Page 92 of 139
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of statuses
23A
23A-92V5 MR-372-J84-23A100$580.mif
SIEMENS TA2005
Vdiag No.: 14-18
ET010
OIL TOO HOT SIGNAL
NOTESThere must be no present or stored faults.
This status means the oil temperature is above the normal operation temperature.
The status displays "NO" if the gearbox oil temperature is below 140 ˚C.
The status displays "YES" when the gearbox oil temperature rises above 140 ˚C.
If the correct status is not displayed, use the interpretation of fault DF177 "Automatic transmission
overheating".
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2005_V14_ET010/DP0TA2005_V18_ET010
Page 96 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of statuses
23A
23A-96V5 MR-372-J84-23A100$580.mif
SIEMENS TA2005
Vdiag No.: 14-18
* EV: Solenoid valve.ET020
EXCHANGER FLOW CONTROL SOLENOID VALVE*
NOTESThere must be no present or stored faults.
The exchanger flow control solenoid valve command status displays "ACTIVE" in the following conditions:
–gearbox oil temperature is above 100˚C,
–engine speed is greater than 2000 rpm.
With other conditions, the solenoid valve status displays "INACTIVE".
Disconnect the computer. Check the cleanliness and condition of the connectors.
Check the continuity of the following connections:
●connection code 5DD, between components 119 and 1019,
●connection code 5DN, between components 119 and 1019.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Measure the resistance of component 1019 between the following connections:
●connection code 5DD,
●connection code 5DN.
The value should be 40 Ω ± 2 at approximately 23 ˚C.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the resistance is greater than 50 Ω, check the wiring harness, computer connector and modular connector.
If the status of the command fails to change, use the interpretation of fault DF017 "Exchanger flow solenoid valve
circuit".
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2005_V14_ET020/DP0TA2005_V18_ET020
Page 97 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of statuses
23A
23A-97V5 MR-372-J84-23A100$580.mif
SIEMENS TA2005
Vdiag No.: 14-18
ET021
SEQUENCE SOLENOID VALVE 1 CONTROL
NOTESThere must be no present or stored faults.
This status displays "ACTIVE" when the gear engaged is "3" or "4" and "INACTIVE" when other gears are
engaged.
Disconnect the computer. Check the cleanliness and condition of the connectors.
Check the continuity between track 10 of the computer connector and track B8 of the modular connector.
Check the continuity of the following connections:
●connection code 5AV, between components 119 and 754.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Measure the resistance of component 754 between the following connections:
●connection code 5AV,
●connection code 5AU.
The value should be 40 Ω ± 2 at approximately 23 ˚C.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the resistance is greater than 50 Ω, check the wiring harness, computer connector and modular connector.
If the status does not function as specified, use the interpretation of fault DF085 "EVS1 Sequence solenoid valve
circuit".
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2005_V14_ET021/DP0TA2005_V18_ET021
Page 98 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of statuses
23A
23A-98V5 MR-372-J84-23A100$580.mif
SIEMENS TA2005
Vdiag No.: 14-18
ET022
SEQUENCE SOLENOID VALVE 2 CONTROL
NOTESThere must be no present or stored faults.
This status displays "ACTIVE" when the gear engaged is "N" or "2" or "3" or "4" and "INACTIVE" when other
gears are engaged.
Disconnect the computer. Check the cleanliness and condition of the connectors.
Check the continuity of the following connections:
●connection code 5AW, between components 119 and 754.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Measure the resistance of component 754 between the following connections:
●connection code 5AW,
●connection code 5AU.
The value should be 40 Ω ± 2 at approximately 23 ˚C.
If any of the connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring
repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the resistance is greater than 50 Ω, check the wiring harness, computer connector and modular connector.
If the status does not function as specified, use the interpretation of fault DF086 "EVS2 Sequence solenoid valve
circuit".
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2005_V14_ET022/DP0TA2005_V18_ET022
Page 99 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of statuses
23A
23A-99V5 MR-372-J84-23A100$580.mif
SIEMENS TA2005
Vdiag No.: 14-18
ET023
SEQUENCE SOLENOID VALVE 3 CONTROL
NOTESThere must be no present or stored faults.
