repair the wiring, otherwise replace it.
If the fault is still present, contact Techline.
AFTER REPAIRRepeat the conformity check from the start.
Page 48 of 63

83A-48
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
V8 MR-372-J84-83A000$945.mif
83A
TDB ph2 (EG/MG)
Prog version: 04xx
Vdiag No.: 08, 0C
ALP 1No communication with the instrument panel.
The instrument panel does not light up.
NOTESOnly consult this customer complaint after a complete check with the diagnostic tool.
See Wiring Diagram Technical Note for Scénic II.
Look for possible damage to the wiring harness.
Check the connection and condition of the instrument panel connector, component code 247.
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the insulation, continuity and the absence of interference resistance of the following connections:
•BP79 between components 247 and 260,
•MAM (if left-hand drive) or MAN (if right-hand drive) between component 247 and the earth,
•153A between components 247 and 1232,
•153B between components 247 and 1232.
If the connection or connections are faulty and if there is a repair method (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
If the fault is still present, contact Techline.
TDB_V08_ALP1/TDB_V0C_ALP1
INSTRUMENT PANEL
Fault finding - Fault finding chart
Page 49 of 63

83A-49
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
V8 MR-372-J84-83A000$945.mif
INSTRUMENT PANEL
Fault finding - Fault finding chart83A
TDB ph2 (EG/MG)
Prog version: 04xx
Vdiag No.: 08, 0C
ALP 2 The fuel level indicator does not display full
NOTESThe fuel tank must be filled with the ignition switched off (advise the customer to remove
the key).
Ideally the customer must fill the tank with at least 15 litres.
See Wiring Diagram Technical Note for Scénic II.
Ask the customer if the tank is filled up under the
following conditions:
–the customer filled the tank up to the 3
rd cut-out
–the customer has changed filling station
–the customer filled the tank in a flat-level station (not
on a slope).
Did the customer fill the tank while observing all of
these conditions?Ask the customer to return just after
having filled the tank under the conditions
mentioned above.
NO
YES
A
TDB_V08_ALP2/TDB_V0C_ALP2