2008 INFINITI QX56 fl sensor

[x] Cancel search: fl sensor

Page 1688 of 4083

INFINITI QX56 2008  Factory Service Manual P2A00, P2A03 A/F SENSOR 1EC-389
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
10.CHECK INTERMITTENT INCIDENT
Perform  GI-35, "
How to Check Terminal" and GI-38, "Intermittent Incide

Page 1701 of 4083

INFINITI QX56 2008  Factory Service Manual EC-402
< COMPONENT DIAGNOSIS >[VK56DE]
FUEL PUMP
FUEL PUMP
DescriptionINFOID:0000000001365881
SYSTEM DESCRIPTION
*: ECM determines the start signal status by the signals of engine speed and battery vo

Page 1703 of 4083

INFINITI QX56 2008  Factory Service Manual EC-404
< COMPONENT DIAGNOSIS >[VK56DE]
FUEL PUMP
2. Disconnect 15A fuse.
3. Check 15A fuse.
OK or NG
OK >> GO TO 7.
NG >> Replace fuse.
7.CHECK CONDENSER-2 POWER SUPPLY 
CIRCUIT-II FOR OPEN AND SHORT

Page 1704 of 4083

INFINITI QX56 2008  Factory Service Manual FUEL PUMPEC-405
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
>> Repair open circuit or short to ground or short to power in harness or connectors.
12.CHECK FUEL PUMP
Refer to  EC-4

Page 1715 of 4083

INFINITI QX56 2008  Factory Service Manual EC-416
< COMPONENT DIAGNOSIS >[VK56DE]
ON BOARD REFUELING VAPOR RECOVERY (ORVR)
ON BOARD REFUELING VAPOR RECOVERY (ORVR)
System DescriptionINFOID:0000000001351317
From the beginning of refueling, the

Page 1716 of 4083

INFINITI QX56 2008  Factory Service Manual ON BOARD REFUELING VAPOR RECOVERY (ORVR)EC-417
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
Does water drain from
 the EVAP canister?
Ye s  o r  N o
Yes >> GO TO 3.
No >> GO TO 5.

Page 1722 of 4083

INFINITI QX56 2008  Factory Service Manual REFRIGERANT PRESSURE SENSOREC-423
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
REFRIGERANT PRESSURE SENSOR
Component DescriptionINFOID:0000000001365897
The refrigerant pressure sen

Page 1723 of 4083

INFINITI QX56 2008  Factory Service Manual EC-424
< COMPONENT DIAGNOSIS >[VK56DE]
REFRIGERANT PRESSURE SENSOR
Refer to EC-86, "Ground Inspection".
OK or NG
OK >> GO TO 3.
NG >> Repair or replace ground connections.
3.CHECK REFRIGERANT PRESSURE