6 - 6
–+ELECIGNITION SYSTEM
2. Inspect:
•Source coil 1 resistance
Out of specification → Replace.
3. Inspect:
•Source coil 2 resistance
Out of specification → Replace. Tester (+) lead
→ Brown lead
1
Tester (–) lead
→ Green lead
2
Source coil 1
resistanceTester selector
position
720 ~ 1,080
Ω at
20 °C (68 °F)Ω
× 100
Tester (+) lead
→ Pink lead
1
Tester (–) lead
→ Black lead
2
Source coil 2
resistanceTester selector
position
44 ~ 66
Ω at
20 °C (68 °F)Ω
× 10
W
RBr
GP
B
2 1
2
1
W
RBr
GP
B
NEUTRAL SWITCH INSPECTION
1. Inspect:
•Neutral switch conduct
No continuity while in neutral → Replace.
Continuity while in gear → Replace.
EC628000
CDI UNIT INSPECTION
Check all electrical components. If no fault is
found, replace the CDI unit. Then check the
electrical components again.Tester (+) lead
→ Sky blue lead
1
Tester (–) lead
→ Ground
2
Sb
1 Ground
2 Tester selec-
tor position
NEUTRAL
Ω
× 1
IN GEAR
–+ Ω×1
1
2
Sb
–+ELEC
6 - 7
TPS (THROTTLE POSITION SENSOR) SYSTEM
EC690000
TPS (THROTTLE POSITION SENSOR) SYSTEM
INSPECTION STEPS
If the TPS will not operate, use the following inspection steps.
*marked: Refer to “IGNITION SYSTEM” section.
NOTE:
Use the following special tools in this inspection.
Pocket tester:
YU-3112-C/90890-03112
Check entire ignition
system for connection.Repair or replace.
Check TPS. TPS coil Replace.
*Check CDI magneto. Source coil Replace.
Check CDI unit.TPS input
voltageReplace.
OK
OK
OK
No good
No good
No good
No good