POWER ASSISTED STEERING
Fault finding - Conformity check
36B
36B - 25V6 MR-366-X84-36B000$528_eng.mif
PAS
Vdiag No.: 04, 06, 08, 0C
and 12POWER ASSISTED STEERING
Fault finding - Conformity check
MAIN SCREEN
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool.
The values shown in this conformity check are given as examples.
Execution conditions: ENGINE STOPPED, IGNITION ON.
Order FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
1Steering wheel
angleET020:Steering wheel
angle sensor
programmingStatus 4: calibrated
and initialisedIn the event of a fault, consult
the interpretation of status
ET020.
2EngineET023:Engine
operationSTOPPED: engine
stopped.
STALLED: engine
stopped without using
the ignition keyIn the event of a fault, test the
multiplex network.
3Computer
supplyPR108:Computer feed
voltage9 V < X < 16 VIf the computer supply
voltage is not sufficient,
dialogue cannot be
established.
If PR108 is not correct, run
fault finding on the charge
circuit.
4Vehicle speedPR003:Vehicle speed0 mph (0 km/h) when
stationaryIn the event of a fault, test the
multiplex network.
5Electric motorPR012:Current
absorbed by the
motor0 A < X < 1 AWithout any action on the
steering wheel.
6Thermal
protectionPR119:Motor thermal
protection
indicatorInterior temperature
± 5 ˚CIf PR119 > 60˚C, thermal
protection is activated.
The assistance level PR140
= 15 %. To deactivate
thermal protection, do not
operate the EPAS for
15 minutes. PR014:Level of
assistance
available99 % or 0 %
depending on Vdiag
15 % if thermal
protection activated.
DAETRW_V04_CCONF/DAETRW_V08_CCONF/DAETRW_V06_CCONF/DAETRW_V0C_CCONF