2007 SUZUKI SWIFT intake valve

[x] Cancel search: intake valve

Page 326 of 1496

SUZUKI SWIFT 2007 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine 1D-41 Engine Mechanical: 
Valve head radial runout
Check each valve for radial runout with a dial gauge and 
“V” block. To check runout, ro

Page 327 of 1496

SUZUKI SWIFT 2007 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine Engine Mechanical:  1D-42
Cylinder Head InspectionS7RS0B1406027
• Remove all carbon deposits from combustion chambers.
NOTE
Do not use any sh

Page 340 of 1496

SUZUKI SWIFT 2007 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine 1D-55 Engine Mechanical: 
Installation
NOTE
• Use new bearing cap No.1 bolts. They are deformed once they are used because they 
are plastic

Page 349 of 1496

SUZUKI SWIFT 2007 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine Engine Mechanical:  1D-64
Honing or Reboring Cylinders1) When any cylinder needs reboring, all other  cylinders must also be rebored at the sam

Page 350 of 1496

SUZUKI SWIFT 2007 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine 1D-65 Engine Mechanical: 
NOTE
The specified tightening torque is also described in the following.
“Air Cleaner Components”
“Throttle Bod

Page 371 of 1496

SUZUKI SWIFT 2007 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine Engine Cooling System:  1F-8
Thermostat Removal and InstallationS7RS0B1606007
Removal1) Drain coolant referring to “Cooling System Draining

Page 377 of 1496

SUZUKI SWIFT 2007 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine Fuel System:  1G-2
Fuel Pump DescriptionS7RS0B1701003
The fuel pump (1) is an in-tank type electric pump. 
Incorporated in the pump assembly ar

Page 383 of 1496

SUZUKI SWIFT 2007 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine Fuel System:  1G-8
Installation1) Install clamps to marked location on pipes. If clamp  is deformed, its claw is bent  or broken, replace it wi