INFINITI FX35 2006  Service Manual DTC P0137, P0157 HO2S2 EC-271
[VQ35DE]
C 
D  E 
F 
G  H 
I 
J 
K  L 
M  A
EC 
Revision: 2006 December 2006 FX35/FX45
DTC Confirmation ProcedureNBS003U2
NOTE: 
If DTC confirmation Procedure has been pr

Page 1661 of 4462

INFINITI FX35 2006  Service Manual DTC P0137, P0157 HO2S2 EC-277
[VQ35DE]
C 
D  E 
F 
G  H 
I 
J 
K  L 
M  A
EC 
Revision: 2006 December 2006 FX35/FX45
2. CLEAR THE SELF-LEARNING DATA 
   With CONSULT-II 
1. Start engine and warm it up

Page 1662 of 4462

INFINITI FX35 2006  Service Manual EC-278
[VQ35DE]
DTC P0137, P0157 HO2S2
Revision: 2006 December 2006 FX35/FX45
4. CHECK HEATED OXYGEN SENSOR 2 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT 
1. Check harness continuity between ECM terminal

Page 1663 of 4462

INFINITI FX35 2006  Service Manual DTC P0137, P0157 HO2S2 EC-279
[VQ35DE]
C 
D  E 
F 
G  H 
I 
J 
K  L 
M  A
EC 
Revision: 2006 December 2006 FX35/FX45
6. Select “FUEL INJECTION” in “ACTIVE TEST” mode, and select  “HO2S2 (B1)

Page 1666 of 4462

INFINITI FX35 2006  Service Manual EC-282
[VQ35DE]
DTC P0138, P0158 HO2S2
Revision: 2006 December 2006 FX35/FX45
DTC Confirmation ProcedureNBS004M9
Perform PROCEDURE FOR MALFUNCTION A first. 
If DTC cannot be confirmed, perform PROCEDU

Page 1674 of 4462

INFINITI FX35 2006  Service Manual EC-290
[VQ35DE]
DTC P0138, P0158 HO2S2
Revision: 2006 December 2006 FX35/FX45
2. CLEAR THE SELF-LEARNING DATA 
   With CONSULT-II 
1. Start engine and warm it up to normal operating temperature.
2. Se

Page 1675 of 4462

INFINITI FX35 2006  Service Manual DTC P0138, P0158 HO2S2 EC-291
[VQ35DE]
C 
D  E 
F 
G  H 
I 
J 
K  L 
M  A
EC 
Revision: 2006 December 2006 FX35/FX45
4. CHECK HEATED OXYGEN SENSOR 2 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT 
1. Check h

Page 1676 of 4462

INFINITI FX35 2006  Service Manual EC-292
[VQ35DE]
DTC P0138, P0158 HO2S2
Revision: 2006 December 2006 FX35/FX45
6. Select “FUEL INJECTION” in “ACTIVE TEST” mode, and select “HO2S2 (B1)/(B2)” as the monitor item with CONSUL