This status displays "ACTIVE" when the gear engaged is "P" or "N" or "1" and "INACTIVE" when other gears
are engaged.
Disconnect the computer. Check the cleanliness and condition of the connectors.
Check the continuity of the following connections:
●connection code 5AX, between components 119 and 754.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Measure the resistance of component 754 between the following connections:
●connection code 5AX,
●connection code 5AU.
The value should be 40 Ω ± 2 at approximately 23 ˚C.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the resistance is greater than 50 Ω, check the wiring harness, the computer connector and the modular
connector.
If the status does not function as specified, use the interpretation of fault DF087 "EVS3 Sequence solenoid valve
circuit".
AFTER REPAIRRepeat the conformity check from the start.
Make sure that shifting up and down through each gear works properly.
DP0TA2005_V14_ET023/DP0TA2005_V18_ET023
Page 100 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of statuses
23A
23A -100V5 MR-372-J84-23A100$580.mif
SIEMENS TA2005
Vdiag No.: 14-18
ET024
SEQUENCE SOLENOID VALVE 4 CONTROL
NOTESThere must be no present or stored faults.
This status displays "ACTIVE" when the gear engaged is "1" or "2" and "INACTIVE" when other gears are
engaged.
Disconnect the computer. Check the cleanliness and condition of the connectors.
Check the continuity of the following connections:
●connection code 5AY, between components 119 and 754.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Measure the resistance of component 754 between the following connections:
●connection code 5AU,
●connection code 5AY.
The value should be 40 Ω ± 2 at approximately 23 ˚C.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the resistance is greater than 50 Ω, check the wiring harness, computer connector and modular connector.
If the status does not function as specified, use the interpretation of fault DF089 "EVS4 Sequence solenoid valve
circuit".
AFTER REPAIRRepeat the conformity check from the start.
Make sure that shifting up and down through each gear works properly.
DP0TA2005_V14_ET024/DP0TA2005_V18_ET024
Page 101 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of statuses
23A
23A -101V5 MR-372-J84-23A100$580.mif
SIEMENS TA2005
Vdiag No.: 14-18
ET025
SEQUENCE SOLENOID VALVE 5 CONTROL
NOTESThere must be no present or stored faults.
This status displays "ACTIVE" when the gear engaged is "1" and "INACTIVE" when other gears are engaged.
Disconnect the computer. Check the cleanliness and condition of the connectors.
Check the continuity of the following connections:
●connection code 5DL, between components 119 and 754.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Measure the resistance of component 754 between the following connections:
●connection code 5AU,
●connection code 5DL.
The value should be 40 Ω ± 2 at approximately 23 ˚C.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the resistance is greater than 50 Ω, check the wiring harness, computer connector and modular connector.
If the status is still not correct, use the interpretation of fault DF088 "EVS5 Sequence solenoid valve circuit".
AFTER REPAIRRepeat the conformity check from the start.
Make sure that shifting up and down through each gear works properly.
DP0TA2005_V14_ET025/DP0TA2005_V18_ET025
Page 102 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of statuses
23A
23A -102V5 MR-372-J84-23A100$580.mif
SIEMENS TA2005
Vdiag No.: 14-18
ET026
SEQUENCE SOLENOID VALVE 6 CONTROL
NOTESThere must be no present or stored faults.
This status displays "INACTIVE" with any gear engaged.
Disconnect the computer. Check the cleanliness and condition of the connectors.
Check the continuity of the following connections:
●connection code 5DM, between components 119 and 754.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Measure the resistance of component 754 between the following connections:
The value should be 40 Ω ± 2 at approximately 23 ˚C.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the resistance is greater than 50 Ω, check the wiring harness, computer connector and modular connector.
If the status is still not correct, use the interpretation of fault DF112 "EVS6 Sequence solenoid valve circuit".
AFTER REPAIRRepeat the conformity check from the start.
Make sure that shifting up and down through each gear works properly.
DP0TA2005_V14_ET026/DP0TA2005_V18_ET026